    Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS ? ...

  • Desa VCGF30PR - page 2

    2 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. 3. If you smell gas • shut off gas supply • d ...

  • Desa VCGF30PR - page 3

    3 104637 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New Y ork, NY 10018 National Fir ...

  • Desa VCGF30PR - page 4

    4 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. D ...

  • Desa VCGF30PR - page 5

    5 104637 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorl ...

  • Desa VCGF30PR - page 6

    6 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one withi ...

  • Desa VCGF30PR - page 7

    7 104637 OWNER’S MANUAL INST ALLA TION CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in ...

  • Desa VCGF30PR - page 8

    8 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® Figure 9 - Placing Hearth Base Accessory Against Wall Figure 10 - Installing Cabinet Mantel Electrical Outlet Hearth Base Flexible Gas Line Gas Line Access Hole Cabinet Mantel INSTALLATION CLEARANCES WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceilin ...

  • Desa VCGF30PR - page 9

    9 104637 OWNER’S MANUAL 35 1/2" 17 3/4" 33" 39 3/8" 27 7/8" 55 5/8" 35 1/2" INST ALLA TION Continued Figure 12 - Inserting Fireplace Into Cabinet Mantel Figure 11 - Location of Nailing Flanges Nailing Flanges Continued 10. Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth ...

  • Desa VCGF30PR - page 10

    10 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® 13" 16" 19" 21" 2 1 /2" 6" 8" 10" Minimum Non- Combustible Material Supplied Firebox Hood Must Be Used at All Times From External Regulator (11" W.C. to 14" W.C. Pressure) Figure 18 - Gas Connection CAUTION: Use only new, black iron or steel pipe. Inte ...

  • Desa VCGF30PR - page 11

    11 104637 OWNER’S MANUAL Installation Items Needed • 5/16" hex socket wrench or nut-driver • Phillips screwdriver • sealant (resistant to propane/LP gas, not provided) 1. Remove front window assembly . Lo- cate two phillips-head screws at top corners of front window assembly . Re- move and save these screws. Carefully lift front window ...

  • Desa VCGF30PR - page 12

    12 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at ...

  • Desa VCGF30PR - page 13

    13 104637 OWNER’S MANUAL O F F P I L O T O N H I L O Figure 24 - Installing One Piece Log Set Chassis "U"-shaped Cutout in Chassis One Piece Log Set One Piece Log Set Burner Ports Figure 25 - Installing One Piece Log Set (Top View) Figure 26 - Installing Fireplace Front Window Assembly WARNING: After installation and periodically therea ...

  • Desa VCGF30PR - page 14

    14 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® Figure 28 - Pilot O F F P I L O T O N L O I H AUTO ON OFF Note: Y ou may be running this heater for the f irst time after hook- ing up to gas supply . If so, the con- trol knob may need to be pr essed in for 30 seconds or mor e. This will al- low air to bleed fr om the gas system. 7. With contr ol kno ...

  • Desa VCGF30PR - page 15

    15 104637 OWNER’S MANUAL WARNING: Make sure the se- lector switch is in the OFF posi- tion when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position. TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE 1. Follow steps 1 thr ough 6 under Light- ing Instructions , page 14. 2. ...

  • Desa VCGF30PR - page 16

    16 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® Figure 32 - Correct Pilot Flame Pattern Figure 33 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not prop- erly ...

  • Desa VCGF30PR - page 17

    17 104637 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor ...

  • Desa VCGF30PR - page 18

    18 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit White powder residue forming within burn ...

  • Desa VCGF30PR - page 19

    19 104637 OWNER’S MANUAL TROUBLESHOOTING Continued POSSIBLE CAUSE 1. Metal expanding while heating or con- tracting while cooling 1. Fireplace burning vapors from paint, hair spray , glues, cleaners, chemicals, new carpet, etc. (see IMPORT ANT statement above) 2. Gas leak. See W arning statement above 1. Not enough fresh air is available 2. Low l ...

  • Desa VCGF30PR - page 20

    20 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® SPECIFICA TIONS VCGF30PR Remote Ready Btu (Variable) 20,000/30,000 Type Gas Propane/LP Only Ignition Piezo Pressure Manifold 7.9" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum* 11" Shipping Weight 124 lbs. * For input adjustment TECHNICAL SER VICE You may have further quest ...

  • Desa VCGF30PR - page 21

    21 104637 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleanin ...

  • Desa VCGF30PR - page 22

    22 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® ACCESSORIES EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. SLIM HEARTH BASE (Not Shown) G3005J Series - Jade Marble Laminate G3005S Series - Sandstone Marble Laminate G3005B Series - Black Onyx Marble Laminate The slim hearth b ...

  • Desa VCGF30PR - page 23

    23 104637 OWNER’S MANUAL ACCESSORIES Continued LAMINATE TRIM FOR HEARTH OR MANTEL G3002J Series - Jade Marble Laminate Mantel Trim G3003J Series - Jade Marble Laminate Hearth Base Trim G3002S Series - Sandstone Marble Laminate Mantel Trim G3003S Series - Sandstone Marble Laminate Hearth Base Trim G3002B Series - Black Onyx Marble Laminate Trim G3 ...

  • Desa VCGF30PR - page 24

    24 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® ILLUSTRA TED PA R T S BREAKDOWN REMOTE READY CATALYTIC MODEL VCGF30PR 17 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 14 13 25 15 16 21 11 10 19 19 20 19 23 24 22 18 27 28 ...

  • Desa VCGF30PR - page 25

    25 104637 OWNER’S MANUAL P ARTS LIST REMOTE READY CATALYTIC MODEL VCGF30PR KEY NO. PART NUMBER DESCRIPTION QTY. 1 102785-03 Log, Golden Oak 1 2 103778-01 ODS Pilot (NG) 1 3 098249-01 ODS Nut 2 4 099387-03 Pilot Tube 1 5 104894-02 Burner Outlet Tube 1 6 102843-01 Burner Clip 1 7 099056-21 Burner Orifice Injector 1 8 104816-01 Burner 2 9 M11084-38 ...

  • Desa VCGF30PR - page 26

    26 104637 UNVENTED PROP ANE/LP GAS FIREPLACE ® ILLUSTRA TED PA R T S BREAKDOWN FIREPLACE VCGF30PR 4 26 24 25 24 11 14 8 14 3 14 2 22 21 23 23 10 17 13 5 16 15 18 9 1 27 19 6 7 28 5 5 20 12 ...

  • Desa VCGF30PR - page 27

    27 104637 OWNER’S MANUAL P ARTS LIST FIREPLACE VCGF30PR This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357-03 Top Outer Casing 1 2 104895-01 Outer Casing 1 3 104640-01BR Right Front Side As ...

  • Desa VCGF30PR - page 28

    LIMITED WARRANTY VENT-FREE PROPANE/LP GAS FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this ...

メーカー Desa カテゴリー Indoor Fireplace

Desa VCGF30PRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VCGF30PRの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa VCGF30PRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa VCGF30PRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa VCGF30PRの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa VCGF30PRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa VCGF30PRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa VCGF30PRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa VCGF30PRを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa VCGF30PRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa VCGF30PRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa VCGF30PRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa VCGF30PRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa VCGF30PRデバイスの基本機能を使うにあたってのヒント。 Desa VCGF30PRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa VCGF30PRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa VCGF30PRのメーカー/サービスへの連絡先に関する情報。

Desa VCGF30PRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa VCGF30PRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa VCGF30PRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)