Manuale per l’uso Bryant CONDENSING GAS FURNACE 340MAV

12 pagine 1.15 mb
Scarica

Vai alla pagina of 12

Summary
  • Bryant CONDENSING GAS FURNACE 340MAV - page 1

    USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance. — Do not touch any electrical switch; do not use any ph ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 2

    INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No . Model No . Serial No . INDOOR COIL: Product No . Model No . Serial No . WELCOME T O A NEW GENERA TION OF COMFOR T Congratulations! In light of rising energy costs, the Plus 90 TM , ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 3

    3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating. Redundant gas valve. Safe, efficient. Features 1 gas control with 2 inte ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 4

    4 IMPOR T ANT F A CTS Y our gas furnace uses air from outside the home for combustion and venting. It is not to be installed using in-house air . Therefore, both pipes must terminate outside the structure and must not be obstructed in any w ay . 5 T o minimize the possibility of serious personal injury , fi re, damage to your furnace, or improper ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 5

    5 a 8 9 10 2. Close the external manual g as v alve. (See Fig. 9.) 3. T urn of f electrical supply to the furnace. (See Fig. 10.) 4. Remov e the main furnace door . (See Fig. 11.) 5. Gas valve will ha ve EITHER a con- trol switch or control knob to turn OFF or ON. T urn control switch or knob on the gas v alve to the OFF position and wait 5 minutes ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 6

    6 16 17 18 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 19 O P E N ® 20 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting. (See Fig. 19.) 2. Close the external manual g as v alve. (See Fig. 9.) ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 7

    7 BLO WER COMP AR TMENT a. Remo ve main furnace door . (See Fig. 23) b . Remove blo wer access panel. (See Fig. 24) NO TE: It will be necessary to remov e 2 screws • AIR FIL TER LOCA TED IN FIL- TER CABINET a. Remo ve fi lter cabinet door (See Fig. 36 and 37) NO TE: It will be necessary to remov e 1 thumbscrew 3. Remov e air fi lter from furnac ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 8

    8 29 30 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Also check the comb ustion-air intake and vent pipes on the outside of your home for blockage. When dirt, soot, scale, o ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 9

    9 34 35 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over fi ll condensate trap, and fl ow into open fi eld drain. (See Fig. 35.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp. 9 . Replace main furnace door . (See Fig. 30.) A CHECK-UP CHECKLIST Y our f ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 10

    10 39 40 41 BEFORE Y OU REQUEST A SER VICE CALL If your furnace is not operating or not performing properly , you may sav e the expense of a service call by check- ing a fe w things yourself before calling for service. FOR INSUFFICIENT AIRFLOW : • Check for dirty air fi lter(s). • Check for blocked return-air or sup- ply-air grilles throughout ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 11

    11 MODEL 340MA V AND 350MA V DIA GNOSTIC CHAR T (See Fig. 3.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The fault code is a 2-digit n umber . The fi rst digit is determined by the number of short fl ashes of the light and the second digit is determined by number of long fl ashes of the light. F AUL T COD ...

  • Bryant CONDENSING GAS FURNACE 340MAV - page 12

    Cancels: OM05-30 OM05-32 © 2001 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5335-202 3-01 MODEL 355MA V DIA GNOSTIC CHAR T (See Fig. 4.) NO TES: 1. Red light 1 on continuously means furnace is operating in emergency heat. 2. Red light 2 on continuously means the microprocessor boa ...

Fabbricante Bryant Categoria Furnace

I documenti che otteniamo dal fabbricante del dispositivoBryant CONDENSING GAS FURNACE 340MAV possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso CONDENSING GAS FURNACE 340MAV
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant CONDENSING GAS FURNACE 340MAV
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant CONDENSING GAS FURNACE 340MAV.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant CONDENSING GAS FURNACE 340MAV, manuali di manutenzione, brevi manuali o manuali utente Bryant CONDENSING GAS FURNACE 340MAV. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant CONDENSING GAS FURNACE 340MAV.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant CONDENSING GAS FURNACE 340MAV, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant CONDENSING GAS FURNACE 340MAV dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant CONDENSING GAS FURNACE 340MAV.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant CONDENSING GAS FURNACE 340MAV - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant CONDENSING GAS FURNACE 340MAV, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant CONDENSING GAS FURNACE 340MAV che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant CONDENSING GAS FURNACE 340MAV - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant CONDENSING GAS FURNACE 340MAV
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant CONDENSING GAS FURNACE 340MAV
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant CONDENSING GAS FURNACE 340MAV in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant CONDENSING GAS FURNACE 340MAV?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant CONDENSING GAS FURNACE 340MAV con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant CONDENSING GAS FURNACE 340MAV è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)