Manuale per l’uso Vulcan-Hart EF5 ML-114944

12 pagine 0.24 mb
Scarica

Vai alla pagina of 12

Summary
  • Vulcan-Hart EF5 ML-114944 - page 1

    INST ALLA TION & OPERA TION MANU AL VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31052 (1-98) MODELS EF3, EF4, & EF5 ECONOFR Y GAS FR YERS MODELS EF3 ML-52099 EF4 ML-114943 EF5 ML-114944 Model EF3 ...

  • Vulcan-Hart EF5 ML-114944 - page 2

    — 2 — IMPOR T ANT FOR Y OUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE ...

  • Vulcan-Hart EF5 ML-114944 - page 3

    — 3 — Installation, Operation and Care of MODELS EF3, EF4 & EF5 ECONOFR Y GAS FR YERS KEEP THESE INSTR UCTIONS FOR FUTURE USE GENERAL Your Vulcan-Hart Gas Fryer is produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance. It is suggested that you thoroug ...

  • Vulcan-Hart EF5 ML-114944 - page 4

    — 4 — LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (152.4mm) from the sides and 6" (152.4mm) from the back of the fryer; minimum clearance from non-combustible construction is 0" from the sides and back of the fryer. There must be at least ...

  • Vulcan-Hart EF5 ML-114944 - page 5

    — 5 — Fig. 1 GAS CONNECTIONS All gas supply connections and any pipe joint compound must be resistant to the action of liquefied petroleum gases. The gas inlet is located at the lower left rear. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas supply line must be at least the equivalent of 1 / 2 &q ...

  • Vulcan-Hart EF5 ML-114944 - page 6

    — 6 — LEVELING THE FRYER Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to ensure that the fryer is level front-to-back and side-to-side in the final installed position. FLUE CONNECTIONS Adequate ventilation must be provided and must comply with NFPA Standard #96 (latest edition), and with local c ...

  • Vulcan-Hart EF5 ML-114944 - page 7

    — 7 — OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. Tank warranty may be voided by improper operation. Turn gas valve off when draining or filling. FILL FRY TANK WITH LIQ ...

  • Vulcan-Hart EF5 ML-114944 - page 8

    — 8 — PL-40677-1 Drain V alve Gas Control V alve Knob Thermostat Knob LIGHTING THE PILOT 1. Turn thermostat OFF. Thermostat is located behind the door (Fig. 3). MODEL EF3 Fig. 3 2. Push gas control valve knob and turn to OFF (Fig. 4). Wait 5 minutes for unburned gas to vent. 3. Push and turn gas control valve to the "I" in PILOT (Fig. ...

  • Vulcan-Hart EF5 ML-114944 - page 9

    — 9 — TURNING THE FRYER OFF 1. Turn the thermostat OFF. 2. Turn the gas control valve knob so the "I" in PILOT is opposite the INDEX. In this position, the pilot remains lit. 3. To shut off all gas to the system, including the pilot, turn the gas control valve knob to OFF. EXTENDED SHUTDOWN 1. Turn the manual gas shutoff valve OFF. 2. ...

  • Vulcan-Hart EF5 ML-114944 - page 10

    — 10 — SHORTENING LIFE Shortening life may be extended by following these guidelines: • Do not salt foods over the fryer. • Use good quality shortening. • Filter shortening at least daily. • Replace shortening if it becomes poorly flavored. • Keep equipment and surroundings clean. • Set thermostats correctly. • Remove excess moist ...

  • Vulcan-Hart EF5 ML-114944 - page 11

    — 11 — 7. With a small amount of warm shortening, flush out scraps and sediment in the fry tank. Drain the tank thoroughly and wipe clean. 8. If it is necessary to clean the tank more thoroughly follow the procedure shown in CLEANING — WEEKLY OR AS REQUIRED. 9. Close the drain valve. 10. Pour the strained shortening back into the vat. 11. Add ...

  • Vulcan-Hart EF5 ML-114944 - page 12

    — 12 — MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. VENT Annually, when fryer is cool, check the flue and clear any obstructions. SERVICE AND PARTS INFORMATION To obtai ...

Fabbricante Vulcan-Hart Categoria Fryer

I documenti che otteniamo dal fabbricante del dispositivoVulcan-Hart EF5 ML-114944 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vulcan-Hart
- manuali per l’uso EF5 ML-114944
- schede prodotto Vulcan-Hart
- opuscoli
- o etichette energetiche Vulcan-Hart EF5 ML-114944
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vulcan-Hart EF5 ML-114944.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vulcan-Hart EF5 ML-114944, manuali di manutenzione, brevi manuali o manuali utente Vulcan-Hart EF5 ML-114944. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vulcan-Hart EF5 ML-114944.

Manuali per l’uso simili

Manuale completo del dispositivo Vulcan-Hart EF5 ML-114944, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vulcan-Hart EF5 ML-114944 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vulcan-Hart EF5 ML-114944.

Il manuale per l’uso completo Vulcan-Hart, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vulcan-Hart EF5 ML-114944 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vulcan-Hart EF5 ML-114944, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vulcan-Hart EF5 ML-114944 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vulcan-Hart EF5 ML-114944 - che ci dovrebbe aiutare nei primi passi durante l'uso Vulcan-Hart EF5 ML-114944
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vulcan-Hart EF5 ML-114944
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vulcan-Hart EF5 ML-114944 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vulcan-Hart EF5 ML-114944?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vulcan-Hart EF5 ML-114944 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vulcan-Hart EF5 ML-114944 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)