Unigreen 22の取扱説明書

36ページ 1.71 mb
ダウンロード

ページに移動 of 36

Summary
  • Unigreen 22 - page 1

    10/2007 USE AND MAINTENANCE MANUAL HERBICIDE SPRAYERS TRACTOR-MOUNTED SPRAYERS CAMPO 11 - 16 - 22 - 32 DSP 11 - 16 - 22 - 32 Read this manual carefully before use ISO Color code GB ...

  • Unigreen 22 - page 2

    2 unigreen Summar y 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL ..................................... 4 1. 1 COMPOSITION OF THE MANU AL ............................................................................................................. 4 1.2 GU ARANTEE ............................................................................... ...

  • Unigreen 22 - page 3

    unigreen 3 5.4 LIFTING ................................................................................................................................................... 2 2 5. 5 DISTR UBUTION WITH HERBICIDE BOOM .............................................................................................. 2 2 5.5.1 DESCRIPTION OF TYPE OF JETS ... ...

  • Unigreen 22 - page 4

    4 unigreen Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the operator and the environment, nevertheless there are still some residual risks due to the nature of the product used. For this reason we recommend reading all of this manual to avoid making mistakes ...

  • Unigreen 22 - page 5

    unigreen 5 2 SAFETY REGULATIONS AND RESIDUAL RISKS In relation to safety, the following terms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person. Person exposed: any person who has their body or any part of their body in a dang ...

  • Unigreen 22 - page 6

    6 unigreen 2. 1 INTENDED USE The sprayer in this series is built for agricultural use. The materials used are resistant to normal chemical products used in agricultural spraying (or herbicides) at the time of construction. Any other use is not allowed and the manufacturer is not responsible for any damage caused by aggressive, dense or sticky chemi ...

  • Unigreen 22 - page 7

    unigreen 7 Refer to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone. (see point 8.5) c) Due to the complex ...

  • Unigreen 22 - page 8

    8 unigreen 3 . 2 NOISE LEVEL OF THE MACHINE Use earmuffs to protect your ears when using the machine, Sprayers that are equipped with just a pump and hydraulic plant A COUSTIC PO WER LEVEL emitted by the machine: 106,0 dB A A COUSTIC PRESSURE LEVEL A T THE OPERA T OR’S POSITION emitted by the machine: 91,4 dBA Spra yers that are equipped of air s ...

  • Unigreen 22 - page 9

    unigreen 9 4.1.1 W ORK ST A TIONS The use of this machine does not envisage an operator standing constantly near the same, the oper ator nor mally sits in the cab of the tractor . During calibration and maintenance operations the operator will be working near the machine at ground level (for all the calibration and maintenance operations refer to t ...

  • Unigreen 22 - page 10

    10 unigreen 4.3.1 T O WED SPRA YERS P ARKING Don’t stand the sprayers on unstable ground or steep slopes, the machine is designed to be parked safely on compact ground with a slope of up to 8.5° using the relevant chocks (FIG. 3) in the following way: - Machine parked with drawbar uphill (max 8.5°), place the chocks behind the wheels. - Machine ...

  • Unigreen 22 - page 11

    unigreen 11 4.4.2 HOOK VERSION (HOMOLOGA TED) = Check that the weight on the hook can be supported by the tractor (the maximum weights on the drawbar are indicated in the fittings tables N° 12 pages 33-34). = If the machine is coupled to the tractor by a tow hook, adjust the height of the hook to keep the tank of the sprayer horizontal. = When you ...

  • Unigreen 22 - page 12

    12 unigreen 4.4.5 HYDRA ULIC CONNECTION T O THE DISTRIBUT ORS The machines that need a hydraulic connection to drive the herbicide booms are equipped with 1/2", “Push-Pull”, quick-fit male couplings. Y ou can connect the pipes by simply pushing them in, making sure you: - proceed only with the engine turned off; - lower any tools connected ...

  • Unigreen 22 - page 13

    unigreen 13 4 . 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the man ufacturer . The pump can be identified by the ratings plate on the same; the main data on the pressure and delivery are easy to find on this plate. Normally the pumps mustn’t exceed 550 RPM; a higher speed won’t improve ...

  • Unigreen 22 - page 14

    14 unigreen 4 . 8 PRESSURE REGULA TOR T o use the pressure regulator , follo w the instr uctions in the enclosed handbook scrupulously . The pressure regulator controls all of the most impor tant spra ying functions, the thorough knowledge of its functions makes work easier and more precise. The working pressure and the maximum pressure of the spra ...

