    DEMOLITION HAMMER Model 93853 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2006 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artwork contained ...

  • Chicago Electric 93853 - page 2

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 2 SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz / 1500 W 20 A (Start Up) / 9.5 A (No Load) / 13.0 A (With Load) Power Cord T ype: 82” Long / 14 A WG x 2C Power Cord Plug T ype: 2-Prong / Polarized Power Switch T ype: 2-Position T oggle Switch w/Slider Cover Blows Per Min ...

  • Chicago Electric 93853 - page 3

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 3 ELECTRICAL SAFETY Grounded tools must be plugged into an outlet properly installed and 1. grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way . Do not use any adapter plugs. Check with a qualied electrician if yo ...

  • Chicago Electric 93853 - page 4

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 4 Remove adjusting keys or wrenches before turning the power tool on. 4. A wrench or a key that is left attached to a rotating part of the power tool may result in personal injury . Do not overreach. Keep proper footing and balance at all times. 5. Proper footing and balance enable ...

  • Chicago Electric 93853 - page 5

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 5 SER VICE T ool service must be performed only by qualied repair personnel. 1. Service or maintenance performed by unqualied personnel could result in a risk of injury . When servicing a tool, use only identical replacement parts. Follow 2. instructions in the “Inspection, ...

  • Chicago Electric 93853 - page 6

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 6 Do not drill or break into existing walls, oors, or other blind areas where 1 1. electrical wiring may exist. If this situation is unavoidable, disconnect all fuses or circuit breakers feeding the worksite. Use a metal detector to determine if there are gas or water pipes hidd ...

  • Chicago Electric 93853 - page 7

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 7 these chemicals are: lead from lead-based paints, crystalline silica from bricks and cement or other masonry products, arsenic and chromium from chemically treated lumber . Y our risk from these exposures varies, depending on how often you do this type of work. T o reduce your ex ...

  • Chicago Electric 93853 - page 8

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 8 VIBRA TION HAZARD This tool vibrates during use. Repeated or long-term exposure to vibration may cause temporary or permanent physical injury , particularly to the hands, arms and shoulders. T o reduce the risk of vibration-related injury: Anyone using vibrating tools regularly o ...

  • Chicago Electric 93853 - page 9

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 9 GROUNDING Improperly connecting the grounding wire can result in electric shock. Check with a qualied electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from ...

  • Chicago Electric 93853 - page 10

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 10 with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Outlets for 2-Prong Plug.) Double insulated tools may be used in either of the 120 volt outlets shown in the 2. preceding illustration. (Se ...

  • Chicago Electric 93853 - page 11

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 1 1 RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 ? ...

  • Chicago Electric 93853 - page 12

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 12 UNP ACKING When unpacking, check to make sure all the parts shown on the Parts List on page 16 are included. If any parts are missing or broken, please call Harbor Freight T ools at the number shown on the cover of this manual as soon as possible. PRODUCT FEA TURES Note: For add ...

  • Chicago Electric 93853 - page 13

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 13 V ariable Speed Control (72): 3. The Demolition Hammer is equipped with a V ariable Speed Control Dial. The impact rate (BPM) and rotating speed (RPM) can be varied according to the type of work being performed by setting the V ariable Speed Control Dial to the selected setting: ...

  • Chicago Electric 93853 - page 14

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 14 Grasp the Demolition Hammer rmly by its rear Handle (62) and Auxiliary Handle 3. (104A). Then, turn the Power Switch (66) to its “ON” position to begin work. IMPORT ANT : 4. This Demolition Hammer requires a short period of time to warm up. Depending on the room temperatu ...

  • Chicago Electric 93853 - page 15

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 15 are worn down, replace both Carbon Brushes. If, however , the Carbon Brushes are just dirty they may be cleaned by rubbing them with a pencil eraser . If cleaning and replacing used brushes, try to install them in the same holders and in the same direction they were removed. Whe ...

  • Chicago Electric 93853 - page 16

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 16 TROUBLESHOOTING Problem Possible Solution Chisel installs with difculty . Make sure the Chisel shank, Front Cap, and Slider are free of debris and lightly oiled or greased. (See page 12.) T ool does not run. Make sure the Power Switch is in its “ON” position. (See page 1 ...

  • Chicago Electric 93853 - page 17

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 17 P ARTS LIST REV 06f, 08g, 10d * Cannot be ordered individually . Must be ordered as a complete Motor Assembly . Includes parts 33, 34, 35, 36, 37, 40, 58, 59, 60, 61, 73, 74. ** Cannot be ordered individually . Must be ordered as a complete Carbon Brush Assembly . Includes parts ...

  • Chicago Electric 93853 - page 18

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 18 ASSEMBL Y DIAGRAM REV 08g, 10d Note: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts. 106: Spade Chisel not shown. 107: Ball Point Chisel not shown. ...

  • Chicago Electric 93853 - page 19

    SKU 93853 For technical questions, please call 1-800-444-3353 P AGE 19 LIMITED 1 YEAR / 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor , the belts ...

Fabbricante Chicago Electric Categoria Power Hammer

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 93853 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 93853
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 93853
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 93853.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 93853, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 93853. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 93853.

Manuale completo del dispositivo Chicago Electric 93853, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 93853 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 93853.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 93853 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 93853, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 93853 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 93853 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 93853
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 93853
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 93853 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 93853?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 93853 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 93853 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)