Manuale per l’uso Cleveland Range SEL-30-T1

23 pagine 0.8 mb
Scarica

Vai alla pagina of 23

Summary
  • Cleveland Range SEL-30-T1 - page 1

    SE95051 Operators Manual Installation, Operation & Service Electric T1 Skillets 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .cle v elandrange .com MODELS : SEL-30-T1 SEL-40-T1 Enodis ...

  • Cleveland Range SEL-30-T1 - page 2

    FOR THE USER IMPOR T ANT THE INST ALLA TION AND CONNECTION MUST COMPL Y WITH THE LOCAL AND NA TIONAL ELECTRICAL CODES . ENSURE ELECTRICAL SUPPL Y CONFORMS WITH ELECTRICAL CHARA CTERISTICS SHO WN ON THE RA TING LABEL ALL SER VICE MUST BE PERFORMED BY A QU ALIFIED CLEVELAND RANGE TECHNI- CIAN. RET AIN THIS MANUAL FOR YOUR REFERENCE. W ARNING : Improp ...

  • Cleveland Range SEL-30-T1 - page 3

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection / Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 4

    1 GENERAL Installation of the unit must be accomplished by qualified electrical installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NS ...

  • Cleveland Range SEL-30-T1 - page 5

    2 WIRE CONNECTION Note: Ensure main power is turned off befor e connecting wires. General Information Install in accordance with local codes and/or the National Electric Code ANSI/NFP A No. 70-1990 (USA) or the Canadian Electric Code CSA Standard C22.1 (Canada). A separate fused dis- connect switch must be supplied and installed. The unit must be e ...

  • Cleveland Range SEL-30-T1 - page 6

    3 DPK (OPTION) 39" 991mm 35" 889mm (RIM HEIGHT) 71" 1804mm 75 28 3/4" 731mm (P AN SURFACE) A B (P AN SURF ACE) 41" 1042mm H C 25 15/16" (659mm) 3 7/8" (99mm) C 5 1/4" (134mm) (FAUCET OPEN) 30" (762mm) 5" (127mm) (MANUAL TIL T HANDLE) D RECOMMENDED FLOOR SLOPE 1" (26mm) IN 4' (1220mm) FLOOR ...

  • Cleveland Range SEL-30-T1 - page 7

    4 OPERA TING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. Power Switch Lower position - power to the unit is OFF . Upper position - power to the unit is ON. 2. T emperature Dial Regulates the surface temperature of the pan. 3. Heat Indicator Light T ur ns ON when heating system is on and OFF when system is off. 4. Hand Tilt Whe ...

  • Cleveland Range SEL-30-T1 - page 8

    5 OPERA TING THE UNIT 1. Ensure electrical supply to the unit is in the ON position. 2. T ur n Power Switch ( 1 ) to the ON position. The yel- low Heat Indicator Light ( 3 ) will indicate power is on. 3. MANUAL TIL T ( 4 ) : Cleveland skillets are equipped with a manual tilt mechanism for raising and lowering the pan. T o raise pan, raise the cover ...

  • Cleveland Range SEL-30-T1 - page 9

    6 CARE AND CLEANING Y our skillet must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operation. W ARNING: Do not use chloride base detergents. There is a gr owing number of non-chloride cleaners available. If unsure of the cleaners chlorine content consult the supplier . Also av ...

  • Cleveland Range SEL-30-T1 - page 10

    7 F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE50825-7 3/4" SPOUT . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A95022 RET AINING RING . . . . . . . . . . . . . . . . . . . .1 3. F A05002-19 "O" RING . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. KE51736 LONG F AUCET NUT . . . . . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 11

    8 P AN MOUNT ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. HEA TING ELEMENTS . . . . . . . . . . . .6 3 3 0 0 G G A A L L L L O O N N SK50845-1 ELEMENT , 2.00 KW , 480 V AC SK50845-2 ELEMENT , 2.67 KW , 416 V AC SK50845-3 ELEMENT , 2.00 KW , 416 V AC SK50845-4 ELEMENT , 2.67 KW , 240 V AC ELEMENT , 2.00 KW , 208 V AC SK50845-5 ELEMENT , 2.00 ...

  • Cleveland Range SEL-30-T1 - page 12

    9 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE51730 TIL T SHAFT BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A31010 LOCK W ASHER, 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3. F A20030 HEX NUT , 3/8-16 . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 13

    10 17. KE50315 WORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 18. F A95005 TENSION PIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 19. KE52193 THRUST BEARING SP ACER . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 14

    11 1 2 11 9 12 15 10 14 13 3 4 5 6 7 8 8 9 9 16 SECTION A - A SECTION B - B SECTION C - C B A AB C C WARNING : Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. AVERT ...

