York D1NA018の取扱説明書

21ページ 0.56 mb
ダウンロード

ページに移動 of 21

Summary
  • York D1NA018 - page 1

    GENERAL YORK Model D1NA and D2NA units are cooling/heating air con - ditioners designed for outdoor installation. Only gas piping, elec - tric power and duct connections are required at the point of installation. The gas-fired heaters have hot surface to pilot ignition. The tu - bular heat exchangers are aluminized steel. This appliance is not to b ...

  • York D1NA018 - page 2

    035-18265-001-A-0202 2 Unitary Products Group T ABLE OF CONTENTS TROUBLESHOOTING T roubleshooting Chart ..................................................... 15 T ABLES No. Description Page 1 Units Application Data ................................. 3 2 Natural Gas Application Data ...................... 5 3 LP Gas Application Data ................. ...

  • York D1NA018 - page 3

    Not suitable for use with conventional venting systems. LIMIT ATIONS These units must be installed in accordance with the following national and local safety codes. 1. National Electrical Code ANSI/NFPS No. 70 or Canadian Electrical Code Part 1, C22.1 (latest editions). 2. National Fuel Gas Code Z223.1 or CAN/CGA B149.1 or .2 Installation Code. 3. ...

  • York D1NA018 - page 4

    Refer to Figure 5 for information concerning rear and bottom supply and return air duct openings. ROOF CURB On applications when a roof curb is used, the unit must be posi - tioned on the curb so the front of the unit is tight against the curb. FILTERS Single phase units are shipped without a filter and is the responsi - bility of the installer to ...

  • York D1NA018 - page 5

    Scroll compressors operate in one direction only . If a three phase scroll compressor is experiencing: • Low amperage draw • Similar discharge and suction pressures • Increased noise level then the compressor is operating in reverse. T o correct this condition, switch any two (2) line voltage leads at the contactor . Please note, single phase ...

  • York D1NA018 - page 6

    3. Use wrought iron or steel pipe for all gas lines. Pipe dope should be applied sparingly to male threads only . CAUTION: If flexible stainless steel tubing is allowed by the authority having jurisdiction, wrought iron or steel pipe must be installed at the gas valve and extend a minimum of two (2) inches outside of the unit casing. WARNING: Natur ...

  • York D1NA018 - page 7

    035-18265-001-A-0202 Unitary Products Group 7 FIG . 4 - CENTER OF GRA VITY 25 24 CENTER OF GRA VITY FRONT OF UNIT CORNER “C” CORNER “D” CORNER “A” CORNER “B” T ABLE 7 - UNIT WEIGHTS MODEL DNA UNIT SHIPPING WEIGHT (lbs.) UNIT OPERA TING WEIGHT (lbs.) CORNER OPERA TING WEIGHTS (lbs., location, see Figure 4) “A” “B” “C” “ ...

  • York D1NA018 - page 8

    035-18265-001-A-0202 8 Unitary Products Group FIG . 5 - DIMENSIONS AND CLEARANCES CLEARANCES (Minimum) Front 36" Back 0" Left Side (Filter Access) 24" Right Side 12" Below Unit 1 0" Above Unit 2 36" (For Condenser Air Discharge) 15 4 REAR SIDE RETURN AIR OPENING SIDE SUPPL Y AIR OPENING BOTTOM RETURN AIR OPENING 15 15 ...

  • York D1NA018 - page 9

    HEA TING When the thermostat calls for “HEA T”, the thermostat terminal “W” is energized, energizing the combustion air blower . After airflow is established, the air proving switch closes, the hot surface ignitor is energized and the pilot valve opens ignit - ing the pilot flame. The system will try to light the pilot for 90 seconds. After ...

  • York D1NA018 - page 10

    2. Check for correct manifold gas pressures. See “Checking Gas Input”. 3. Check the supply gas pressure. It must be within the limits shown on rating nameplate. Supply pressure should be checked with all gas appliances in the building at full fire. At no time should the standby gas line pressure exceed 10.5", nor the operating pressure dro ...

  • York D1NA018 - page 11

    3. After maintenance of the pilot assembly , always measure the resistance across the ignitor . If the resistance is greater than 10 ohms, discard the ignitor and replace it with a new ignitor . ADJUSTMENT OF TEMPERATURE RISE The temperature rise (or temperature difference between the return air and the heated air from the furnace) must lie within ...

