DeLonghi DEFSGG 24 SSの取扱説明書

20ページ 0.89 mb
ダウンロード

ページに移動 of 20

Summary
  • DeLonghi DEFSGG 24 SS - page 1

    IMPORT ANT - PLEASE READ AND FOLLOW ✓ Before beginning, please r ead these instructions completely and carefully . ✓ Do not remove permanently af fixed labels, warnings, or plates from the product. This may void the warranty . ✓ Please observe all local and national codes and ordinances. ✓ Please ensure that this pr oduct is properly gr oun ...

  • DeLonghi DEFSGG 24 SS - page 2

    2 ✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • lmmediately call your gas supplier from a neighbor's phone. Follow t ...

  • DeLonghi DEFSGG 24 SS - page 3

    3 DA T A PLA TE CONVERSION LABEL This appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any none domestic application and therefor e should not be used in a commercial envir onmement. The appliance guarantee will be void if the appliance is used within a none domestic environnement i. ...

  • DeLonghi DEFSGG 24 SS - page 4

    4 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier . IMPORT ANT : The use of suitable protective clothing/gloves is r ecommended when handling, insta ...

  • DeLonghi DEFSGG 24 SS - page 5

    5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition. 2. Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Sta ...

  • DeLonghi DEFSGG 24 SS - page 6

    6 (303 m m ) (303 m m ) 11" 15/16 11" 15/16 (150 mm) 5" 57/64 installation  PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. Range dimensions: • width: 23” 7/8 (606.5 mm) • depth: 24” 5/64 (611.6 mm) • height (without backguard): MIN 35” 7/16 ...

  • DeLonghi DEFSGG 24 SS - page 7

    7  A B A (914 mm) 36" 30" min. (762 mm) (457 mm) 18" min. 0" 0" (0 m m ) (0 m m ) 20" min. (500 mm) 1 1 " 13/16 m in . (3 0 0 m m ) 13" max. (330 mm) 0" (0 m m ) 3" min. (76 mm) 13" max. (330 mm ) (914 mm) 36" 0" (0 m m ) 2 0 " m in . (5 0 0 m m ) 30" min. (762 mm) (457 m ...

  • DeLonghi DEFSGG 24 SS - page 8

    8  LEVELLING THE RANGE The range is equipped with 4 LEVELLING FEET and may be levelled by scr ewing or unscrewing the feet with a spanner (fig. 1.8). It is important to observe the directions of figures 1.6, 1.7a, 1.7b . + 8 mm + 5/16" + 8 mm + 5/16" 0 mm 0" + 20 mm + 25/32" Fig. 1.6 Fig. 1.7a Fig. 1.7b Fig. 1.8 A ...

  • DeLonghi DEFSGG 24 SS - page 9

    9 gas connection  Gas supply line Shutoff valve “open” position To range Explosion Hazard Use a new CSA or UL approved gas supply line. Install a shut-off valve. Securely tighten all gas connec- tions. If connected to LP , have a quali- fied person make sure gas pr es- sure does not exceed 14" water column. Examples of a qualified perso ...

  • DeLonghi DEFSGG 24 SS - page 10

    10  PRESSURE REGULA TOR INST ALLA TION LOCK Arrow STEP 1 Mount the 1/2” NPT (conical) male connector to the pressur e r egulator and tighten by using a wr ench. Do not over tighten the connector . Over tightening may crack regulator . STEP 2 Assemble the 1/2” NPT connector + pressur e regulator group to the extension pipe interposing the gas ...

  • DeLonghi DEFSGG 24 SS - page 11

    11  To mains connection Manifold test point pressure 1/8” NPT To range Range manifold Manifold male pipe fitting Connector Pressure regulator 1/2” G cylindrical (ISO 228-1) male 1/2” G cylindrical (ISO 228-1) female 1/2” NPT (conical) male 1/2” NPT female 1/2” NPT female WARNING: check the right positioning of the gas regulator. The ...

