  • Miele DA 399-5 Ext - page 1

    Operating and installation instructions Cooker hood DA 396 DA 399 To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time. M.-Nr. 06 417 570 en - GB, AU, NZ ...

  • Miele DA 399-5 Ext - page 2

    Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide to the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Modes of operat ...

  • Miele DA 399-5 Ext - page 3

    Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children. Danger of suffocation! Dispose of or recycle al ...

  • Miele DA 399-5 Ext - page 4

    This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time. They contain important information on the safety, i ...

  • Miele DA 399-5 Ext - page 5

    ~ Before connecting the appliance to the mains supply, make sure that the voltage and frequency details given on the data plate correspond with the on-site electricity supply, otherwise the appliance could be damaged. Consult a qualified electrician if in any doubt. ~ The electrical safety of this appliance can only be guaranteed when continuity is ...

  • Miele DA 399-5 Ext - page 6

    ~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ This appliance may only be used in mobile installations such as ships, caravans, aircraft etc. if a risk assessment of the installation has been carri ...

  • Miele DA 399-5 Ext - page 7

    In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room. Ventilation can be maintained by air inlets which must not be blocked, in wi ...

  • Miele DA 399-5 Ext - page 8

    Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard. ~ When using the cooker hood over a gas hob, ensure that any burners in use are a ...

  • Miele DA 399-5 Ext - page 9

    ~ Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. ~ All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. ~ The appliance must not be connected to a chimney or vent flue which is in use. Neither should it be ...

  • Miele DA 399-5 Ext - page 10

    Guide to the appliance 10 ...

  • Miele DA 399-5 Ext - page 11

    a Extension piece b Tower c Canopy d Control panel e Grease filter f Recirculation grille (only for recirculation mode) g Hob lighting h Charcoal filter (special accessory for recirculation mode) i Hob lighting switch j Sliding switch for the fan To switch on, slide the switch to the required setting. Depending on the intensity of the cooking vapou ...

  • Miele DA 399-5 Ext - page 12

    The cooker hood works with . . . air extraction: The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap , the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit. Having a non-return flap fitted in the ducting ensure ...

  • Miele DA 399-5 Ext - page 13

    Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the wall socket and the plug is withdrawn, or – the fuse is withdrawn from the fused spur connection unit, or – the mains fuse is withdrawn,or – the screw-out fuse is removed (in countries where this ...

  • Miele DA 399-5 Ext - page 14

    Important for appliances with lacquered housing (special finish) It is very difficult to clean this type of surface without causing minor marks to the surface material. This can become particularly noticeable with darker colours and if there is halogen lighting in the kitchen. Controls The controls may suffer discolouration or damage if soiling is ...

  • Miele DA 399-5 Ext - page 15

    Cleaning the grease filters by hand ^ Clean the filters with a soft nylon brush in a mild solution of hot water and a small amount of washing-up liquid. Do not use undiluted washing up liquid. Do not use: – cleaning agents containing descaling agents, – powder cleaners, cream cleaners or abrasive all-purpose cleaning agents, – oven sprays. Cl ...

  • Miele DA 399-5 Ext - page 16

    Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter must be inserted in addition to the grease filters. It is designed to absorb cooking odours, and is fitted in the canopy above the grease filters. New filters can be purchased from your Miele Dealer / Chartered Agent or from the Miele Spar ...

  • Miele DA 399-5 Ext - page 17

    Changing a halogen lamp Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Ensure that – it is switched off at the wall socket and the plug is withdrawn, or – the fuse is withdrawn from the fused spur connection unit, or – the mains fuse is withdrawn,or – the screw-out fuse is removed (in countries wh ...

  • Miele DA 399-5 Ext - page 18

    DA 396 DA 399 1) Extraction 2) Recirculation 3) Ventilation grille position for recirculation 4) and 5): (5 is not required for recirculation mode cooker hoods) The shaded area represents the wall or ceiling area for the vent cut-out, and for fitting the connection socket. For recirculation mode, only a connection socket needs to be fitted. Connect ...

  • Miele DA 399-5 Ext - page 19

    Safety distance between hob and cooker hood (S) When planning the installation height of your cooker hood, the minimum safety distance between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: – 450 mm (GB), 600 mm (AU, NZ) above elect ...

  • Miele DA 399-5 Ext - page 20

    Assembly parts Installation 20 ...

  • Miele DA 399-5 Ext - page 21

    a 3 protective sheets for use when fitting the tower. b 2 hose clips for securing the exhaust ducting. c 1 reducing collar for exhaust ducting C 125 mm. d 1 non-return valve for fitting into the exhaust socket on the motor unit (for extraction mode only) e Upper retaining plate for securing the extension piece. f Middle retaining plate for securing ...

  • Miele DA 399-5 Ext - page 22

    Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this book. This is particularly crucial when using the cooker hood at the same time as a heating appliance that relies on oxygen from the sa ...

  • Miele DA 399-5 Ext - page 23

    All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable. Ensure power is not supplied to the appli ...

  • Miele DA 399-5 Ext - page 24

    , Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations. Seek approval from ...

  • Miele DA 399-5 Ext - page 25

    Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated. Condensate trap (optional extra) In addition to insulating the exhaust ducting, w ...

  • Miele DA 399-5 Ext - page 26

    In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Customer Contact Centre (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance. These are shown on the dat ...

  • Miele DA 399-5 Ext - page 27

    Total connected load ..........2 2 0W Fan motor .................1 2 0W Hob lighting ..............2x5 0W Voltage ..................A C2 3 0V Frequency .................~5 0H z Fuse rating GB .................3A AUS, NZ: Plug rating ...................1 0A Test marks .......... Electrical safety ...................... C-Tick Mark Electrically suppr ...

  • Miele DA 399-5 Ext - page 28

    Alteration rights reserved / 4209 M.-Nr. 06 417 570 / 10 ...

メーカー Miele カテゴリー Exhaust hood

Miele DA 399-5 Extのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DA 399-5 Extの取扱説明書
- Mieleの製品カード
- パンフレット
- またはMiele DA 399-5 Extの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miele DA 399-5 Extの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miele DA 399-5 Extの取り付け説明書、サービスマニュアル、簡易説明書、またはMiele DA 399-5 Extのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miele DA 399-5 Extの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miele DA 399-5 Extデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiele DA 399-5 Extを使用するのを助ける技術的文書のことです。説明書は通常、全てのMiele DA 399-5 Extユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mieleの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miele DA 399-5 Extの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiele DA 399-5 Extの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miele DA 399-5 Extに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miele DA 399-5 Extデバイスの基本機能を使うにあたってのヒント。 Miele DA 399-5 Extのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miele DA 399-5 Extに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiele DA 399-5 Extのメーカー/サービスへの連絡先に関する情報。

Miele DA 399-5 Extについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiele DA 399-5 Extの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiele DA 399-5 Extで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください