  • Cleveland Range SD-450- K 6 - page 1

    SE95008 Rev . 3 Operators Manual Installation, Operation & Service Direct Steam T able T op Kettles T able-T op Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050 SD -1200 SD -1600 SD -1800 Kettles on SD Stands MODELS: SD - 450 - K 6 SD - 650 - K 12 SD - 760 ...

  • Cleveland Range SD-450- K 6 - page 2

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requir ements . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 3

    1 GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage. This unit is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NSF , ASME/Ntl.Bd., ...

  • Cleveland Range SD-450- K 6 - page 4

    2 STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Generally , kettles r equire 1/2" i.p.s. pipe, 10-45 psi steam pressur e. If the steam supply pressur e exceeds 45 psi, a pressur e reducing valve is requir ed. The st ...

  • Cleveland Range SD-450- K 6 - page 5

    OPERA TION 1. Ensur e that ther e is an adequate steam supply to the kettle. 2. T urn the steam control valve to the open position by turning the knob counter -clockwise, then allow the kettle to preheat. NOTE: When cooking egg and milk products, the kettle should NOT be preheated, as pr oducts of this nature adher e to hot cooking sur faces. These ...

  • Cleveland Range SD-450- K 6 - page 6

    4 CARE AND CLEANING Y our kettle must be cleaned r egularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. 1. Prepar e a war m water and mild detergent solution in the kettle. 2. Remove food soil inside the kettle using a nylon brush. Do not ...

  • Cleveland Range SD-450- K 6 - page 7

    5 STEAM CONTROL ASSEMBL Y SER VICE P AR TS 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 7 8 23 30 27 29 11 1 5 4 ...

  • Cleveland Range SD-450- K 6 - page 8

    6 STEAM CONTROL ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11056 Binding Head Screw , 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 T runnion, condensate return . . . . . ...

  • Cleveland Range SD-450- K 6 - page 9

    7 3 4 7 6 5 11 1 0 9 8 16 12 13 15 14 22 21 19 18 20 Se e S tea m Co ntr ol Dra wing 2 1 1 1 24 28 1 25 2 6 27 30 Se e S tea m Co ntr ol Dra wing 2 3 17 Steam In Configuration for SD Stand with Two Kettles 2 2 CONDENSATE CONDENSATE RETURN RETURN STEAM STEAM IN IN STEAM IN CONDENSATE RETURN Se e S tea m Co ntr ol Dra wing STEAM STEAM IN IN STEAM IN ...

  • Cleveland Range SD-450- K 6 - page 10

    8 PLUMBING ASSEMBL Y (for SD Stands) ITEM NO . P ART NO . DESCRIPTION QTY . 1. FI00169 T ee, 1/2" NPT . (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .3 2. KE51723 Pressur e Relief V alve, 1/2" NPT (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 11

    9 6 7 8 4 5 1 4 2 3 1 2 3 1 1 1 2 9 1 1 1 2 1 0 F AUCET ASSEMBLIES ...

  • Cleveland Range SD-450- K 6 - page 12

    10 F AUCET ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 13

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve (optional on kettles) must be checked at least twice a year as part of the normal maintenance per formed. 1. Open steam valve and preheat kettle. 2. Stand to the side of the pressur e relief valve discharge tube and pull ring three or four times to insure fr ee movement. Hold valv ...

  • Cleveland Range SD-450- K 6 - page 14

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Pr obable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and power ed by a generator the units should ...

  • Cleveland Range SD-450- K 6 - page 15

    9.88" 251mm 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN 8.00" 203mm 9.38" 238mm 12.25" 311mm 12.50" 318mm 8.13" 207mm 9.31" 236mm 1.56" 40mm 3.50" 89mm 13 SPECIFICA TION DRA WINGS KDT -1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 4" Left - 0 Back - 0 ...

  • Cleveland Range SD-450- K 6 - page 16

    14 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D H 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN STEAM CONTROL VALVE K M L N J 1.00" 25mm 1.25"/32mm WALL 2.25" 57mm GAL. LITRE A B C D E F G H J K L M N 3 11 IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 mm 356 254 384 317 210 ...

  • Cleveland Range SD-450- K 6 - page 17

    15 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN K M J 1.75" 45mm WALL H STEAM CONTROL VALVE 1.25" 32mm 2.25" 57mm L MARINE LOCK GAL. LITRE A B C D E F G H J K L M 3 11 IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 mm 521 425 584 565 3 ...

  • Cleveland Range SD-450- K 6 - page 18

    SD ST ANDS WITH KETTLES CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 0 Left - 0 Back - 0 MARINE LOCK SLIDING DRAIN PAN 18.00" 457mm 6.00" 152mm A 27.75" 706mm 22.00" 610mm 1.47" 37mm 1.47" 37mm H C 16.88" 429mm 13.75" 349mm 33.50" 851mm D 5.00" 127mm 3.25" 83mm B ...

Fabbricante Cleveland Range Categoria Hot Beverage Maker

I documenti che otteniamo dal fabbricante del dispositivoCleveland Range SD-450- K 6 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cleveland Range
- manuali per l’uso SD-450- K 6
- schede prodotto Cleveland Range
- opuscoli
- o etichette energetiche Cleveland Range SD-450- K 6
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cleveland Range SD-450- K 6.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cleveland Range SD-450- K 6, manuali di manutenzione, brevi manuali o manuali utente Cleveland Range SD-450- K 6. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cleveland Range SD-450- K 6.

Manuale completo del dispositivo Cleveland Range SD-450- K 6, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cleveland Range SD-450- K 6 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cleveland Range SD-450- K 6.

Il manuale per l’uso completo Cleveland Range, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cleveland Range SD-450- K 6 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cleveland Range SD-450- K 6, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cleveland Range SD-450- K 6 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cleveland Range SD-450- K 6 - che ci dovrebbe aiutare nei primi passi durante l'uso Cleveland Range SD-450- K 6
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cleveland Range SD-450- K 6
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cleveland Range SD-450- K 6 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cleveland Range SD-450- K 6?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cleveland Range SD-450- K 6 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cleveland Range SD-450- K 6 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)