    P33 Zero Clear ance Direct V ent Gas Fireplace Model P33-NG4 P33-LP4 Fuel T ype Natural Gas Propane Minimum Supply Pressure 5” W .C. (1.25 kPa) 12” W .C. (3.00 kPa) Manifold Pressure - High 3.8” W .C. (0.95 kPa) 1 1” W .C. (2.74 kPa) Manifold Pressure - Low 1.1” W .C. (0.27 kPa) 3.3” W .C. (0.82 kPa) Ori fi ce Size #44 DMS - 0-2000ft # ...

  • Regency 946-523/P - page 2

    Model P33-NG4 w/ Contemporary Faceplate P33-LP4 w/ Contemporary Faceplate Fuel T ype Natural Gas Propane Minimum Supply Pressure 5” W .C. (1.25 kPa) 12” W .C. (3.00 kPa) Manifold Pressure - High 3.8” W .C. (0.95 kPa) 1 1” W .C. (2.74 kPa) Manifold Pressure - Low 1.1” W .C. (0.27 kPa) 3.3” W .C. (0.82 kPa) Ori fi ce Size #47 DMS #56 DMS ...

  • Regency 946-523/P - page 3

    F r aming and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. T otal facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick. 2) Frame in the enclosure for the unit with framing material. 3) For exterior walls, insu ...

  • Regency 946-523/P - page 4

    P33 Gas Fireplace Combustible Mantels with Contemporar y F aceplate Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below . Mantel may be installed anywhere in the shaded area or higher . Mantel Le g Clearances with Contemporar y F ...

  • Regency 946-523/P - page 5

    6-7/8" (173mm) dia. Flue pipe 4" (102mm) dia. flue pipe W all Thimble (2 pc) T ermination Cap (Part# 946-523/P) AstroCap TM spring spacer FPI Direct V ent System (Flex) Horizontal T erminations Only This venting system, in combination with the P33 Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W ...

  • Regency 946-523/P - page 6

    Rigid Pipe V enting Horizontal or V ertical T erminations V enting Ar r angements - V er tical T er minations Rigid Pipe System (Propane & Natural Gas) The P33 is approved for a maximum 40 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. The lightly shaded area, 6 8 2 0 4 10 0 2 4 6 40 8 10 12 14 16 18 20 22 24 2 ...

  • Regency 946-523/P - page 7

    V er tical V enting with Two (2) 90° Elbo ws - Initial v er tical section. T wo 45° elbows = One 90° elbow Option V H V+ V1 Maximum total pipe: length, of all sections, must not exceed 30 feet. T otal horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 1’ Min. 4’ Max. 2’ Min. B) 2’ Min. 5’ ...

  • Regency 946-523/P - page 8

    V enting Ar r angements - Horizontal T er minations This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45° and one 90° elbow (two 45º elbows equal one 90° elbow). Note: Must use optional rigid pipe adapter (Part # 510-994) when using Rigid Pipe. • Maintain clearances t ...

  • Regency 946-523/P - page 9

    Horizontal V enting with Two (2) 90° Elbows - Initial v er tical section. T wo 45° elbows = One 90° elbow Option V H+ H1 Maximum total pipe: length, of all sections, must not exceed 30 feet. T otal horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 1’ Min. 3’ Max. B) 2’ Min. 4’ Max. C) 3’ ...

  • Regency 946-523/P - page 10

    Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (1 1m) Air Intake Co-linear DV V ertical T ermination Cap # 946-529 Co-Linea Flex Adapter with Kit# 946-563 Outer Pipe with Kit# 946-563 Inner Pipe Adapter with Kit# 946-563 Rigid Pipe Adapter # 510-994 Pipe Length 45 Elbow o V er tical ter minatio ...

メーカー Regency カテゴリー Indoor Fireplace

Regency 946-523/Pのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 946-523/Pの取扱説明書
- Regencyの製品カード
- パンフレット
- またはRegency 946-523/Pの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Regency 946-523/Pの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Regency 946-523/Pの取り付け説明書、サービスマニュアル、簡易説明書、またはRegency 946-523/Pのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Regency 946-523/Pの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Regency 946-523/Pデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRegency 946-523/Pを使用するのを助ける技術的文書のことです。説明書は通常、全てのRegency 946-523/Pユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Regencyの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Regency 946-523/Pの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRegency 946-523/Pの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Regency 946-523/Pに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Regency 946-523/Pデバイスの基本機能を使うにあたってのヒント。 Regency 946-523/Pのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Regency 946-523/Pに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRegency 946-523/Pのメーカー/サービスへの連絡先に関する情報。

Regency 946-523/Pについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRegency 946-523/Pの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRegency 946-523/Pで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)