FMI (V)S36の取扱説明書

20ページ 1.6 mb
ダウンロード

ページに移動 of 20

Summary
  • FMI (V)S36 - page 1

    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved fo ...

  • FMI (V)S36 - page 2

    www .fmiproducts.com 1 1 1026-01J 2 SAFETY W ARNING: Do not install a re pla ce in ser t in th is box unle ss the manufacturer's instructions with the insert specically state this repl ace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammabl e vapors or liquids in the vicini ...

  • FMI (V)S36 - page 3

    www .fmiproducts.com 1 1 1026-01J 3 SPECIFICA TIONS 0" TO BOTTOM (LEF T SIDE ONLY) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 52" X 16" TO PERPENDICULAR 8" EACH SIDE NO T LESS THAN 12" 1" AIRS P A CE TO COMBUSTIBLE COMBUSTIBLE WA LL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIAL ...

  • FMI (V)S36 - page 4

    www .fmiproducts.com 1 1 1026-01J 4 FIREPLACE INST ALLA TION FRAMING 1. Fr am e op en ing for fir ep la ce u sin g th e dimensions shown in Figures 1 and 2. 2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring, the replace must be in stalled upon a metal or woo ...

  • FMI (V)S36 - page 5

    www .fmiproducts.com 1 1 1026-01J 5 DRAIN P AN (DP36) For outdoor installations, the replace enclo - sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the replace within the replace enclosure (see Accessories on page ...

  • FMI (V)S36 - page 6

    www .fmiproducts.com 1 1 1026-01J 6 Figure 6 - Lineal Gain Hemmed End 8" Stainless Inner Pipe 12 3 / 8 " Galvanized Outer Pipe A SSEMBL Y AND INST ALLA TION OF DOUBLE W ALL CHIMNEY SYSTEM Each double wall chimney section consists of a gal vaniz ed outer pipe, a stainl ess steel inne r ue pipe and a wire spacer . The pipe sections must ...

  • FMI (V)S36 - page 7

    www .fmiproducts.com 1 1 1026-01J 7 VENTING INST ALLA TION Continued When connecting chimney directly to the replace, the inner ue pipe section must be installed rst with the l anced side up. The outer pipe sectio n can then be installed over the ue pipe section with the hemmed end up. Press down on each pipe section until the lances se ...

  • FMI (V)S36 - page 8

    www .fmiproducts.com 1 1 1026-01J 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (3600FS-8DM-1) Fire stop spacers are requi red at each poin t wh er e th e chi mne y pe net rat es a oo r spa ce. Their purpose is to establish and maintain th e req uir ed clea ranc e be tw een the ch im ney and the combusti ...

  • FMI (V)S36 - page 9

    www .fmiproducts.com 1 1 1026-01J 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45. ...

  • FMI (V)S36 - page 10

    www .fmiproducts.com 1 1 1026-01J 10 T erminations with 16" slip pipe sections are available. The R TT -8DM and RTTL-8DM are approved for flashing installations. When nee ded, these adj ust able ter mina tio ns may be used in combinat ion with the pipe asse mbly to achieve the correct chimney height. Note : In the rare instance there is a prob ...

  • FMI (V)S36 - page 11

    www .fmiproducts.com 1 1 1026-01J 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel (see Figure 20, page 12). Note : Secure incoming gas line to wood framing to provide rigidity for threaded end . ...

  • FMI (V)S36 - page 12

    www .fmiproducts.com 1 1 1026-01J 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is c om pl et ed . Af te r e ns ur in g that the gas valve is on, apply soap and water solution to all conn ectio ns and joint s. Bubbl es forming show a leak. Correct all leaks at o ...

  • FMI (V)S36 - page 13

    www .fmiproducts.com 1 1 1026-01J 13 The following tips should be followed to as - sure that both the replac e and the glass door retain their beauty and function properly . Both the ue damper and the glass doors must be fully opened before starting the re. This will prov ide sufcie nt combust ion air and maint ain safe temperatures in ...

  • FMI (V)S36 - page 14

    www .fmiproducts.com 1 1 1026-01J 14 P ARTS WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, VS36R AND VS36RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 1 1 14 3 13 22 10 6 31 7 37/38 36 28 29 24 23 15 ...

  • FMI (V)S36 - page 15

    www .fmiproducts.com 1 1 1026-01J 15 KEY NO. P ART NO. DESCRIPTION QTY . 1 106638-01 Insulation Pan 1 2 ** Fireplace T op 1 3 106641-01 Fireplace Surround 1 4 106642-01 Air Rod Retainer 1 5 106643-01 Damper Rod Retainer 1 6 ** Firebox Bottom 1 7 ** Firebox Surround 1 8 ** Air Separator 1 9 See Below Left Refractory 1 10 See Below Right Refractory 1 ...

  • FMI (V)S36 - page 16

    www .fmiproducts.com 1 1 1026-01J 16 Rear Left Side Front Bottom Bottom Right Side KEY NO. P ART NO. DESCRIPTION QTY . 9 106658-03 Left Refractory , T extured White Brick • 1 108164-03 Left Refractory , T extured White Herringbone • 1 106658-02 Left Refractory , T extured Red Brick • • 1 108164-02 Left Refractory , T extured Red Herringbone ...

  • FMI (V)S36 - page 17

    www .fmiproducts.com 1 1 1026-01J 17 TECHNICAL SERVICE Y ou may have furt her qu esti ons a bout i nsta llat ion, o pera tion , or tr oubl esho oting . If s o, co ntact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready . Y ou can also visit FMI PRODUCTS, LLC’s web site at www .fmiprod ...

  • FMI (V)S36 - page 18

    www .fmiproducts.com 1 1 1026-01J 18 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM ROUND TOP TERMINA TIONS RT -8DM, RTL-8DM ROUND TOP TERMINA TIONS WITH SLIP SECTION RTT -8DM, RTTL-8DM ROUND TOP TERMINA TIONS WITH LOUVERS RTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT F ...

  • FMI (V)S36 - page 19

    www .fmiproducts.com 1 1 1026-01J 19 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________ ...

  • FMI (V)S36 - page 20

    1 1 1026-01 Rev . J 02/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com ...

メーカー FMI カテゴリー Indoor Fireplace

FMI (V)S36のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- (V)S36の取扱説明書
- FMIの製品カード
- パンフレット
- またはFMI (V)S36の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、FMI (V)S36の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、FMI (V)S36の取り付け説明書、サービスマニュアル、簡易説明書、またはFMI (V)S36のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、FMI (V)S36の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

FMI (V)S36デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFMI (V)S36を使用するのを助ける技術的文書のことです。説明書は通常、全てのFMI (V)S36ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

FMIの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. FMI (V)S36の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFMI (V)S36の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。FMI (V)S36に関してこのドキュメントで見つけることができる全てのヒントの目次
3. FMI (V)S36デバイスの基本機能を使うにあたってのヒント。 FMI (V)S36のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。FMI (V)S36に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFMI (V)S36のメーカー/サービスへの連絡先に関する情報。

FMI (V)S36についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFMI (V)S36の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFMI (V)S36で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)