Raritan Engineering Crown Head IIの取扱説明書

16ページ 0.37 mb
ダウンロード

ページに移動 of 16

Summary
  • Raritan Engineering Crown Head II - page 1

    crown head II ™ ELECTRIC MARINE TOILET OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS Manufactured after June 2002 THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. ...

  • Raritan Engineering Crown Head II - page 2

    • Push Button Switch (#164000) Press and hold switch until all waste is cleared from bowl. NOTE: Push Button Switch flushing is shown. Refer to manuals included with Toilet Control (TC12W), Raritime Solid State Timer with Solenoid (#RTC), or Flush Control (#SWF100) for operation Instructions. • No special toilet paper is required. • Water sho ...

  • Raritan Engineering Crown Head II - page 3

    MAINTENANCE Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These will cause damage to the toilet. Using C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering), will keep the bowl clean and fresh smelling. Recommend Visual In ...

  • Raritan Engineering Crown Head II - page 4

    WINTERIZING IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations. • Winterize holding tanks, plumbing, treatment systems (MSD’s), etc. independentl ...

  • Raritan Engineering Crown Head II - page 5

    Pressurized Fresh Water Model Parts Required • 1 1/2" (38mm) I.D. hose, approximately 3 feet (1m) long • Two buckets • Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close discharge seacock 2. Shut off intake water at source. 3. Turn off power to unit. 4. Disconnect and drain discharge hose. 5. Disconnect intake hoses from ...

  • Raritan Engineering Crown Head II - page 6

    INSTALLATION Parts Included All Toilets Toilet Bowl (Household or Marine) Seat and Cover Discharge pump assembly Heavy Duty Push Button Switch (#164000) Mounting pads Lower Motor Cover Sea Water Model Remote Intake Pump 3/4" Hose Barb straight fitting 3/4" Hose Barb - 90° elbow fitting Plug Fitting In-Line Strainer with fittings 3/4" ...

  • Raritan Engineering Crown Head II - page 7

    SPECIFICATIONS Base Depth: 10 7/8" (27.6cm) Height: 17 3/8" (44.1cm) Household 17" (43.2cm) Marine Base Width: 10 1/2" (26.8cm) Bowl Width: 14 3/8" (36.6cm) Household 13" (33cm) Marine Bowl Depth: 19 1/4" (48.9cm) Household 16 3/4" (42.6cm) Marine Plumbing Maximum suction of Intake pump (Maximum height above ...

  • Raritan Engineering Crown Head II - page 8

    Mounting T oilet Mounting surface must be flat and solid. IMPORTANT: Do not mount where it may be subject to shower spray or other sources of external water. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses. Make sure seat will open properly. 3. Mark location of toilet base mounting holes o ...

  • Raritan Engineering Crown Head II - page 9

    Mounting Atmospheric Vacuum Breaker (Pressurized Freshwater Model only) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. Mounting In-Line Strainer (Seawater Models Only) Make sure strainer bowl is tight. 1. Locate strainer where it will be access ...

  • Raritan Engineering Crown Head II - page 10

    INSTALLATION PLUMBING WARNING: Hazard of Flooding Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top of the vented loop must be a minimum of 4" (10cm) above the waterline at the boats greatest angle of heel (see vented loop manufacturer’s instructions). Sea Water Models must also have a ...

  • Raritan Engineering Crown Head II - page 11

    Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. 1 . Connect hose from pressurized freshwater source to a shut off valve. 2. Connect hose from shut off valve to inlet port of water solenoid valve. NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Fresh ...

  • Raritan Engineering Crown Head II - page 12

    WIRING WIRING WARNING: Hazard of Shock and Fire • Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart on page 7. • Secure wire properly. • Do not connect other appliances to toilet circuit. • Make sure power is off before proceeding. NOTE: Figures shown with installation of Push Button Switch (#164000). ...

  • Raritan Engineering Crown Head II - page 13

    Problem Possible Cause A1. Clogged or restricted discharge line. A2. Too many bends or ells in discharge line. A3. Clogged holding tank or vented loops. A4. Mineral buildup in hoses and fittings. A5. Low voltage. A6. Damage to pump wall. A7. Full holding tank. B1. Head not level. B2. Restriction in line to Intake Pump or clogged strainer. B3. Intak ...

  • Raritan Engineering Crown Head II - page 14

    Part # Description 1118 Lockwasher (4) 1222AW 90 Degree discharge (opt.) 1222B Straight discharge 1226B 1/4" - 20 S/S Hex Nut (4) 1234 Bowl Gasket 1236AW Bowl Spud Assembly 1236E Bowl Elbow 1237W Marine-size Bowl Assembly (White) (Not shown) 1238A Marine-size Seat and Cover (White) (Not shown) 1244AW Household-style Bowl Assembly, (Bone) inclu ...

  • Raritan Engineering Crown Head II - page 15

    C2M* CH55 CH92 1341 1222AW CH57 CH59 1234 CH38 1226B 1236E 1236AW 1237W, 1244AW, 1244W C246, 247 F149VT C250 CH26 CH18W CH121 CH120 F149VT CH119MW CH27 C290 1222B CH58 CH51 1118 M30 M31 161107 C253 CROWN HEAD II - EXPLODED PARTS VIEW CR1 CH34 RNI PLA14 CWPS*A PLA14 CH15DD 162410 162425 162100W 162200W 162415 162425 F162VT M23A F144 162425 162405 16 ...

  • Raritan Engineering Crown Head II - page 16

    530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 L339 0407kgs Specifications Subject to Change Without Notice Printed in U.S.A. LIMITED WARRANTY Raritan Engineering Company ...

メーカー Raritan Engineering カテゴリー Marine Sanitation System

Raritan Engineering Crown Head IIのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Crown Head IIの取扱説明書
- Raritan Engineeringの製品カード
- パンフレット
- またはRaritan Engineering Crown Head IIの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Raritan Engineering Crown Head IIの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Raritan Engineering Crown Head IIの取り付け説明書、サービスマニュアル、簡易説明書、またはRaritan Engineering Crown Head IIのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Raritan Engineering Crown Head IIの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Raritan Engineering Crown Head IIデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRaritan Engineering Crown Head IIを使用するのを助ける技術的文書のことです。説明書は通常、全てのRaritan Engineering Crown Head IIユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Raritan Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Raritan Engineering Crown Head IIの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRaritan Engineering Crown Head IIの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Raritan Engineering Crown Head IIに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Raritan Engineering Crown Head IIデバイスの基本機能を使うにあたってのヒント。 Raritan Engineering Crown Head IIのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Raritan Engineering Crown Head IIに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRaritan Engineering Crown Head IIのメーカー/サービスへの連絡先に関する情報。

Raritan Engineering Crown Head IIについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRaritan Engineering Crown Head IIの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRaritan Engineering Crown Head IIで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)