    1-800-K EA TI NG www .keatingofchicago.com Users Manual M I RA CLEAN ® EL EC T RIC GRIDDL E S E R I E S 2000 R EAD AN D SA VE TH I S MAN U AL F OR FUTUR E R E FE R E NCE. Keep this manual for training new personnel. G EN E RAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ST AN DARD FEA TUR E S . . ...

  • Keating Of Chicago 2000 - page 2

    i POST THIS LABEL IN A PR OMINENT L OCA TION ON Y OUR UNIT . W A RNIN G Do not store flammable liquids near this or any other appliance. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMA ...

  • Keating Of Chicago 2000 - page 3

    1 INTRODUCTION GENERAL Keating MIRACLEAN ® Electric Griddles are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated into Keating MIRACLEAN ® Electric Griddles. ST ANDARD FEA TURES  MIRACLEAN ® energy efficient plate  Welded st ainless steel perimeter  We ...

  • Keating Of Chicago 2000 - page 4

    2 II INST ALLA TION This unit must be installed, inspected, calibrated and serviced by qualified and/or certified and licensed service personnel - you may void your Keating warranty if installation is not completed per local, national and Keating specifications. Contact your dealer for assistance. INST ALLA TION Installation must conform with local ...

  • Keating Of Chicago 2000 - page 5

    3 pages 1 1 - 12 Wiring Diagram) to see if the griddle is connected three phase or single phase. All wires, cords, plugs, receptacles and circuit breakers must be sized adequately for the full load rating of the griddle as specified by local codes or , in the absence of local codes, by the current National Electrical Code ANSI/NFP A 70 or the Canad ...

  • Keating Of Chicago 2000 - page 6

    4 NOTE: Because of the superior heating characteristics and heat retention properties found in the MIRACLEAN ® Griddle, operating temperatures should be set 10°F to 25°F below conventional griddles. 3. Locate the inverted “V’s” on the front of the griddle cooking plate. Depending on your model you may have from one to six thermostat s. The ...

  • Keating Of Chicago 2000 - page 7

    5 CLEANING THE GRIDDLE The surface of the MIRACLEAN ® Griddle is very durable and with proper care, following the procedures below , will last many years. A sample of Keating Klenzer , Keating palmetto brush and a 4” scraper are included with each new griddle. 1. Scrape MIRACLEAN ® surface with the Keating Scraper . 2. Clean with potable t ap w ...

  • Keating Of Chicago 2000 - page 8

    6 A. Griddle Surface With proper care, the MIRACLEAN ® surface and its unique cooking properties will last for many years. However , nicks or dent s in the griddle surface may cause the griddle surface to lift from the depressed area. If nicks are close together , the surface may raise and be torn when a spatula or scraper is used. Care should be ...

  • Keating Of Chicago 2000 - page 9

    7 V SER VICE DIAGNOSIS A. T rouble shooting The following diagnosis is only to be used as a guide to qualified personnel. Keating recommends that you use a qualified service company . Call 1-800-KEA TING if you need assist ance in locating a qualified service company . PROBLEM PROBABLE CAUSE SOLUTION Griddle won't heat. a No electricity to gri ...

  • Keating Of Chicago 2000 - page 10

    D 052505 Grease Drawer (Not Shown) 8 VI P ARTS LIST ORDERING P ARTS Parts may be ordered by calling 1-800-KEA TING or your local Keating service company . Y ou may also order on- line at Keating’s p art store, www .keatingofchicago.com Refer to the Keating MIRACLEAN ® Electric Griddle Limited W arranty for complete service and ordering informati ...

  • Keating Of Chicago 2000 - page 11

    9 T o replace thermostat: • Loosen nut s (#7) • Loosen nut s to Dispersion Plate (if needed) • Slide thermost at bulb through slots pictured in items 2, 3, & 4. • With bulb tight against the plate, tighten all nuts. Figure 6-3 Heating Element Assembly ITEM DESCRIPTION P ART NUMBER QTY 24" DEEP QTY 30" DEEP QTY 33" DEEP 1 ...

  • Keating Of Chicago 2000 - page 12

    10 Assembly instructions for griddle st and on casters (There is no top on this stand) ...

  • Keating Of Chicago 2000 - page 13

    11 208 - 240 VOL T WIRING DIAGRAM (3-PHASE CONNECTIONS) ...

  • Keating Of Chicago 2000 - page 14

    208 - 240 VOL T WIRING DIAGRAM (SINGLE-PHASE CONNECTIONS) 12 ...

  • Keating Of Chicago 2000 - page 15

    13 480 VOL T WIRING DIAGRAM NOTE: Griddles rated at 480 V olts use type D-1 thermostats which include On/Of f switches. Separate On/Of f switches are not provided with these griddles. ...

  • Keating Of Chicago 2000 - page 16

    14 VIII KEA TING GRIDDLE SPECIFICA TIONS 24" DEEP MODELS 27x24 30x24 36x24 AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 4.1 10 17 10 20 220 4.6 1 1 18 1 1 21 240 5.5 1 1 20 1 1 23 AMPS PER LINE-THREE PHASE  2 ELEMENTS (2300 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 6.2 17 17 17 30 220 6.9 18 18 18 31 240 8.2 20 20 20 34 AMPS PER LINE-THR ...

  • Keating Of Chicago 2000 - page 17

    15 30" DEEP MODELS AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 5.4 13 22 13 26 220 6.0 14 24 14 27 240 7.1 15 26 15 30 AMPS PER LINE-THREE PHASE  2 ELEMENTS (3000 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 8.0 22 22 22 39 220 9.0 24 24 24 41 240 10.7 26 26 26 45 AMPS PER LINE-THREE PHASE  3 ELEMENTS (3000 W EACH) AMPS VOL TS kW SINGLE ...

  • Keating Of Chicago 2000 - page 18

    16 36" DEEP MODELS AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 10.1 28 28 28 48 220 1 1.3 30 30 30 51 240 13.4 32 32 32 56 AMPS PER LINE-THREE PHASE  3 ELEMENTS (3750 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 13.4 43 43 28 65 220 15.0 45 45 30 68 240 17.9 49 49 32 75 AMPS PER LINE-THREE PHASE  4 ELEMENTS (3750 W EACH) AMPS VOL TS kW ...

  • Keating Of Chicago 2000 - page 19

    ...

  • Keating Of Chicago 2000 - page 20

    SER VICE INFORMA TION If you hav e a service related question call 1-800-KEA TING. Please state the nature of the call; it will ensure speaking with the appropriate person. Hav e your serial and model number av ailable when ordering parts. KEA TING OF CHICA GO, INC. 8901 W . 50th Street, McCook, Illinios 60525-6001 Phone: (708) 246-3000 F AX: (708) ...

Fabbricante Keating Of Chicago Categoria Gas Heater

I documenti che otteniamo dal fabbricante del dispositivoKeating Of Chicago 2000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Keating Of Chicago
- manuali per l’uso 2000
- schede prodotto Keating Of Chicago
- opuscoli
- o etichette energetiche Keating Of Chicago 2000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Keating Of Chicago 2000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Keating Of Chicago 2000, manuali di manutenzione, brevi manuali o manuali utente Keating Of Chicago 2000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Keating Of Chicago 2000.

Manuale completo del dispositivo Keating Of Chicago 2000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Keating Of Chicago 2000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Keating Of Chicago 2000.

Il manuale per l’uso completo Keating Of Chicago, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Keating Of Chicago 2000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Keating Of Chicago 2000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Keating Of Chicago 2000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Keating Of Chicago 2000 - che ci dovrebbe aiutare nei primi passi durante l'uso Keating Of Chicago 2000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Keating Of Chicago 2000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Keating Of Chicago 2000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Keating Of Chicago 2000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Keating Of Chicago 2000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Keating Of Chicago 2000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)