1 1-800-352-5630 www .raritaneng. com IMPOR T ANT SAFETY I NSTRUCTIONS FOR HANDLING PURASAN ® T ABLETS AND SOLUTION W ARNING: HAZARD OF DANGEROUS CHEMICAL REACTION 1. Use ONL Y Purasan T ablets. 2. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P . - Cleans Potties and R.C. Raritan Concentrate ...
-
Raritan Engineering PST*03 - page 2
2 OPERA TION (depends on installation chosen) Single Button operation - Both toilet and Purasan are operated by one of the following options: Option #1: Switch Panel "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will mome ...
-
Raritan Engineering PST*03 - page 3
3 MAINTENANCE Use ONLY Purasan Tablets. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P. - Cleans Potties and R.C. Raritan Concentrate are the only factory-recognized cleaning products that may be used in the toilet. MAINTENANCE WARNING: Read and understand all safety instructions (including Ma ...
-
Raritan Engineering PST*03 - page 4
4 WINTERIZING T ablet Dispenser 1. Close flow metering clamp and disconnect power to water solenoid, if used, to prevent intake wa- ter from entering tablet dispenser . 2. Flush toilet and activate treatment cycle several times to leave just water in tank. 3. Carefully remove small tube from white “T” fitting or check valve from water solenoid ...
-
Raritan Engineering PST*03 - page 5
5 RECOMMISSIONINGST ART -UP Recommissioning IMPOR T ANT : Do not load T ablet Cartridge into Dispenser until system is powered and operational. Do Not Operate Purasan until T reatment Unit is filled with water . T reatment T ank 1. Reconnect hoses and open seacocks. 2. Reconnect wires and turn power on. NOTE: Purasan treatment tank must be ...
-
Raritan Engineering PST*03 - page 6
6 SPECIFICA TIONS U.S.C.G. Type I MSD Certification #159.015/106/0 Maximum Roll/Pitch Angle: 30° Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Water - fresh, salt or brackish CONVERSIONS Wire - A WG to mm 2 Feet to Meters t e e F 0 15 10 25 20 30 40 5 r e t e M 1 . 36 . 41 . 66 . 72 ...
-
Raritan Engineering PST*03 - page 7
7 INST ALLA TION MOUNTING T reatment T ank W ARNING: DO NOT locate in an ar ea where ambient temperature exceeds 120 o F (49 o C). 1 . Locate top of treatment tank at or below discharge of toilet and within six feet (1.5 m). Note: If mounting treatment tank higher than discharge. Contact Raritan 2 . Make and secure mounting frame to flat surface. 3 ...
-
Raritan Engineering PST*03 - page 8
8 INST ALLA TION Raw Water Toilets - 1. T urn off power to toilet. 2. Close intake and discharge seacocks and drain water from toilet system. 3. Disconnect intake hose from bowl elbow . 4. Remove existing bowl elbow and install new bowl elbow supplied with Purasan. 5. Insert the “T” fitting in the hose between the output of the pump and the new ...
-
Raritan Engineering PST*03 - page 9
9 WIRING WIRING W ARNING: Hazard of Shock and Fire • Always use proper wire, wir e connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect other appliances to Purasan circuit. • Make sure power is off before proceeding. • Improper wiring can damage the Circuit Board and void warranty . NO ...
-
Raritan Engineering PST*03 - page 10
10 WIRING Flushing Option #1: "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will momentarily flush the toilet. 1. Mount Switch Panel near toilet. CAUTION: Use only the Raritan #CDS (fail- ure to do so will damage to the C ...
-
Raritan Engineering PST*03 - page 11
11 TROUBLESHOOTING TROUBLESHOOTING W ARNING: After the tablet dispenser has had water added, it contains a very strong halogen solution. Always wear protective gloves and ventilate well to work on tablet dispenser . Before doing any maintenance or repairs, follow WINTERIZING/STORAGE pr ocedures No Water to tablet dispenser • Clogged check valve ( ...
-
Raritan Engineering PST*03 - page 12
12 EXPLODED P ARTS 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41-100 ...
-
Raritan Engineering PST*03 - page 13
13 EXPLODED P ARTS PURASAN PARTS LIST Item Part # Description 50 41-110 Vent Kit for Tablet Dispenser (Incl. #53, 54, & 55) 51 M3 1 #14 Brass Flat Washer (4) 52 M3 0 1/4"-20 Brass Nut (4) 41-100 Tablet Dispenser Complete (less cartridge) 41-200 T-Fitting (Incl. #33, 34, 37 &38) 42-1000 Treatment Unit Complete 12 V DC 43-1000 Treatment ...
-
Raritan Engineering PST*03 - page 14
14 DUAL INSTALLATION - “Push Button” also activates Purasan - PBS Battery 3 amp Fuse Small post on CDS to S2 and PBS CDS T o toilet positive (+) Purasan Circuit Board on T reatment tank Freshwater Solenoid valve wiring Battery DUAL INST ALLA TION IMPOR T ANT : Dual toilet installations requir e either independant operation of toilet and tre ...
-
Raritan Engineering PST*03 - page 15
15 NOTE: Discharge of raw , untreated sewage is prohibited in all U.S. waters inside the thr ee mile limit except in the Gulf of Mexico where the limit is nine miles. "Y" valves, if installed, must dir ect toilet discharge to a U.S.C.G. approved treatment system or holding tank and must be secur ed in that position while inside the three- ...
-
Raritan Engineering PST*03 - page 16
16 L405 0911kgs S pecifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 Website: www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 Mark (2) Mounting Holes Level Ac ...