Summary
  • Tripp Lite SU10K - page 1

    1 Copyright © 2001 Tripp Lite. All rights reserved. SmartOnline TM is a registered trademark of Tripp Lite. 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 Application Services: (773) 869-1236 www.tripplite.com Owner's Manual Smar tOnline TM • SU6K (6kV A) • SU10K (10kV A) On-Line, Extended-Run UPS Systems ESP A ...

  • Tripp Lite SU10K - page 2

    2 Safety This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite SmartOnline UPS Systems. UPS Location W arnings • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight. • Install your UPS in a structurally sound area. Your U ...

  • Tripp Lite SU10K - page 3

    3 Contr ol P anels Familiarize yourself with the location and function of the front and rear panel features before installing and operating your UPS. 1. “ON/OFF” Switch: This momentary rocker switch turns the UPS System’s inverter ON and OFF. 2. “SELECT” Button: This button performs two functions: it allows you to browse through different ...

  • Tripp Lite SU10K - page 4

    4 SU10KPM SU6K SUBP SU10KBP Rear P anels ON LINE MODE ECONOMY MODE ON LINE MODE ECONOMY MODE 1 14 3 6 10 11 2 4 5 8 7 9 16 15 18 13 5 12 17 1 14 3 6 10 11 2 4 5 8 7 9 16 15 18 13 17 12 2 5 12 5 L1 L2 ...

  • Tripp Lite SU10K - page 5

    5 1. Manual Bypass Switch: This red and yellow dial is used in one step of putting the UPS in "BYPASS” mode, which must be done before performing any maintenance on the UPS with the connected load supported. (See page 12 for step-by-step instructions for going into "BYPASS.") While this switch is on "BYPASS," connected eq ...

  • Tripp Lite SU10K - page 6

    6 INVERTER OPERA TION DIP SWITCH SETTINGS (SU10KPM SHO WN) Using a small tool, set the four Inverter Opera- tion DIP Switches (located on the rear panel of your UPS, see pg. 4-5 for location) to match your input voltage, input frequency and desired operational mode. Input V oltage Selection (DIP Switches #1 & #2) (Input V oltage Select Ter mina ...

  • Tripp Lite SU10K - page 7

    7 UPS LOCA TION Move your UPS over short distances using its wheels. Stabilize the UPS by releasing the stabilizers on each side of the unit. NOTE: Do not stack the UPS Systems or external battery packs. INPUT AND OUTPUT CONNECTION WIRING SELECTION Choose appropriate cabling (depending on current carried; see chart below) to connect your UPS to an ...

  • Tripp Lite SU10K - page 8

    8 EXTERNAL B A TTER Y P A CK CONNECTION (SU6K: Optional; SU10K: Required) Since SU6K models contain internal batteries, connecting external battery packs (to extend runtime) is optional. SU10KPM models, however, do not have internal batteries and require an external battery pack connection to a SU10KBP or a SUBP. Using the supplied battery connecti ...

  • Tripp Lite SU10K - page 9

    9 B A TTER Y CONDITION VERIFICA TION When the UPS is operating from battery power, the alarm and LCD Display will both alert you to the UPS battery’s charge condition. Battery Charge Condition Alarm LCD Display FULL Short Beep (every 2 seconds) ON BATTERY BATT = XXV XX% LOW Short Beep (every 1/2 second) BATTERY LOW BATT = XXV XX% UNDER Continuous ...

  • Tripp Lite SU10K - page 10

    10 SELF-TESTING When you turn the UPS ON, it will perform a brief (about 25 second) self-test. See figure below for display sequence.* *Note: If starting from battery, the BATTERY LED will be lit and the I/P and BYPASS LEDs will not. The final LCD display in the diagram below appears when the UPS is operating normally under utility-supplied AC inpu ...

