    www .zephyronline.com Glide EGL-E30AS EGL-E36AS Guide d’utilisation, d’entretien et d’inst allation Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ Número de serie: Date of Purchase: Date d’a ...

  • Zephyr EGL-E36AS - page 2

    2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local Electrical Inspector ’ s use. INST ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please retain these instructions for future reference. Safety W arning: T urn off ...

  • Zephyr EGL-E36AS - page 3

    3 www .zephyronline.com T able of Contents Important safety Notice ..................................................................... 4 Electrical & Inst allation requirements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ... ...

  • Zephyr EGL-E36AS - page 4

    4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the manufactu ...

  • Zephyr EGL-E36AS - page 5

    5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: • T o contact a qualified electrical inst aller . • T o assure that the electrical installation is adequate and in conformance with National Electrical Code, A ...

  • Zephyr EGL-E36AS - page 6

    6 List of Materials PARTS SUPPLIED: • Blower unit housing • Hood canopy • Metal filter x 1 • Halogen light bulb x 2 • Hardware Packet: Transition Allen spanner x 1 Lower bracket x 2 Upper Bracket x 2 Use, Care and Installation guide T emplate Cloth 2,9x9,5 screws x 2 (to fix the transition) 4,5x16 screws x 4 (2 to fix the drawer to the bo ...

  • Zephyr EGL-E36AS - page 7

    7 www .zephyronline.com 21" 9" 1/16 9" 13/16 15/16" - 1" 3/4 30"-36" 2" 3/4 9" 13/16 Dimensions and clearances Cut out for venting system and conduit 1" 1/4 1" 1/4 9" 1/4 23" 5/16 10" 21" 3/4 7" 1/16 3" 3/8 13/16" 13/16" Cut out for blower unit housing pa ...

  • Zephyr EGL-E36AS - page 8

    8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting version ). Sho ...

  • Zephyr EGL-E36AS - page 9

    9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4 ” x 10” Rect., straight 6 ” Round,, straight 7", 8” Round,, straight 3 1/4 ” x 10” Rect.90° elbow 3 1/4 ” x 10” Rect.45° elbow 3 1/4 ” x 10” Rect.90° flat elbow 3 1/4 ” x 10” Rect. wall cap with damper 3 1/4 ” x 10” Rect.to 6 ” round trans ...

  • Zephyr EGL-E36AS - page 10

    10 Inst allation 1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and ...

  • Zephyr EGL-E36AS - page 11

    11 www .zephyronline.com 8. Fit the blower unit housing inside the cabinet through the bottom opening. Check that fixing springs goes over the bottom panel.. Bottom opening Bottom panel Fixing springs 9. Apply two brackets (one per side) to the blower unit housing......... Upper bracket ....... lock in place (check that each bracket , once in posit ...

  • Zephyr EGL-E36AS - page 12

    12 ..... tighten securely the two screws on upper brackets, check that blower housing is now well blocked, then, from the inside of the hood, fix definitively the lower brackets with one screw each. Adjusting screws Upper + lower bracket definitive fixing screws 10. Refinish the installation to cabinet with two fixing screws. Final fixing screw Fin ...

  • Zephyr EGL-E36AS - page 13

    13 www .zephyronline.com 12. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GR ...

  • Zephyr EGL-E36AS - page 14

    14 Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps may vary) 5 Sliding Glass 6 Hood canopy 6 1 2 3 4 5 ...

  • Zephyr EGL-E36AS - page 15

    15 www .zephyronline.com Controls Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking. Description of control panel: A B C D E F A- ...

  • Zephyr EGL-E36AS - page 16

    16 Maintenance CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use the supplied cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks. Therefore ...

  • Zephyr EGL-E36AS - page 17

    17 www .zephyronline.com T rouble Shooting After inst allation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector ...

  • Zephyr EGL-E36AS - page 18

    18 W arranty T O OBT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty . T O OBT AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please keep a copy of your dated pro ...

  • Zephyr EGL-E36AS - page 19

    19 www .zephyronline.com List of Part and Accessories Part Description Part# halogen bulb, 12V 20 W metal filter Part Description Part# Ductless Recirculating Kit charcoal replacement filter Z0B-0013 ZRC-00GL Z0F-C063 remote control GF02ZA ...

  • Zephyr EGL-E36AS - page 20

    20 ...

  • Zephyr EGL-E36AS - page 21

    21 www .zephyronline.com ...

Fabbricante Zephyr Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoZephyr EGL-E36AS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Zephyr
- manuali per l’uso EGL-E36AS
- schede prodotto Zephyr
- opuscoli
- o etichette energetiche Zephyr EGL-E36AS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Zephyr EGL-E36AS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Zephyr EGL-E36AS, manuali di manutenzione, brevi manuali o manuali utente Zephyr EGL-E36AS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Zephyr EGL-E36AS.

Manuali per l’uso simili

Manuale completo del dispositivo Zephyr EGL-E36AS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Zephyr EGL-E36AS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Zephyr EGL-E36AS.

Il manuale per l’uso completo Zephyr, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Zephyr EGL-E36AS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Zephyr EGL-E36AS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Zephyr EGL-E36AS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Zephyr EGL-E36AS - che ci dovrebbe aiutare nei primi passi durante l'uso Zephyr EGL-E36AS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Zephyr EGL-E36AS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Zephyr EGL-E36AS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Zephyr EGL-E36AS?

Utilizza il modulo sottostante

Se non hai risolto il problema con Zephyr EGL-E36AS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr EGL-E36AS è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)