  • Cleveland Range SEL-30-T1 - page 15

    12 COMPONENT PL A TE ASSEMB L IES ITEM P ART DESCRIPTION QTY . NO . NO . M M A A N N U U A A L L T T I I L L T T 1. SK00411 COMPONENT PLA TE WELDMENT .1 2. SK2475500 RELA Y . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK2475600 HOLDER . . . . . . . . . . . . . . . . . . . . . .1 4. SK2475700 SPRING . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 16

    13 FRAME / LID ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK00392-1 FRAME WELDMENT (30 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SK00392-3 FRAME WELDMENT (40 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2457192 LID ASSEMBL Y (30 GALLON) . . . . . . . . . . . . . . . . ...

  • Cleveland Range SEL-30-T1 - page 17

    14 1 2 3 4 5 6 7 2" T ANGENT DRA W-OFF V AL VE ITEM NO . P ART NO . DESCRIPTION QTY . 1. - 7. KE50972-B DRAW-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. F A95049 WING NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. ...

  • Cleveland Range SEL-30-T1 - page 18

    15 W ARNING : Any maintenance or service involving disassembly of components should be made by a qualified service technician. Ensure electrical and water supply (if applicable) to the unit are shut of f. ! LUBRICA TION PROCEDURE Lubricate the following parts ever y three months to insure smooth operation and r educe wear . TRUNNION HOUSING, WORM S ...

  • Cleveland Range SEL-30-T1 - page 19

    16 SEQUENCE OF OPERA TIONS When using these instructions refer to the SEL-TI wiring schematic. 1. Supply V oltage is sent to the primar y of the 120 V AC transformer . 2. Supply voltage is sent to the normally open con- tacts of the Heat Contactors, C 1 and C2. 3. 120 V AC is sent from the secondary of the 120V AC transformer through the 3 amp fuse ...

  • Cleveland Range SEL-30-T1 - page 20

    17 P ART NO . DESCRIPTION QTY . H H E E A A T T I I N N G G E E L L E E M M E E N N T T S S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 30 GALLON SK50845-1 ELEMENT , 2.00 KW , 480 V AC SK50845-2 ELEMENT , 2.67 KW , 416 V AC SK50845- ...

  • Cleveland Range SEL-30-T1 - page 21

    18 WIRING DIAGRAM RESISTOR ELECTRICAL COMPONENT PART #s FUSE 3A KE52936-6 10 FUSE 1.25A KE52936-8 10 RELAY 1 SK2475500 12 HEATING ELEMENTS - SEE "PAN MOUNT ASSEMBLY" ON PAGE # 8 ON/OFF SWITCH SK2474103 11 HIGH LIMIT KE55069-7 8 THERMOSTAT SK2142002 11 SENSOR SK50933-1 8 HEAT INDICATOR SK50905-1 16 CIRCUIT BREAKER KE50579-1 10 MERCURY SWIT ...

  • Cleveland Range SEL-30-T1 - page 22

    19 19 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET RÉENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARRÊT DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARRÊT RAPIDE D'URGENCE P ARADA R ...

  • Cleveland Range SEL-30-T1 - page 23

    20 20 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE ZÜNDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO KÜHLUNG MIXER BRIDGE PONT DU MÉLANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BRÜCKE RI ...

Fabbricante Cleveland Range Categoria Fryer

I documenti che otteniamo dal fabbricante del dispositivoCleveland Range SEL-30-T1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cleveland Range
- manuali per l’uso SEL-30-T1
- schede prodotto Cleveland Range
- opuscoli
- o etichette energetiche Cleveland Range SEL-30-T1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cleveland Range SEL-30-T1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cleveland Range SEL-30-T1, manuali di manutenzione, brevi manuali o manuali utente Cleveland Range SEL-30-T1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cleveland Range SEL-30-T1.

Manuali per l’uso simili

Manuale completo del dispositivo Cleveland Range SEL-30-T1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cleveland Range SEL-30-T1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cleveland Range SEL-30-T1.

Il manuale per l’uso completo Cleveland Range, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cleveland Range SEL-30-T1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cleveland Range SEL-30-T1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cleveland Range SEL-30-T1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cleveland Range SEL-30-T1 - che ci dovrebbe aiutare nei primi passi durante l'uso Cleveland Range SEL-30-T1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cleveland Range SEL-30-T1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cleveland Range SEL-30-T1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cleveland Range SEL-30-T1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cleveland Range SEL-30-T1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cleveland Range SEL-30-T1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine