Zephyr EGL-E36ASの取扱説明書

21ページ 0.44 mb
ダウンロード

ページに移動 of 21

Summary
  • Zephyr EGL-E36AS - page 1

    www .zephyronline.com Glide EGL-E30AS EGL-E36AS Guide d’utilisation, d’entretien et d’inst allation Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ Número de serie: Date of Purchase: Date d’a ...

  • Zephyr EGL-E36AS - page 2

    2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local Electrical Inspector ’ s use. INST ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please retain these instructions for future reference. Safety W arning: T urn off ...

  • Zephyr EGL-E36AS - page 3

    3 www .zephyronline.com T able of Contents Important safety Notice ..................................................................... 4 Electrical & Inst allation requirements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ... ...

  • Zephyr EGL-E36AS - page 4

    4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the manufactu ...

  • Zephyr EGL-E36AS - page 5

    5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: • T o contact a qualified electrical inst aller . • T o assure that the electrical installation is adequate and in conformance with National Electrical Code, A ...

  • Zephyr EGL-E36AS - page 6

    6 List of Materials PARTS SUPPLIED: • Blower unit housing • Hood canopy • Metal filter x 1 • Halogen light bulb x 2 • Hardware Packet: Transition Allen spanner x 1 Lower bracket x 2 Upper Bracket x 2 Use, Care and Installation guide T emplate Cloth 2,9x9,5 screws x 2 (to fix the transition) 4,5x16 screws x 4 (2 to fix the drawer to the bo ...

  • Zephyr EGL-E36AS - page 7

    7 www .zephyronline.com 21" 9" 1/16 9" 13/16 15/16" - 1" 3/4 30"-36" 2" 3/4 9" 13/16 Dimensions and clearances Cut out for venting system and conduit 1" 1/4 1" 1/4 9" 1/4 23" 5/16 10" 21" 3/4 7" 1/16 3" 3/8 13/16" 13/16" Cut out for blower unit housing pa ...

  • Zephyr EGL-E36AS - page 8

    8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting version ). Sho ...

  • Zephyr EGL-E36AS - page 9

    9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4 ” x 10” Rect., straight 6 ” Round,, straight 7", 8” Round,, straight 3 1/4 ” x 10” Rect.90° elbow 3 1/4 ” x 10” Rect.45° elbow 3 1/4 ” x 10” Rect.90° flat elbow 3 1/4 ” x 10” Rect. wall cap with damper 3 1/4 ” x 10” Rect.to 6 ” round trans ...

  • Zephyr EGL-E36AS - page 10

    10 Inst allation 1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and ...

  • Zephyr EGL-E36AS - page 11

    11 www .zephyronline.com 8. Fit the blower unit housing inside the cabinet through the bottom opening. Check that fixing springs goes over the bottom panel.. Bottom opening Bottom panel Fixing springs 9. Apply two brackets (one per side) to the blower unit housing......... Upper bracket ....... lock in place (check that each bracket , once in posit ...

  • Zephyr EGL-E36AS - page 12

    12 ..... tighten securely the two screws on upper brackets, check that blower housing is now well blocked, then, from the inside of the hood, fix definitively the lower brackets with one screw each. Adjusting screws Upper + lower bracket definitive fixing screws 10. Refinish the installation to cabinet with two fixing screws. Final fixing screw Fin ...

  • Zephyr EGL-E36AS - page 13

    13 www .zephyronline.com 12. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service panel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GR ...

  • Zephyr EGL-E36AS - page 14

    14 Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamps may vary) 5 Sliding Glass 6 Hood canopy 6 1 2 3 4 5 ...

  • Zephyr EGL-E36AS - page 15

    15 www .zephyronline.com Controls Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking. Description of control panel: A B C D E F A- ...

  • Zephyr EGL-E36AS - page 16

    16 Maintenance CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use the supplied cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks. Therefore ...

  • Zephyr EGL-E36AS - page 17

    17 www .zephyronline.com T rouble Shooting After inst allation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector ...

  • Zephyr EGL-E36AS - page 18

    18 W arranty T O OBT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty . T O OBT AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please keep a copy of your dated pro ...

  • Zephyr EGL-E36AS - page 19

    19 www .zephyronline.com List of Part and Accessories Part Description Part# halogen bulb, 12V 20 W metal filter Part Description Part# Ductless Recirculating Kit charcoal replacement filter Z0B-0013 ZRC-00GL Z0F-C063 remote control GF02ZA ...

  • Zephyr EGL-E36AS - page 20

    20 ...

  • Zephyr EGL-E36AS - page 21

    21 www .zephyronline.com ...

メーカー Zephyr カテゴリー Ventilation Hood

Zephyr EGL-E36ASのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EGL-E36ASの取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr EGL-E36ASの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr EGL-E36ASの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr EGL-E36ASの取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr EGL-E36ASのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr EGL-E36ASの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr EGL-E36ASデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr EGL-E36ASを使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr EGL-E36ASユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr EGL-E36ASの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr EGL-E36ASの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr EGL-E36ASに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr EGL-E36ASデバイスの基本機能を使うにあたってのヒント。 Zephyr EGL-E36ASのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr EGL-E36ASに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr EGL-E36ASのメーカー/サービスへの連絡先に関する情報。

Zephyr EGL-E36ASについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr EGL-E36ASの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr EGL-E36ASで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)