SPX Cooling Technologies 600の取扱説明書

12ページ 2.16 mb
ダウンロード

ページに移動 of 12

Summary
  • SPX Cooling Technologies 600 - page 1

    / Mar le y Class 60 0 Cooling T ower / ...

  • SPX Cooling Technologies 600 - page 2

    2 ...

  • SPX Cooling Technologies 600 - page 3

    3 / Flexibility of Design / Class 600 cooling towers are a dir ect descendent of the Doubleflow ® crossflow tower that was designed and patented by Marley in 1938. In 1957, Marley’ s development of hanging fill, wide indented louvers, and stable FRP velocity-recovery fan cylinders enabled the evolution of that Doubleflow tower into the class ...

  • SPX Cooling Technologies 600 - page 4

    4 Fans Marley designed and manufactured fans ar e used on all Marley crossflow towers. The fan selection and fan speed for a given tower are based on tower cell size, system losses, and horsepower requir ements. Depending on fan size, blade material is FRP (fiber reinfor ced polyester), GRE (glass reinfor ced epoxy), or cast aluminum alloy . Abov ...

  • SPX Cooling Technologies 600 - page 5

    5 Geareducer The Marley Geareducer ® has become the standar d by which all other cooling tower fan speed reducers are judged. Numer ous reduction ratios ar e available so that horsepower is applied at optimum fan speed. The specific Geareducer selection is based on fan speed and horsepower requir ements up to 300 hp per fan. Marley Geareducers ar ...

  • SPX Cooling Technologies 600 - page 6

    6 Class 600 splash fill bars are available in the following materials: • PVCin“Omega”,“Mega”or“Alpha” configurations. • Injection-moldedpolypropylene“Ladder”  configurations. • Roughsawn,preservative-tr eatedwood “G” configurations. Each cooling tower application is ...

  • SPX Cooling Technologies 600 - page 7

    7 Piping Although side inlet piping is provided as standar d, Class 600 towers are adaptable to end inlet piping. This is an economical method requiring only one riser for each series of hot water basins, regar dless of the number of fan cells. Cast iron, steel, and r einforced plastic pipe ar e all available. / W at er Distr ibution Syst em / Valv ...

  • SPX Cooling Technologies 600 - page 8

    8 / Dr ift Eliminat ors / Marley towers utilize Marley XCEL ® plus drift eliminators, a cellular , labyrinthine design which improves drift elimination by several orders of magnitude over that achievable by blade-type eliminators. Significantly lower pressur e losses also reduce fan horsepower requir ements. XCEL eliminators are thermoformed PVC ...

  • SPX Cooling Technologies 600 - page 9

    9 The diagonals brace the structure and carry loads to heavy-duty , hot dip glavanized anchor castings. The anchor castings transmit wind and/or earthquake loads from the structur e directly into the foundation. For standard wind load conditions, anchor bolts ar e requir ed only at the perimeter . Structural ceramic rings or glass reinfor ced nylon ...

  • SPX Cooling Technologies 600 - page 10

    10 / Casing / The endwalls of Class 600 towers are cased fr om the fan deck level to below the top of the basin curb with 8 oz/sq ft corrugated FRP sheets. FRP is waterproof and corrosion pr oof, is immune to biological deterioration, and requir es no maintenance. Sheets are installed on maximum 4 ′ -0 ″ spans with corrugations running horizont ...

  • SPX Cooling Technologies 600 - page 11

    11 Endwall Derrick The endwall derrick is a permanently installed tripod device of galvanized structural steel. In service, removable structural aluminum tracks are positioned acr oss the platform opening. Equipment to be handled is placed on a 4-wheel dolly—part of the equipment handling package—rolled onto the track and elevated slightly . Th ...

  • SPX Cooling Technologies 600 - page 12

    SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project. Her e is a partial listing of the additional services offer ed by SPX Cooling T echnologies to help you do your job most effect ...

メーカー SPX Cooling Technologies カテゴリー Humidifier

SPX Cooling Technologies 600のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 600の取扱説明書
- SPX Cooling Technologiesの製品カード
- パンフレット
- またはSPX Cooling Technologies 600の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SPX Cooling Technologies 600の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SPX Cooling Technologies 600の取り付け説明書、サービスマニュアル、簡易説明書、またはSPX Cooling Technologies 600のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SPX Cooling Technologies 600の製品を使用するにあたって最も人気のある説明書を閲覧できます。

SPX Cooling Technologies 600デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSPX Cooling Technologies 600を使用するのを助ける技術的文書のことです。説明書は通常、全てのSPX Cooling Technologies 600ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SPX Cooling Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SPX Cooling Technologies 600の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSPX Cooling Technologies 600の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SPX Cooling Technologies 600に関してこのドキュメントで見つけることができる全てのヒントの目次
3. SPX Cooling Technologies 600デバイスの基本機能を使うにあたってのヒント。 SPX Cooling Technologies 600のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SPX Cooling Technologies 600に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSPX Cooling Technologies 600のメーカー/サービスへの連絡先に関する情報。

SPX Cooling Technologies 600についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSPX Cooling Technologies 600の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSPX Cooling Technologies 600で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)