  • York D1NA018 - page 12

    NORMAL MAINTENANCE WARNING: Prior to any of the following maintenance proce - dures, shut off all power to the unit, to avoid per - sonal injury . Periodic maintenance consists of changing or cleaning filters. Under some conditions, the main burners should be cleaned. FILTERS - Inspect once a month. Replace Disposable or clean Permanent T ype as ne ...

  • York D1NA018 - page 13

    Checking Supply Air CFM T o check the supply air CFM after the initial balancing has been completed: 1.Remove the two ¼ inch dot plugs in the duct panel. 2.Insert at least 8 inches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. 3.Using an inclined manometer , determine the p ...

  • York D1NA018 - page 14

    14 Unitary Products Group 035-18265-001-A-0202 T ABLE 1 1 - SUPERHEA T CHARGING T ABLE FOR MODEL D1NA024 OUTDOOR TEMPERATURE (F) SUPERHEA T A T COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON INDOOR WB TEMPERATURE (F) 55 57 59 61 63 65 67 69 71 73 75 65 13.9 16.5 19.0 21.5 24.1 26.6 29.2 29.7 30.3 30.9 31.5 70 9.5 12.5 15.5 18.5 21.5 24.5 27.5 28.2 2 ...

  • York D1NA018 - page 15

    Unitary Products Group 15 035-18265-001-A-0202 T ABLE 14 - SUPERHEA T CHARGING T ABLE FOR MODEL D1NA042 OUTDOOR TEMPERATURE (F) SUPERHEA T A T COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON INDOOR WB TEMPERATURE (F) 55 57 59 61 63 65 67 69 71 73 75 65 18.0 19.7 21.4 23.0 24.7 26.3 28.0 29.1 30.2 31.3 32.4 70 13.4 15.3 17.3 19.3 21.2 23.2 25.2 26.6 2 ...

  • York D1NA018 - page 16

    16 Unitary Products Group 035-18265-001-A-0202 TROUBLESHOOTING YES . T urn gas supply off . Set thermostat to SV9501 is powered (24 V AC nominal) Igniter warms up and glows red Pilot valves opens T urn gas on. Pilot burner lights? Check . Line voltage power . Low voltage transformer . Main limit (Auto reset) . Rollout limit (Manual reset) . Auxilar ...

  • York D1NA018 - page 17

    Unitary Products Group 17 035-18265-001-A-0202 FIG . 9 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPL Y) FIG . 10 - TYPICAL WIRING DIAGRAM (208/230-3-60 POWER SUPPL Y) SEE DET AIL "A" (See page 18) ...

  • York D1NA018 - page 18

    18 Unitary Products Group 035-18265-001-A-0202 FIG . 1 1 - TYPICAL WIRING DIAGRAM (460-3-60 POWER SUPPL Y) FIG . 12 - TYPICAL WIRING DIAGRAM (575-3-60 POWER SUPPL Y) (See page 18) B (See page 18) B ...

  • York D1NA018 - page 19

    Unitary Products Group 19 035-18265-001-A-0202 (AL TERNA TE) (AL TERNA TE) TYPICAL WIRING DIAGRAM NOTES (See pages 16 and 17) TYPICAL WIRING DIAGRAM LEGEND (See pages 16 and 17) FIG . 13 - WIRING DIAGRAM DET AIL “B” (460 & 575-3-60 POWER SUPPL Y) See page 17 ...

  • York D1NA018 - page 20

    20 Unitary Products Group 035-18265-001-A-0202 NOTES ...

  • York D1NA018 - page 21

    Unitary Products Group 5005 Y ork Drive, Noman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A. Copyright  by Y ork International Corporation 2000 All Rights Reserved. Supersedes: 035-18265-000-A-0801 035-18265-001-A-0202 ...

メーカー York カテゴリー Air Conditioner

York D1NA018のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- D1NA018の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork D1NA018の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York D1NA018の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York D1NA018の取り付け説明書、サービスマニュアル、簡易説明書、またはYork D1NA018のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York D1NA018の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York D1NA018デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork D1NA018を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork D1NA018ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York D1NA018の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork D1NA018の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York D1NA018に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York D1NA018デバイスの基本機能を使うにあたってのヒント。 York D1NA018のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York D1NA018に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork D1NA018のメーカー/サービスへの連絡先に関する情報。

York D1NA018についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork D1NA018の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork D1NA018で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)