    45 W A TT SOLAR KIT Model 90599 INST ALLA TION AND SER VICE INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2003, 2009 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artw ...

  • Chicago Electric 90599 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 90599 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, installation, operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product ...

  • Chicago Electric 90599 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 90599 3. Do not wire multiple panels in series. If you need to connect two or more solar panels together , this work must be done by a qualied electrician unless they are connected through a regulator . 4. This solar panel kit is not designed for tie-in to a grid. Only a licensed el ...

  • Chicago Electric 90599 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 90599 16. Wear ANSI-approved safety goggles and heavy-duty work gloves during installation. Do not wear jewelry or metal watches when working near solar panels, wiring or batteries. 17. Handle panel with care. Glass may break or a sharp edge may be exposed during movement. 18. Keep ins ...

  • Chicago Electric 90599 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 90599 SPECIFICA TIONS Rated Output 14.5 V~ / 15 W (working) Open Circuit V oltage 23.5 OCV Adapter Outlets 3, 6, 9 and 12 VDC Note: Output will decrease as the panel gets hotter than room temperature (~70° F). Angle, solar intensity , cloud cover and other factors will effect output U ...

  • Chicago Electric 90599 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 90599 2. 6c 6d Slot 2 Slot 1 Push the T op Link Bar (6d) down to slot 2 (to lock the frame assembly). See above. 3. Determine where you want to position the Frame Assembly (6a-6d) making sure it is facing south (for maximum sun exposure) with no obstructions in front of it. The Regulat ...

  • Chicago Electric 90599 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 90599 permanently mounting the Solar panels on a rooftop. 7. Solar Panels (1) Regulator (2) lead wires Hook-Up Diagram Connect the two ring connectors at the end of the lead wires coming from the Solar Panels (1) to the Solar T erminals on the Regulator (2) . See FIGURE 1 . Be sure to ...

  • Chicago Electric 90599 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 90599 batter voltage. (It is recommended to leave the voltage display off when not monitoring the battery voltage since it consumes energy .) T welve (12) V olt batteries should charge to 13 V olts for a full charge. If the intent is to stop charging the battery , disconnect the solar ...

  • Chicago Electric 90599 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 90599 4. Plug the appropriate plug on the Multi Purpose Adapter (5) into the appliance. The adapter has 3 V olt DC, 5 V olt DC, 6 V olt DC, 9 V olt DC, and 12 V olt DC plugs. 5. Insert the plug on the other end of the wire attached to the Multi Purpose Adapter (5) into the appropriate ...

  • Chicago Electric 90599 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 90599 6. Inspect and maintain batteries according to supplier ’s instructions. Adjustment T oIncreaseEfciency: 7. In the Winter , increase the panel’ s angle by 10°. 8. In the Summer , decrease the angle by up to 10°. 9. In the Spring and Fall, keep the panel at the ang ...

  • Chicago Electric 90599 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 90599 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUT OR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR W ARRANTY OF ANY KIND T O THE BUYER TH ...

Fabricant Chicago Electric Catégorie Landscape Lighting

Les documents que nous recevons du fabricant de l'appareilChicago Electric 90599 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Chicago Electric
- manuels d’utilisations 90599
- fiches produit Chicago Electric
- dépliants
- ou étiquettes-énergie Chicago Electric 90599
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Chicago Electric 90599.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Chicago Electric 90599, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Chicago Electric 90599. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Chicago Electric 90599.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Chicago Electric 90599, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Chicago Electric 90599 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Chicago Electric 90599.

Le manuel d’utilisation complet Chicago Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Chicago Electric 90599 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Chicago Electric 90599, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lChicago Electric 90599 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Chicago Electric 90599 - qui devraient nous aider dans les premières étapes lors de l'utilisation Chicago Electric 90599
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Chicago Electric 90599
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Chicago Electric 90599 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Chicago Electric 90599?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Chicago Electric 90599, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Chicago Electric 90599 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)