    1-800-K EA TI NG www .keatingofchicago.com Users Manual M I RA CLEAN ® EL EC T RIC GRIDDL E S E R I E S 2000 R EAD AN D SA VE TH I S MAN U AL F OR FUTUR E R E FE R E NCE. Keep this manual for training new personnel. G EN E RAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ST AN DARD FEA TUR E S . . ...

  • Keating Of Chicago 2000 - page 2

    i POST THIS LABEL IN A PR OMINENT L OCA TION ON Y OUR UNIT . W A RNIN G Do not store flammable liquids near this or any other appliance. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMA ...

  • Keating Of Chicago 2000 - page 3

    1 INTRODUCTION GENERAL Keating MIRACLEAN ® Electric Griddles are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated into Keating MIRACLEAN ® Electric Griddles. ST ANDARD FEA TURES  MIRACLEAN ® energy efficient plate  Welded st ainless steel perimeter  We ...

  • Keating Of Chicago 2000 - page 4

    2 II INST ALLA TION This unit must be installed, inspected, calibrated and serviced by qualified and/or certified and licensed service personnel - you may void your Keating warranty if installation is not completed per local, national and Keating specifications. Contact your dealer for assistance. INST ALLA TION Installation must conform with local ...

  • Keating Of Chicago 2000 - page 5

    3 pages 1 1 - 12 Wiring Diagram) to see if the griddle is connected three phase or single phase. All wires, cords, plugs, receptacles and circuit breakers must be sized adequately for the full load rating of the griddle as specified by local codes or , in the absence of local codes, by the current National Electrical Code ANSI/NFP A 70 or the Canad ...

  • Keating Of Chicago 2000 - page 6

    4 NOTE: Because of the superior heating characteristics and heat retention properties found in the MIRACLEAN ® Griddle, operating temperatures should be set 10°F to 25°F below conventional griddles. 3. Locate the inverted “V’s” on the front of the griddle cooking plate. Depending on your model you may have from one to six thermostat s. The ...

  • Keating Of Chicago 2000 - page 7

    5 CLEANING THE GRIDDLE The surface of the MIRACLEAN ® Griddle is very durable and with proper care, following the procedures below , will last many years. A sample of Keating Klenzer , Keating palmetto brush and a 4” scraper are included with each new griddle. 1. Scrape MIRACLEAN ® surface with the Keating Scraper . 2. Clean with potable t ap w ...

  • Keating Of Chicago 2000 - page 8

    6 A. Griddle Surface With proper care, the MIRACLEAN ® surface and its unique cooking properties will last for many years. However , nicks or dent s in the griddle surface may cause the griddle surface to lift from the depressed area. If nicks are close together , the surface may raise and be torn when a spatula or scraper is used. Care should be ...

  • Keating Of Chicago 2000 - page 9

    7 V SER VICE DIAGNOSIS A. T rouble shooting The following diagnosis is only to be used as a guide to qualified personnel. Keating recommends that you use a qualified service company . Call 1-800-KEA TING if you need assist ance in locating a qualified service company . PROBLEM PROBABLE CAUSE SOLUTION Griddle won't heat. a No electricity to gri ...

  • Keating Of Chicago 2000 - page 10

    D 052505 Grease Drawer (Not Shown) 8 VI P ARTS LIST ORDERING P ARTS Parts may be ordered by calling 1-800-KEA TING or your local Keating service company . Y ou may also order on- line at Keating’s p art store, www .keatingofchicago.com Refer to the Keating MIRACLEAN ® Electric Griddle Limited W arranty for complete service and ordering informati ...

  • Keating Of Chicago 2000 - page 11

    9 T o replace thermostat: • Loosen nut s (#7) • Loosen nut s to Dispersion Plate (if needed) • Slide thermost at bulb through slots pictured in items 2, 3, & 4. • With bulb tight against the plate, tighten all nuts. Figure 6-3 Heating Element Assembly ITEM DESCRIPTION P ART NUMBER QTY 24" DEEP QTY 30" DEEP QTY 33" DEEP 1 ...

  • Keating Of Chicago 2000 - page 12

    10 Assembly instructions for griddle st and on casters (There is no top on this stand) ...

  • Keating Of Chicago 2000 - page 13

    11 208 - 240 VOL T WIRING DIAGRAM (3-PHASE CONNECTIONS) ...

  • Keating Of Chicago 2000 - page 14

    208 - 240 VOL T WIRING DIAGRAM (SINGLE-PHASE CONNECTIONS) 12 ...

  • Keating Of Chicago 2000 - page 15

    13 480 VOL T WIRING DIAGRAM NOTE: Griddles rated at 480 V olts use type D-1 thermostats which include On/Of f switches. Separate On/Of f switches are not provided with these griddles. ...

  • Keating Of Chicago 2000 - page 16

    14 VIII KEA TING GRIDDLE SPECIFICA TIONS 24" DEEP MODELS 27x24 30x24 36x24 AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 4.1 10 17 10 20 220 4.6 1 1 18 1 1 21 240 5.5 1 1 20 1 1 23 AMPS PER LINE-THREE PHASE  2 ELEMENTS (2300 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 6.2 17 17 17 30 220 6.9 18 18 18 31 240 8.2 20 20 20 34 AMPS PER LINE-THR ...

  • Keating Of Chicago 2000 - page 17

    15 30" DEEP MODELS AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 5.4 13 22 13 26 220 6.0 14 24 14 27 240 7.1 15 26 15 30 AMPS PER LINE-THREE PHASE  2 ELEMENTS (3000 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 8.0 22 22 22 39 220 9.0 24 24 24 41 240 10.7 26 26 26 45 AMPS PER LINE-THREE PHASE  3 ELEMENTS (3000 W EACH) AMPS VOL TS kW SINGLE ...

  • Keating Of Chicago 2000 - page 18

    16 36" DEEP MODELS AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 10.1 28 28 28 48 220 1 1.3 30 30 30 51 240 13.4 32 32 32 56 AMPS PER LINE-THREE PHASE  3 ELEMENTS (3750 W EACH) AMPS VOL TS kW SINGLE L1 L2 L3 PHASE 208 13.4 43 43 28 65 220 15.0 45 45 30 68 240 17.9 49 49 32 75 AMPS PER LINE-THREE PHASE  4 ELEMENTS (3750 W EACH) AMPS VOL TS kW ...

  • Keating Of Chicago 2000 - page 19

    ...

  • Keating Of Chicago 2000 - page 20

    SER VICE INFORMA TION If you hav e a service related question call 1-800-KEA TING. Please state the nature of the call; it will ensure speaking with the appropriate person. Hav e your serial and model number av ailable when ordering parts. KEA TING OF CHICA GO, INC. 8901 W . 50th Street, McCook, Illinios 60525-6001 Phone: (708) 246-3000 F AX: (708) ...

Manufacturer Keating Of Chicago Category Gas Heater

Documents that we receive from a manufacturer of a Keating Of Chicago 2000 can be divided into several groups. They are, among others:
- Keating Of Chicago technical drawings
- 2000 manuals
- Keating Of Chicago product data sheets
- information booklets
- or energy labels Keating Of Chicago 2000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Keating Of Chicago 2000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Keating Of Chicago 2000, service manual, brief instructions and user manuals Keating Of Chicago 2000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Keating Of Chicago 2000.

A complete manual for the device Keating Of Chicago 2000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Keating Of Chicago 2000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Keating Of Chicago 2000.

A complete Keating Of Chicago manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Keating Of Chicago 2000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Keating Of Chicago 2000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Keating Of Chicago 2000, that we can find in the current document
3. Tips how to use the basic functions of the device Keating Of Chicago 2000 - which should help us in our first steps of using Keating Of Chicago 2000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Keating Of Chicago 2000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Keating Of Chicago 2000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Keating Of Chicago 2000?

Use the form below

If you did not solve your problem by using a manual Keating Of Chicago 2000, ask a question using the form below. If a user had a similar problem with Keating Of Chicago 2000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)