  • Unigreen 22 - page 15

    unigreen 15 Pressure regulators with a volumetric valve (RPN-DPR-ERGO-REMO) Adjusting the maximum pressure valve = put main control A in the drain position (“OFF”). = loosen the hand wheel of maximum pressure valve B completely (anticlockwise). = open volumetric v alve E completely . = star t the pump by activ ating the power-takeoff of the tr ...

  • Unigreen 22 - page 16

    16 unigreen 4 . 1 1 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks. The pipe used for filling must never come into contact with the liquid ...

  • Unigreen 22 - page 17

    unigreen 17 4.12.3 PREMIXER ON HOPPER WITH TIN W ASHER (OPTIONAL) Campo 22-32 machines come equipped with the T OP-MIX S-41 premixer (FIG. No . 10); this v ersion of the premixer allo ws independent adjustment of pressure knob , av oiding having to change the work settings of the machine every time you have to do the premixing. T o mix the product ...

  • Unigreen 22 - page 18

    18 unigreen 4.12.4 T OP-MIX PREMIXER FOR CAMPO 11-16-22E (OPTIONAL) The T op-Mix S41 premix er is also available f or Campo 11-16-22E machines as an optional feature. Its operation is slightly different from the standard version on Campo 22-32 machines; this version of the premixer maintains an independent pressure setting, eliminating the need to ...

  • Unigreen 22 - page 19

    unigreen 19 4 . 1 3 W ASHING THE SPRA YER Thoroughly wash the machine after each treatment pumping clean water through the circuit and clean the suction and delivery filters. W ar ning: Dir ty equipment is very dangerous for the people and en vironment. Discharging the residues of washing in the environment without taking precautions is forbidden a ...

  • Unigreen 22 - page 20

    20 unigreen Elettroil connection to quick-fit couplings of the tractor T a nk Hydraulic pump Oil level 5 HORIZONT AL BOOMS FOR HERBA CIOUS CUL TIV A TIONS 5 . 1 HYDRA ULIC HERBICIDE BOOMS These are made in of steel painted with epo xy paint or hot galvanised. The jet booms are made of stainless steel with the jets mounted normally ever 50 cm. All o ...

  • Unigreen 22 - page 21

    unigreen 21 distributor of the sprayer only when the cylinders are being used. We recommend having qualified personnel do any adjustments. 5 . 2 AIR-ASSISTED BOOMS These are booms that use air to make the treatment more effective and decrease wind drift. They are equipped with a fan (normally hydraulic) and an AIR- SLEEVE that transports the airflo ...

  • Unigreen 22 - page 22

    22 unigreen 5 . 4 LIFTING The lifting devices are very useful to adjust the height of the boom on the basis of the height of the vegetation to be treated. The height of the boom is adjusted as follows: = the hydraulic version has a double-effect cylinder controlled by a special parachute stop valve. = to lift and lower the boom use the control on t ...

  • Unigreen 22 - page 23

    unigreen 23 T o meet par ticular requirements UNIGREEN can supply booms with different spaces between the nozzles and setups suitable for running at pressures ov er 20 bar . See the table below for the data conversion. USEFUL INFORMA TION During the distribution of the product watch the pre-established speed and pressure, following the data in the ...

  • Unigreen 22 - page 24

    24 unigreen 5 . 6 MARKER The marker indicates the zone where the treatment has been applied. It produces a chemical foam that doesn’t damage the crops, which is deposited on the ground and disappears after roughly an hour . The marker is an accessory available on request. For the use and maintenance of the system follow the instructions in the sp ...

  • Unigreen 22 - page 25

    unigreen 25 8 MAINTENANCE (T o be done with the machine and cardan shaft stopped) The maintenance of the spra yer is essential f or maintaining a high lev el of safety . Also consult the single handbooks of the main components of the spra yer . All of the maintenance operations and repairs must be carried out with the machine and cardan shaft stopp ...

  • Unigreen 22 - page 26

    26 unigreen 8 . 7 PUTTING BA CK INTO SER VICE AFTER WINTER LA YUP Before using the machine again after a long period of inactivity you should perform some general checks, following the instructions in point 4.4 and drain any antifreeze. Never start the shaft of the pump if you think there ma y by ice inside. T o check this, make sure you can turn t ...

  • Unigreen 22 - page 27

    unigreen 27 ...

  • Unigreen 22 - page 28

    28 unigreen Caratteristiche ugelli a vent aglio ISO (portat a in Litri/ett aro, con distanza getti 50cm., alla velocità indicat a) ISO fan nozzles tip s specifications (delivery in Lt./ha, with nozzles distance 500 mm., at the st ated speed) ISO T AB.1 CHARA CTERISTICS NOZZLES ISO Km/hKm/h Km/h Km/hKm/h K m/ h 5678 9 1 0 0,48 115 96 82 7 2 64 5 8 ...

  • Unigreen 22 - page 29

    unigreen 29 T AB.2 CHARA CTERISTICS NOZZLES CONICAL ISO Km/h Km/h Km/h Km/h Km/h Km/h 56789 1 0 0,48 115 96 82 72 64 58 2 0,59 142 118 101 89 79 71 3 0,68 163 136 117 102 91 82 4 0,76 182 152 130 114 101 91 5 0,83 199 166 142 125 111 100 6 0,90 216 180 154 135 120 108 7 0,96 230 192 165 144 128 115 8 1,07 257 214 183 161 143 128 10 1,18 283 236 202 ...

  • Unigreen 22 - page 30

    30 unigreen T AB.3-4 CAP ACITY HAND LANCES T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR MITRA SPRA Y GUN note: standard Ø2,5 nozzle DIAMETER NOZZLE Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0 PRESSURE (BAR) JE T CAP ACITY ( L t / m in ) 15 cone 2,45 3,60 4,60 5,90 6,90 8,10 9,20 11,5 di r e c t j et 2,50 3,80 5,10 7, ...

  • Unigreen 22 - page 31

    unigreen 31 DISTANCE BETWEEN 22 , 533 , 544 , 555 , 566 , 57 8 9 1 0 THE ROWS (m) SPEED (Km/hour) MINUTES/HECTARE 2,0 150 12 0 100 87 75 67 60 55 50 45 43 37 33 30 2,5 120 96 80 70 60 53 48 44 40 36 34 30 26 24 3,0 100 80 66 58 50 44 40 36 33 30 28 25 22 20 3,5 86 69 57 50 43 38 34 31 29 26 24 21 19 17 4,0 75 60 50 44 37 33 30 27 25 22 21 19 17 15 ...

  • Unigreen 22 - page 32

    32 unigreen T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERATION 8 h 50 h 300 h END OF SEASON Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 Check and clean the suction 0 and delivery filters Check the pump fixing feet 0 and screws in general Check the diaphragm and the oil X (1) X ...

  • Unigreen 22 - page 33

    unigreen 33 TAB.12A ALLOWED FITTINGS 2006 TA B . 12 a C A M P O 11 C A M P O 16 C A M P O 22 C C A M P O 22 P - S C A M P O 32 C C A M P O 32 P - S D SP 11 D SP 16 D SP 22 C D SP 22 P - S D SP 32 C D SP 32 P -S " " B P 171 X X X X X " " B P 235 X X X X X X X " " B P 280 X X X X X X " " B P 265 X XXX " &q ...

  • Unigreen 22 - page 34

    34 unigreen TAB.12B ALLOWED FITTINGS 2006 TA B . 12 b CA MP O - DS P 1 1 CA MP O- DSP 1 6 CA M PO- DS P 2 2 C CA MP O - DS P 2 2 P- S CA MP O- DS P 3 2 C CA MP O - DS P 3 2 P- S VE N T O VE N T O VE N T O VE N T O VE N T O VE N T O " " BP 2 35 X X X " " BP 2 80 X X X X X X " " BP 2 65 X X X X X X " " BP 3 05 ...

  • Unigreen 22 - page 35

    unigreen 35 GENERA TORE D'ARIA CALDA UGELLO OTTIMALE Ø 5÷6 mm Leister Kombi "TRIAC" - In caso di danneggiamento si consiglia di procedere alla riparazione procurandosi un generatore d'aria calda (reperibile presso qualsiasi idraulico) e chiedendo alla Uni- green il seguente Kit : Bacchette di polietilene lineare (vari co- lori ...

  • Unigreen 22 - page 36

    Descriptions, indicative illustrations, UNIGREEN S.P.A. reserves the right to make variations or modifications without prior warning. via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group UNI 16100005F - GB Feb.-08 ...

メーカー Unigreen カテゴリー Spreader

Unigreen 22のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 22の取扱説明書
- Unigreenの製品カード
- パンフレット
- またはUnigreen 22の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Unigreen 22の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Unigreen 22の取り付け説明書、サービスマニュアル、簡易説明書、またはUnigreen 22のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Unigreen 22の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Unigreen 22デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnigreen 22を使用するのを助ける技術的文書のことです。説明書は通常、全てのUnigreen 22ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Unigreenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Unigreen 22の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnigreen 22の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Unigreen 22に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Unigreen 22デバイスの基本機能を使うにあたってのヒント。 Unigreen 22のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Unigreen 22に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnigreen 22のメーカー/サービスへの連絡先に関する情報。

Unigreen 22についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnigreen 22の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnigreen 22で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)