  • Cleveland Range SD-450- K 6 - page 1

    SE95008 Rev . 3 Operators Manual Installation, Operation & Service Direct Steam T able T op Kettles T able-T op Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050 SD -1200 SD -1600 SD -1800 Kettles on SD Stands MODELS: SD - 450 - K 6 SD - 650 - K 12 SD - 760 ...

  • Cleveland Range SD-450- K 6 - page 2

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requir ements . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 3

    1 GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage. This unit is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NSF , ASME/Ntl.Bd., ...

  • Cleveland Range SD-450- K 6 - page 4

    2 STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Generally , kettles r equire 1/2" i.p.s. pipe, 10-45 psi steam pressur e. If the steam supply pressur e exceeds 45 psi, a pressur e reducing valve is requir ed. The st ...

  • Cleveland Range SD-450- K 6 - page 5

    OPERA TION 1. Ensur e that ther e is an adequate steam supply to the kettle. 2. T urn the steam control valve to the open position by turning the knob counter -clockwise, then allow the kettle to preheat. NOTE: When cooking egg and milk products, the kettle should NOT be preheated, as pr oducts of this nature adher e to hot cooking sur faces. These ...

  • Cleveland Range SD-450- K 6 - page 6

    4 CARE AND CLEANING Y our kettle must be cleaned r egularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. 1. Prepar e a war m water and mild detergent solution in the kettle. 2. Remove food soil inside the kettle using a nylon brush. Do not ...

  • Cleveland Range SD-450- K 6 - page 7

    5 STEAM CONTROL ASSEMBL Y SER VICE P AR TS 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 7 8 23 30 27 29 11 1 5 4 ...

  • Cleveland Range SD-450- K 6 - page 8

    6 STEAM CONTROL ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11056 Binding Head Screw , 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 T runnion, condensate return . . . . . ...

  • Cleveland Range SD-450- K 6 - page 9

    7 3 4 7 6 5 11 1 0 9 8 16 12 13 15 14 22 21 19 18 20 Se e S tea m Co ntr ol Dra wing 2 1 1 1 24 28 1 25 2 6 27 30 Se e S tea m Co ntr ol Dra wing 2 3 17 Steam In Configuration for SD Stand with Two Kettles 2 2 CONDENSATE CONDENSATE RETURN RETURN STEAM STEAM IN IN STEAM IN CONDENSATE RETURN Se e S tea m Co ntr ol Dra wing STEAM STEAM IN IN STEAM IN ...

  • Cleveland Range SD-450- K 6 - page 10

    8 PLUMBING ASSEMBL Y (for SD Stands) ITEM NO . P ART NO . DESCRIPTION QTY . 1. FI00169 T ee, 1/2" NPT . (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .3 2. KE51723 Pressur e Relief V alve, 1/2" NPT (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 11

    9 6 7 8 4 5 1 4 2 3 1 2 3 1 1 1 2 9 1 1 1 2 1 0 F AUCET ASSEMBLIES ...

  • Cleveland Range SD-450- K 6 - page 12

    10 F AUCET ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SD-450- K 6 - page 13

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve (optional on kettles) must be checked at least twice a year as part of the normal maintenance per formed. 1. Open steam valve and preheat kettle. 2. Stand to the side of the pressur e relief valve discharge tube and pull ring three or four times to insure fr ee movement. Hold valv ...

  • Cleveland Range SD-450- K 6 - page 14

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Pr obable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and power ed by a generator the units should ...

  • Cleveland Range SD-450- K 6 - page 15

    9.88" 251mm 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN 8.00" 203mm 9.38" 238mm 12.25" 311mm 12.50" 318mm 8.13" 207mm 9.31" 236mm 1.56" 40mm 3.50" 89mm 13 SPECIFICA TION DRA WINGS KDT -1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 4" Left - 0 Back - 0 ...

  • Cleveland Range SD-450- K 6 - page 16

    14 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D H 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN STEAM CONTROL VALVE K M L N J 1.00" 25mm 1.25"/32mm WALL 2.25" 57mm GAL. LITRE A B C D E F G H J K L M N 3 11 IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 mm 356 254 384 317 210 ...

  • Cleveland Range SD-450- K 6 - page 17

    15 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN K M J 1.75" 45mm WALL H STEAM CONTROL VALVE 1.25" 32mm 2.25" 57mm L MARINE LOCK GAL. LITRE A B C D E F G H J K L M 3 11 IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 mm 521 425 584 565 3 ...

  • Cleveland Range SD-450- K 6 - page 18

    SD ST ANDS WITH KETTLES CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 0 Left - 0 Back - 0 MARINE LOCK SLIDING DRAIN PAN 18.00" 457mm 6.00" 152mm A 27.75" 706mm 22.00" 610mm 1.47" 37mm 1.47" 37mm H C 16.88" 429mm 13.75" 349mm 33.50" 851mm D 5.00" 127mm 3.25" 83mm B ...

Manufacturer Cleveland Range Category Hot Beverage Maker

Documents that we receive from a manufacturer of a Cleveland Range SD-450- K 6 can be divided into several groups. They are, among others:
- Cleveland Range technical drawings
- SD-450- K 6 manuals
- Cleveland Range product data sheets
- information booklets
- or energy labels Cleveland Range SD-450- K 6
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cleveland Range SD-450- K 6.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cleveland Range SD-450- K 6, service manual, brief instructions and user manuals Cleveland Range SD-450- K 6. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cleveland Range SD-450- K 6.

A complete manual for the device Cleveland Range SD-450- K 6, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cleveland Range SD-450- K 6 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cleveland Range SD-450- K 6.

A complete Cleveland Range manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cleveland Range SD-450- K 6 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cleveland Range SD-450- K 6, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cleveland Range SD-450- K 6, that we can find in the current document
3. Tips how to use the basic functions of the device Cleveland Range SD-450- K 6 - which should help us in our first steps of using Cleveland Range SD-450- K 6
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cleveland Range SD-450- K 6
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cleveland Range SD-450- K 6 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cleveland Range SD-450- K 6?

Use the form below

If you did not solve your problem by using a manual Cleveland Range SD-450- K 6, ask a question using the form below. If a user had a similar problem with Cleveland Range SD-450- K 6 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)