    / Mar le y Class 60 0 Cooling T ower / ...

  • SPX Cooling Technologies 600 - page 2

    2 ...

  • SPX Cooling Technologies 600 - page 3

    3 / Flexibility of Design / Class 600 cooling towers are a dir ect descendent of the Doubleflow ® crossflow tower that was designed and patented by Marley in 1938. In 1957, Marley’ s development of hanging fill, wide indented louvers, and stable FRP velocity-recovery fan cylinders enabled the evolution of that Doubleflow tower into the class ...

  • SPX Cooling Technologies 600 - page 4

    4 Fans Marley designed and manufactured fans ar e used on all Marley crossflow towers. The fan selection and fan speed for a given tower are based on tower cell size, system losses, and horsepower requir ements. Depending on fan size, blade material is FRP (fiber reinfor ced polyester), GRE (glass reinfor ced epoxy), or cast aluminum alloy . Abov ...

  • SPX Cooling Technologies 600 - page 5

    5 Geareducer The Marley Geareducer ® has become the standar d by which all other cooling tower fan speed reducers are judged. Numer ous reduction ratios ar e available so that horsepower is applied at optimum fan speed. The specific Geareducer selection is based on fan speed and horsepower requir ements up to 300 hp per fan. Marley Geareducers ar ...

  • SPX Cooling Technologies 600 - page 6

    6 Class 600 splash fill bars are available in the following materials: • PVCin“Omega”,“Mega”or“Alpha” configurations. • Injection-moldedpolypropylene“Ladder”  configurations. • Roughsawn,preservative-tr eatedwood “G” configurations. Each cooling tower application is ...

  • SPX Cooling Technologies 600 - page 7

    7 Piping Although side inlet piping is provided as standar d, Class 600 towers are adaptable to end inlet piping. This is an economical method requiring only one riser for each series of hot water basins, regar dless of the number of fan cells. Cast iron, steel, and r einforced plastic pipe ar e all available. / W at er Distr ibution Syst em / Valv ...

  • SPX Cooling Technologies 600 - page 8

    8 / Dr ift Eliminat ors / Marley towers utilize Marley XCEL ® plus drift eliminators, a cellular , labyrinthine design which improves drift elimination by several orders of magnitude over that achievable by blade-type eliminators. Significantly lower pressur e losses also reduce fan horsepower requir ements. XCEL eliminators are thermoformed PVC ...

  • SPX Cooling Technologies 600 - page 9

    9 The diagonals brace the structure and carry loads to heavy-duty , hot dip glavanized anchor castings. The anchor castings transmit wind and/or earthquake loads from the structur e directly into the foundation. For standard wind load conditions, anchor bolts ar e requir ed only at the perimeter . Structural ceramic rings or glass reinfor ced nylon ...

  • SPX Cooling Technologies 600 - page 10

    10 / Casing / The endwalls of Class 600 towers are cased fr om the fan deck level to below the top of the basin curb with 8 oz/sq ft corrugated FRP sheets. FRP is waterproof and corrosion pr oof, is immune to biological deterioration, and requir es no maintenance. Sheets are installed on maximum 4 ′ -0 ″ spans with corrugations running horizont ...

  • SPX Cooling Technologies 600 - page 11

    11 Endwall Derrick The endwall derrick is a permanently installed tripod device of galvanized structural steel. In service, removable structural aluminum tracks are positioned acr oss the platform opening. Equipment to be handled is placed on a 4-wheel dolly—part of the equipment handling package—rolled onto the track and elevated slightly . Th ...

  • SPX Cooling Technologies 600 - page 12

    SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project. Her e is a partial listing of the additional services offer ed by SPX Cooling T echnologies to help you do your job most effect ...

Производитель SPX Cooling Technologies Категория Humidifier

Документы, которые мы получаем от производителя устройства SPX Cooling Technologies 600 мы можем разделить на несколько групп. Это в частности:
- технические чертежи SPX Cooling Technologies
- инструкции обслуживания 600
- паспорта изделия SPX Cooling Technologies
- информационные брошюры
- энергетические этикетки SPX Cooling Technologies 600
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания SPX Cooling Technologies 600.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа SPX Cooling Technologies 600, инструкции обслуживания, короткие инструкции или инструкции пользователя SPX Cooling Technologies 600. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия SPX Cooling Technologies 600.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства SPX Cooling Technologies 600, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании SPX Cooling Technologies 600 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей SPX Cooling Technologies 600.

Полная инструкция обслуживания SPX Cooling Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией SPX Cooling Technologies 600 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания SPX Cooling Technologies 600, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся SPX Cooling Technologies 600, которое найдем в данном документе
3. Советы по использованию основных функций устройства SPX Cooling Technologies 600 - которые должны облегчить нам первые шаги во время использования SPX Cooling Technologies 600
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем SPX Cooling Technologies 600
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра SPX Cooling Technologies 600 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся SPX Cooling Technologies 600?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с SPX Cooling Technologies 600, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с SPX Cooling Technologies 600 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)