USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance. — Do not touch any electrical switch; do not use any ph ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 2
INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No . Model No . Serial No . INDOOR COIL: Product No . Model No . Serial No . WELCOME T O A NEW GENERA TION OF COMFOR T Congratulations! In light of rising energy costs, the Plus 90 TM , ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 3
3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating. Redundant gas valve. Safe, efficient. Features 1 gas control with 2 inte ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 4
4 IMPOR T ANT F A CTS Y our gas furnace uses air from outside the home for combustion and venting. It is not to be installed using in-house air . Therefore, both pipes must terminate outside the structure and must not be obstructed in any w ay . 5 T o minimize the possibility of serious personal injury , fi re, damage to your furnace, or improper ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 5
5 a 8 9 10 2. Close the external manual g as v alve. (See Fig. 9.) 3. T urn of f electrical supply to the furnace. (See Fig. 10.) 4. Remov e the main furnace door . (See Fig. 11.) 5. Gas valve will ha ve EITHER a con- trol switch or control knob to turn OFF or ON. T urn control switch or knob on the gas v alve to the OFF position and wait 5 minutes ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 6
6 16 17 18 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 19 O P E N ® 20 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting. (See Fig. 19.) 2. Close the external manual g as v alve. (See Fig. 9.) ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 7
7 BLO WER COMP AR TMENT a. Remo ve main furnace door . (See Fig. 23) b . Remove blo wer access panel. (See Fig. 24) NO TE: It will be necessary to remov e 2 screws • AIR FIL TER LOCA TED IN FIL- TER CABINET a. Remo ve fi lter cabinet door (See Fig. 36 and 37) NO TE: It will be necessary to remov e 1 thumbscrew 3. Remov e air fi lter from furnac ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 8
8 29 30 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Also check the comb ustion-air intake and vent pipes on the outside of your home for blockage. When dirt, soot, scale, o ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 9
9 34 35 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over fi ll condensate trap, and fl ow into open fi eld drain. (See Fig. 35.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp. 9 . Replace main furnace door . (See Fig. 30.) A CHECK-UP CHECKLIST Y our f ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 10
10 39 40 41 BEFORE Y OU REQUEST A SER VICE CALL If your furnace is not operating or not performing properly , you may sav e the expense of a service call by check- ing a fe w things yourself before calling for service. FOR INSUFFICIENT AIRFLOW : • Check for dirty air fi lter(s). • Check for blocked return-air or sup- ply-air grilles throughout ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 11
11 MODEL 340MA V AND 350MA V DIA GNOSTIC CHAR T (See Fig. 3.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The fault code is a 2-digit n umber . The fi rst digit is determined by the number of short fl ashes of the light and the second digit is determined by number of long fl ashes of the light. F AUL T COD ...
-
Bryant CONDENSING GAS FURNACE 340MAV - page 12
Cancels: OM05-30 OM05-32 © 2001 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5335-202 3-01 MODEL 355MA V DIA GNOSTIC CHAR T (See Fig. 4.) NO TES: 1. Red light 1 on continuously means furnace is operating in emergency heat. 2. Red light 2 on continuously means the microprocessor boa ...