Chicago Electric 90599の取扱説明書

11ページ 0.46 mb
ダウンロード

ページに移動 of 11

Summary
  • Chicago Electric 90599 - page 1

    45 W A TT SOLAR KIT Model 90599 INST ALLA TION AND SER VICE INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2003, 2009 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artw ...

  • Chicago Electric 90599 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 90599 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, installation, operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product ...

  • Chicago Electric 90599 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 90599 3. Do not wire multiple panels in series. If you need to connect two or more solar panels together , this work must be done by a qualied electrician unless they are connected through a regulator . 4. This solar panel kit is not designed for tie-in to a grid. Only a licensed el ...

  • Chicago Electric 90599 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 90599 16. Wear ANSI-approved safety goggles and heavy-duty work gloves during installation. Do not wear jewelry or metal watches when working near solar panels, wiring or batteries. 17. Handle panel with care. Glass may break or a sharp edge may be exposed during movement. 18. Keep ins ...

  • Chicago Electric 90599 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 90599 SPECIFICA TIONS Rated Output 14.5 V~ / 15 W (working) Open Circuit V oltage 23.5 OCV Adapter Outlets 3, 6, 9 and 12 VDC Note: Output will decrease as the panel gets hotter than room temperature (~70° F). Angle, solar intensity , cloud cover and other factors will effect output U ...

  • Chicago Electric 90599 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 90599 2. 6c 6d Slot 2 Slot 1 Push the T op Link Bar (6d) down to slot 2 (to lock the frame assembly). See above. 3. Determine where you want to position the Frame Assembly (6a-6d) making sure it is facing south (for maximum sun exposure) with no obstructions in front of it. The Regulat ...

  • Chicago Electric 90599 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 90599 permanently mounting the Solar panels on a rooftop. 7. Solar Panels (1) Regulator (2) lead wires Hook-Up Diagram Connect the two ring connectors at the end of the lead wires coming from the Solar Panels (1) to the Solar T erminals on the Regulator (2) . See FIGURE 1 . Be sure to ...

  • Chicago Electric 90599 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 90599 batter voltage. (It is recommended to leave the voltage display off when not monitoring the battery voltage since it consumes energy .) T welve (12) V olt batteries should charge to 13 V olts for a full charge. If the intent is to stop charging the battery , disconnect the solar ...

  • Chicago Electric 90599 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 90599 4. Plug the appropriate plug on the Multi Purpose Adapter (5) into the appliance. The adapter has 3 V olt DC, 5 V olt DC, 6 V olt DC, 9 V olt DC, and 12 V olt DC plugs. 5. Insert the plug on the other end of the wire attached to the Multi Purpose Adapter (5) into the appropriate ...

  • Chicago Electric 90599 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 90599 6. Inspect and maintain batteries according to supplier ’s instructions. Adjustment T oIncreaseEfciency: 7. In the Winter , increase the panel’ s angle by 10°. 8. In the Summer , decrease the angle by up to 10°. 9. In the Spring and Fall, keep the panel at the ang ...

  • Chicago Electric 90599 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 90599 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUT OR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR W ARRANTY OF ANY KIND T O THE BUYER TH ...

メーカー Chicago Electric カテゴリー Landscape Lighting

Chicago Electric 90599のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 90599の取扱説明書
- Chicago Electricの製品カード
- パンフレット
- またはChicago Electric 90599の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Chicago Electric 90599の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Chicago Electric 90599の取り付け説明書、サービスマニュアル、簡易説明書、またはChicago Electric 90599のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Chicago Electric 90599の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Chicago Electric 90599デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがChicago Electric 90599を使用するのを助ける技術的文書のことです。説明書は通常、全てのChicago Electric 90599ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Chicago Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Chicago Electric 90599の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははChicago Electric 90599の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Chicago Electric 90599に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Chicago Electric 90599デバイスの基本機能を使うにあたってのヒント。 Chicago Electric 90599のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Chicago Electric 90599に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるChicago Electric 90599のメーカー/サービスへの連絡先に関する情報。

Chicago Electric 90599についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもChicago Electric 90599の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがChicago Electric 90599で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)