  • DeLonghi DEFSGG 24 SS - page 12

    12  To mains connection To range Manifold test point pressure 1/8” NPT Screw Unscrew Fig. 2.5 5. Leak T esting: IMPORT ANT : Leak testing of the appliance shall be conducted as follows: • After final gas connection is made, turn on manual gas valve and test all connections in gas supply piping and appliance for gas leaks with a soapy water s ...

  • DeLonghi DEFSGG 24 SS - page 13

    13  1 2 3 4 Fig. 2.6b Fig. 2.6a REGULA TOR COVER Pressur e r egulator CONVERSION TO LP/PROP ANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced accor ding to the “INJECTORS T ABLE”. The nozzle diameters, expressed in hundr edths of a millimetre, ar e marked on the body of ...

  • DeLonghi DEFSGG 24 SS - page 14

    14  SETTING THE BURNER MINIMUM When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. To r egulate the flame follow the instructions below: – Light the burner – Set the gas valve to position – Remove the knob – Wit ...

  • DeLonghi DEFSGG 24 SS - page 15

    15  OPERA TIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERS a) Oven Burner – Lift and remove the lower panel inside the oven. – Remove the burner securing screw (fig. 2.10). – Withdraw the burner as shown in figure 2.11 and rest it inside the oven. T ake care not to damage the wire to the ignition elec ...

  • DeLonghi DEFSGG 24 SS - page 16

    16  After regulation r epeat the operations indicated in paragraph “2. Pressure r egulator” at page 9. If the range has been disconnected and then connected again to the gas supply line r epeat the operations indicated in paragraph “5. Leak T esting” at page 12. IMPORT ANT : After conversion to LP/PROP ANE gas has been carried out affix ...

  • DeLonghi DEFSGG 24 SS - page 17

    17 electrical connection  If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the range is proper- ly grounded. Do Not ground to a gas pipe. A 120-volt, 60-Hz, AC-only , 15-ampere, fused elec ...

  • DeLonghi DEFSGG 24 SS - page 18

    18  WIRING DIAGRAM Fig. 3.2 P1 F1 MS AS CF N/7 L/8 S1 PA TL3 V T LF EC A M N L ELECTRIC DIAGRAM KEY F1 Switch MS Security microswitch S1 Cooling fan safety lamp LF Oven lamp AS Air switch V Fan TL3 Thermal overload PA Ignition switches group A Ignition coil EC Electronic clock CF Cooling fan M Te r m inal block T Earth connection ...

  • DeLonghi DEFSGG 24 SS - page 19

    19 ...

  • DeLonghi DEFSGG 24 SS - page 20

    Cod. 1102749 - ß3 The manufacturer cannot be held responsible for possible inaccuracies due to printing or transcription err ors in the present booklet. The manufacturer reserves the right to make all modifications to its pr oducts deemed necessary for manufacture or commercial reasons at any moment and without prior notice, without jeopar dising ...

メーカー DeLonghi カテゴリー Range

DeLonghi DEFSGG 24 SSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DEFSGG 24 SSの取扱説明書
- DeLonghiの製品カード
- パンフレット
- またはDeLonghi DEFSGG 24 SSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、DeLonghi DEFSGG 24 SSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、DeLonghi DEFSGG 24 SSの取り付け説明書、サービスマニュアル、簡易説明書、またはDeLonghi DEFSGG 24 SSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、DeLonghi DEFSGG 24 SSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

DeLonghi DEFSGG 24 SSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDeLonghi DEFSGG 24 SSを使用するのを助ける技術的文書のことです。説明書は通常、全てのDeLonghi DEFSGG 24 SSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

DeLonghiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. DeLonghi DEFSGG 24 SSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDeLonghi DEFSGG 24 SSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。DeLonghi DEFSGG 24 SSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. DeLonghi DEFSGG 24 SSデバイスの基本機能を使うにあたってのヒント。 DeLonghi DEFSGG 24 SSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。DeLonghi DEFSGG 24 SSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDeLonghi DEFSGG 24 SSのメーカー/サービスへの連絡先に関する情報。

DeLonghi DEFSGG 24 SSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDeLonghi DEFSGG 24 SSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDeLonghi DEFSGG 24 SSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)