    www .zephyronline.com Guide dutilisation, dentretien et dinst allation Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Num éro de sér ie: _____________________________________ Número de serie: Date of Purchase: Date dac hat: __________________ ...

  • Zephyr EOT-E42ASX - page 2

    2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALL A TION MUST COMPL Y WITH A LL LOCAL CODES. IMP ORT AN T : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Safety W arning: T urn ...

  • Zephyr EOT-E42ASX - page 3

    3 www .zephyronline.com T able of Content s Important safet y Notic e ..................................................................... 4 Electrical & Installa tion requi rements .............................................. 5 Electrical req uirements .......................... .................................... 5 Before installing the h ...

  • Zephyr EOT-E42ASX - page 4

    4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the manuf ...

  • Zephyr EOT-E42ASX - page 5

    5 www .zephyronline.com Electrical & Installation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer  s responsibility:  T o co ntact a qualified electrical inst al le r .  T o assure t hat the electrical inst allation is adequate and in conformance with National Electrical C ...

  • Zephyr EOT-E42ASX - page 6

    6 List of Materials PARTS SUPPLIED:  Blower unit housing  Hood canopy  Met al filter x 1  Halogen light bulb x 4  Upper and lower Duct covers x 4  Chimney structure  Hardware Packet: Allen spanner x 1 Te m p l a t e Use, Care and Installation guide Nu ts x 12 7x45 screws x 6 4 x 6 screws x 12 (to assemble duct covers) 3,5x6,5 s ...

  • Zephyr EOT-E42ASX - page 7

    7 www .zephyronline.com Dimensions and clearances ...

  • Zephyr EOT-E42ASX - page 8

    8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any ev entual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting version ). Sh ...

  • Zephyr EOT-E42ASX - page 9

    9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4  x 10 Rect., straight 6  Round,, straight 7", 8 Round,, straight 3 1/4  x 10 Rect.90° elbow 3 1/4  x 10 Rect.45° elbow 3 1/4  x 10 Rect.90° flat elbow 3 1/4  x 10 Rect. wall cap with damper 3 1/4  x 10 Rect.to 6  round trans ...

  • Zephyr EOT-E42ASX - page 10

    10 1. Pre-installation calculations 1" 3/8 K C (36" std) P S H a) Select a hood preference height P that is comfort able for the user . (from 24 to 32). b) Calculate Hood height your installation H = K-C-P . c) Conf irm t hat H i s with in th e rang e of mi n to m ax H found for your model (see Dimensions and clearances p arag ...

  • Zephyr EOT-E42ASX - page 11

    11 www .zephyronline.com c. Install a 8 exhaust duct and extend length = S - 16 5/8 from ceiling. Duct shall be securely fastened to joist s. Do not use duct smaller than specified. Attention: Duct inst allation is not required for non- vented (recirculating) inst allations d. Install 1/2" electrical conduit in location marked on templat ...

  • Zephyr EOT-E42ASX - page 12

    12 8. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO ...

  • Zephyr EOT-E42ASX - page 13

    13 www .zephyronline.com d. Fasten the canopy with 1 1 screws from the bottom. Bottom Vie w FRONT FRONT FRONT 12. Fix 6 nuts on the internal side of top duct covers sections (squere slots) and fix each other with 6 screws (3 per side). Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13. Install top duct covers assembl ...

  • Zephyr EOT-E42ASX - page 14

    14 14. Fix 6 nuts on the internal side of rear bottom duct covers section (square slot s - see drawings afte r step 1 1) and place it on the rear side of the hood on top the canopy , cheack that it snaps with top duct covers assembly . rear bottom duct covers section Plan diagram top view rear bottom duct covers section (snap into place) 15. Fit th ...

  • Zephyr EOT-E42ASX - page 15

    15 www .zephyronline.com 17. Assemble the lower (narrow) trim strips to the lower vent cover assembly . Cut the upper (wide) trim strips to length to fit the upper duct cover assembly . Assemble the upper trim strips to the upper duct cover assembly . Upper tab Lower tab Lower tab X X Upper tab 18. Check all light bulbs to mak e sure they are secur ...

  • Zephyr EOT-E42ASX - page 16

    16 Description of t he hood & Controls 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps m ay v ar y) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) CONTROLS Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hoo ...

  • Zephyr EOT-E42ASX - page 17

    17 www .zephyronline.com Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergent s. Warning: Failure to carry out th ...

  • Zephyr EOT-E42ASX - page 18

    18 T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector is not connecting p ...

  • Zephyr EOT-E42ASX - page 19

    19 www .zephyronline.com W arranty T O OBT AIN SERVICE UNDER WARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obt ain ser vic e under the warranty . T O OB T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please keep ...

  • Zephyr EOT-E42ASX - page 20

    20 List of Part s and Accessories Part Description Part# halogen bulb, 12V 20 W metal filter Part Description Part# Ductless recirculating kit charcoal replacement filter duct cover extension kit internal blower - 600 cfm in-line blower - 1 100 cfm ZRC-00AL EBI-600A EB N-1 100A Z0B-0013 Z0F-C060 Z1C-00AL ...

  • Zephyr EOT-E42ASX - page 21

    21 www .zephyronline.com ...

  • Zephyr EOT-E42ASX - page 22

    22 ...

Fabbricante Zephyr Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoZephyr EOT-E42ASX possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Zephyr
- manuali per l’uso EOT-E42ASX
- schede prodotto Zephyr
- opuscoli
- o etichette energetiche Zephyr EOT-E42ASX
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Zephyr EOT-E42ASX.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Zephyr EOT-E42ASX, manuali di manutenzione, brevi manuali o manuali utente Zephyr EOT-E42ASX. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Zephyr EOT-E42ASX.

Manuali per l’uso simili

Manuale completo del dispositivo Zephyr EOT-E42ASX, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Zephyr EOT-E42ASX dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Zephyr EOT-E42ASX.

Il manuale per l’uso completo Zephyr, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Zephyr EOT-E42ASX - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Zephyr EOT-E42ASX, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Zephyr EOT-E42ASX che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Zephyr EOT-E42ASX - che ci dovrebbe aiutare nei primi passi durante l'uso Zephyr EOT-E42ASX
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Zephyr EOT-E42ASX
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Zephyr EOT-E42ASX in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Zephyr EOT-E42ASX?

Utilizza il modulo sottostante

Se non hai risolto il problema con Zephyr EOT-E42ASX con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr EOT-E42ASX è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)