  • Tripp Lite SU10K - page 11

    11 Operation (Special Conditions) OPERA TION ON BYP ASS—V OL T A GE OUT OF RANGE While in Bypass Mode, the UPS monitors the input voltage, which on Bypass equals the output voltage. If the output voltage passes out of an acceptable range (between 15% higher and 20% lower than nominal), the UPS displays the condition on its LCD and stops supplying ...

  • Tripp Lite SU10K - page 12

    12 OPERA TION UNDER SHUTDO WN Your UPS will shut down and the LCD will display a message if it detects one of the following conditions. Note: For all conditions, the “Input,” “Output” and “Bypass” LEDs will be illuminated. Condition LCD Display Message Extended Overload (>150%) OVERLOAD 150% SHUT DOWN Output Short Circuit SHORT CIRCU ...

  • Tripp Lite SU10K - page 13

    13 RS-232 INTERF A CE This female DB9 port connects your UPS via an RS-232 cable to a workstation or server equipped with Tripp Lite software. The port uses RS-232 communications to report UPS status and power conditions. Using this port, Tripp Lite software can monitor and manage network power and automatically save open files and shut down equipm ...

  • Tripp Lite SU10K - page 14

    14 DR Y CONT A CT INTERF A CE: This female DB9 contact-closure port allows your UPS to send contact-closure signals to indicate that it is on battery back-up mode and if its batteries are running low. The port can also receive a remote shutdown signal. Pin assignment: DR Y CONT ACT INTERF ACE T ABLE UPS Operating Pin 8,3 Pin 1,3 Mode Normal OPEN OP ...

  • Tripp Lite SU10K - page 15

    15 Ser vice Service Your SmartOnline UPS is covered by the 2-year limited warranty period described below. A variety of service contracts is also available from Tripp Lite, including start- up service contracts and 3- to 5-year SafeSure on-site service contracts. For more infor mation, call T ripp Lite Customer Service at (773) 869-1233. W arranty ...

  • Tripp Lite SU10K - page 16

    16 F unction Block Diagram LEDS LCD TO RS-232 AS-400 DRY CONTACT ACCESSORY SLOT REPO AC INPUT BREAKER AC INPUT SURGE PROTECTOR INPUT FIL TER AC TO DC CONVERTER DC TO AC INVERTER STA TIC BYPA S S SWITCH OUTPUT FIL TER MANUAL BYPA S S SWITCH OUTPUT ISOLATION XFM OUTPUT BREAKER OUTPUT TERMINAL BLOCK STANDARD BATTERIES: 240 VDC SUBP EXTERNAL BATTERY CA ...

  • Tripp Lite SU10K - page 17

    17 Specifications (Note: Excluding isolation transformer) Model SU6K SU10K Input Input Voltage 156V~280V Single Phase 156V~280V Single Phase Input Frequency 50/60 Hz ± 3 Hz 50/60 Hz ± 3 Hz (selectable, pg. 7) (selectable, pg. 7) Input Current 32A 50A Inrush Current <150A <200A Power Factor (Full Load) >0.99 >0.99 Efficiency (Full Load ...

メーカー Tripp Lite カテゴリー Power Supply

Tripp Lite SU10Kのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SU10Kの取扱説明書
- Tripp Liteの製品カード
- パンフレット
- またはTripp Lite SU10Kの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Tripp Lite SU10Kの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Tripp Lite SU10Kの取り付け説明書、サービスマニュアル、簡易説明書、またはTripp Lite SU10Kのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Tripp Lite SU10Kの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Tripp Lite SU10Kデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTripp Lite SU10Kを使用するのを助ける技術的文書のことです。説明書は通常、全てのTripp Lite SU10Kユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Tripp Liteの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Tripp Lite SU10Kの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTripp Lite SU10Kの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Tripp Lite SU10Kに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Tripp Lite SU10Kデバイスの基本機能を使うにあたってのヒント。 Tripp Lite SU10Kのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Tripp Lite SU10Kに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTripp Lite SU10Kのメーカー/サービスへの連絡先に関する情報。

Tripp Lite SU10Kについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTripp Lite SU10Kの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTripp Lite SU10Kで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)