    Water heat ers for u se with Natural an d L.P.G. GWH 425 EF Flow Modulat ed wit h Elec t ronic Ignit ion and Power V ent ing Suit able for heat ing pot able w ater only - Not a pproved fo r spac e heat ing purpose s (Intend ed for vari able flow a pplicatio ns with stea dy cold wa ter inlet t emperatu res) GWH- 425-EF -N GWH- 425-EF -L 6 720 607 01 ...

  • Bosch GWH 425 EF - page 2

    2 6 720 607 017 WARNING : Improper installation, adjustment , alteration , service or maintenance can c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the use ...

  • Bosch GWH 425 EF - page 3

    3 6 720 607 017 425 EF LP and 425 EF NG Specifications W ater C onnection 1 /2” Thread fitting N PT H x W x D 29 3/ 4” x 1 8 1 / 4” x 8 3/ 4" V ent 4” Gas C onnection 1 /2” N PT thread Min. W ater Pressure 1 8 Psi Max. W ater Pressure 1 50 Psi Shipping W eight 50.6 LB Net W eight 44 LB 2.3 G P M at 90 ° rise 4.6 G P M at 45 ° rise ...

  • Bosch GWH 425 EF - page 4

    4 6 720 607 017 M I N I M U M I N S T ALLA TIO N C LE AR AN C E S F R O M C O M B U STI B LE AN D N O N CO M B U STI B LE MA TE R IAL S F O R AL C OVE O R C L O SET I N ST ALLA TI O N S FR O NT VI EW S I D E VI EW MO DE L 425 E F * On a combustible wall surface the unit should be mounted away from the wall to provide adequate clearance of the vent ...

  • Bosch GWH 425 EF - page 5

    5 6 720 607 017 G E N E R AL R U LE S T O FOLL O W FOR SAF E OP E R A TION 1. Y ou should follow these instructions when you inst all your heater . In the United St ates : The installation must conform with local codes or, in the absence of local codes , the National Fuel Gas Code AN S I Z223. 1 / N F P A 54. In Canada: The Installation should conf ...

  • Bosch GWH 425 EF - page 6

    6 6 720 607 017 COMBUSTION AIR REQUIREMENTS The 425 E F water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components. This Installation Manual specifies the vent length requirements and the amount o ...

  • Bosch GWH 425 EF - page 7

    7 6 720 607 017 Fig. 3 - Incandescent Part icle T ray Illust ration The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 3. SCREWS INCANDESCENT P ARTICLE TRA Y Fig. 2 - Mounting the Heater WAL ...

  • Bosch GWH 425 EF - page 8

    8 6 720 607 017 VENTING WARNING: Do not reduce the vent pipe size and do not common vent with any other vented appliance or stove. This appliance must be vented horizontally to the outside with a sealed 4” single wall vent pipe. The appliance’s flue gasses are under positive pressure and must travel through a single wall 4” pipe that is seale ...

  • Bosch GWH 425 EF - page 9

    9 6 720 607 017 Fig 4: S ome V enting Guide Suggest ions An approved side wall vent terminal must be used when the water heater is vented through a side wall. Locate in accordance with AN SI Z223. 1 and local applicable codes. See Fig 5 for restrictions in location of vent terminal in relation to opening doors and windows, grade, and forced air inl ...

  • Bosch GWH 425 EF - page 10

    10 6 720 607 017 Fig 5: Side wall exit locations for mechanical draft vent terminals SOFFIT VENT HOOD 7’ MINIMUM ABOVE PUBLIC WALKW AY ONE FOOT ABOVE GRADE 3’ ABOVE ANY FORCED AIR INLET WITHIN 10’ 4’ MIN 1’ MIN 4’ MIN 4’ MIN 4’ MIN 1’ MIN VENT HOOD MUST BE MOUNTED FOUR FEET AW AY FROM DOORS AND WINDOWS VENT HOOD MUST BE MOUNTED FO ...

  • Bosch GWH 425 EF - page 11

    11 6 720 607 017 Fig. 6 - Appliance pressure regulator (with directional arrow on reverse side pointing up) GAS LINE SIZING The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure (as indicated on the rating plate and in the manual for altitude up to 2000 feet (660 meters) above sea level. On appliances being ...

  • Bosch GWH 425 EF - page 12

    12 6 720 607 017 GAS PIPING, CONNECTIONS Before connecting the gas supply, chec k the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected. In the United States : The installation must conform with local codes or , in the absence of local codes , the National Fuel Gas C ...

  • Bosch GWH 425 EF - page 13

    13 6 720 607 017 Fig.7 - Water valve and water connectors, top view W A T ER C O NNEC T IO NS Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater , the cold water inlet will be on the right and the hot water outlet on the left.. Although water piping throughout your str ...

  • Bosch GWH 425 EF - page 14

    14 6 720 607 017 ELECTRICAL CONNECTIONS WARNING: For safety reasons, disconnect the power supply to the heater before any service or testing is performed. WARNING: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code , NF P A 7 0. In Canada , all electrical wiring to the heater should ...

  • Bosch GWH 425 EF - page 15

    15 6 720 607 017 OPER A T ING INST RUC T IO NS Before operating the heater , make sure that the system is filled with water . Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water faucet after the water f ...

  • Bosch GWH 425 EF - page 16

    16 6 720 607 017 Fig. 1 2 - Charact eristic Pilot Flame Flame sensor Piezo Electrode W at e r V alve (Part # 87 07 002802): The water valve on this heater should be ser viced periodically . Lubricate component #36 on page 22 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings fresh and pushrod sliding smooth ...

  • Bosch GWH 425 EF - page 17

    17 6 720 607 017 3. Water flow is not sufficient to activate heater . W ater flow rate at faucet is below minimum flow needed to activate heater . When temperature adjustment knob is turned all the way clockwise, the model 425 EF requires 1 /2 gallon per minute flow to activate the heater. As a reference , this is a flow which would fill a quart ja ...

  • Bosch GWH 425 EF - page 18

    18 6 720 607 017 Mineral deposits can eventually (3-5 years in hard water areas) corrode the water valve parts to a point where they will need replacing. Any sign of moisture at the bleed hole is a sign that the water valve needs to be replaced immediately. 1 0. Poor circuit connect ions at t he EC O ( overheat sensor ) or the flue gas safety devic ...

  • Bosch GWH 425 EF - page 19

    19 6 720 607 017 WA T E R I S T OO HOT 1 . T emperat ure Select ion t oo high T urn the temperature adjustment knob counter-clockwise (to the left) to lower the maximum water temperature. Note: This will increase the activation flow rate. 2. Inlet water temperature is very warm (60°-75°F) Reduce inlet gas supply to lower the heaters degree rise. ...

  • Bosch GWH 425 EF - page 20

    20 6 720 607 017 ...

  • Bosch GWH 425 EF - page 21

    21 6 720 607 017 Fig . 1 5 - Diagram of 425 E F 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7 . electric control box 8. Power cord 9. on/off switch 1 0. T emperature adjustment selector 1 1 . Microswitch 1 2. Gas inlet gas pressure test nipple 1 3. Exhaust Fan ...

  • Bosch GWH 425 EF - page 22

    22 6 720 607 017 Fig. 1 6 - I NTE R IOR COM PO N E NTS D IAGR AM AN D P ARTS LI ST ...

  • Bosch GWH 425 EF - page 23

    23 6 720 607 017 Fig. 1 6 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 425 E F 1 Cover 8 705 421 775 2 Temperature a djustment knob 8 702 000 111 3 Temperature adjustment collar 8 700 403 008 4 Draft diverter 8 705 505 451 5 Heat excha nger 8 705 406 235 6 Overheat sensor (ECO) 8 707 206 040 7 Main burner 8 708 120 298 NG 7 Main burner 8 708 120 29 ...

  • Bosch GWH 425 EF - page 24

    24 6 720 607 017 Fig. 1 7 - Flow chart of 425 EF ...

  • Bosch GWH 425 EF - page 25

    25 6 720 607 017 Fift een Y ear Limit ed Warranty General B O SC H P R O water heaters are warranted by the Manufacturer ( B O SC H ) through C ontrolled Energy C orp. C ontrolled Energy Corp . ( C E C ) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applic ...

  • Bosch GWH 425 EF - page 26

    VU L C AN O T ermodomésticos S.A . Estrada de Cacia 380 1 - 8 56 Aveiro - P O RTUGAL Recycled paper © 20 04 C ontrolled Energy Corporation , W aitsfield , V T all rights reserved Replacement Parts available from North American Distributor CONTROLL E D E NE R G Y C OR P . 340 Mad River Park Waitsfield, Vermont 0 567 3 Phone 86 6-33 0-27 30 Fax (80 ...

メーカー Bosch カテゴリー Water Heater

Bosch GWH 425 EFのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GWH 425 EFの取扱説明書
- Boschの製品カード
- パンフレット
- またはBosch GWH 425 EFの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bosch GWH 425 EFの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bosch GWH 425 EFの取り付け説明書、サービスマニュアル、簡易説明書、またはBosch GWH 425 EFのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bosch GWH 425 EFの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bosch GWH 425 EFデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBosch GWH 425 EFを使用するのを助ける技術的文書のことです。説明書は通常、全てのBosch GWH 425 EFユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Boschの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bosch GWH 425 EFの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBosch GWH 425 EFの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bosch GWH 425 EFに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bosch GWH 425 EFデバイスの基本機能を使うにあたってのヒント。 Bosch GWH 425 EFのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bosch GWH 425 EFに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBosch GWH 425 EFのメーカー/サービスへの連絡先に関する情報。

Bosch GWH 425 EFについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBosch GWH 425 EFの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBosch GWH 425 EFで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)