    GE Digital Energy Power Quality Installation Guide Digital Energy™ SNMP / WEB ADAPTER P/N 1018959 3-ph SNMP/Web plug-in adapter P/N 1019070 1-ph SNMP/Web plug-in adapter P/N 23954 SP SNMP/Web plug-in adapter P/N 1019071 1-ph SNMP/Web external adapter GE Cons umer & In dustrial SA General Electric Company CH – 6595 Riazzino (Locarno) Switzer ...

  • GE 1018959 - page 2

    Model: 3-ph SNMP/Web plug-in adapter 1-ph SNMP/Web plug-in adapter SP SNMP/Web plug-in adapter 1-ph SNMP/Web external adapter Date of issue: 13.05.2008 File name: ISG_CN T_SNM_BAS_CRD_V012 Revision: 1.2 Identification N o. P/N 1018959 P/N 1019070 P/N 23954 P/N 1019071 Up-dating Revision Concerns Date 1.0 First Issue 20.12.2007 1.1 First RELEASED Is ...

  • GE 1018959 - page 3

    Dear Customer , We thank you for selecting our products and are pleased to count you amongst our very valued customers at GE . We trust that the use of the SNMP/Web adapters for our Uninterruptible Power Supply systems, developed and produced to the highest standards of quality, will give you complete satisfaction. Please read carefully the Install ...

  • GE 1018959 - page 4

    Table of contents Page 1 SAFETY RULES ............................................................................................................................... .................. 5 1.1 WARNINGS AND CAUTIONS ............................................................................................................................... ......... ...

  • GE 1018959 - page 5

    1 SAFETY RULES With this document, GE gives to the user all the necessa ry inform ation about the correct insta llation of the SNMP/Web adapters. Please read carefu lly this Instal lation Manual before installing or operating the adapters. We recommend that this manual be kept next to the UPS for future references. If any problems are encountered w ...

  • GE 1018959 - page 6

    1.1 WARNINGS AND CAUTIONS GENERAL • Always strictly observe the “ UPS Sa fety Rules ” • Check carefully the integr ity of the equipment. In case you note some visible damage, do no t install the equipment but contact the nearest Se rvice Centre . • WARNING: RISK OF ELECTR ICAL SHOCK. Do not remove any UPS covers; there are no user service ...

  • GE 1018959 - page 7

    ENVIRONMENT • Please take care of packaging mate rial: either save it for later use or recy cle/dispose in compliance with local and other applicable regulations. • The SNMP/Web adapt ers contain a removab le, Lithiu m coin-c ell bat tery . Dispose of used batteries in compliance with local and other applicable regulations. WARNING ! The UPS co ...

  • GE 1018959 - page 8

    1.2 EMC COMPATIBILITY 1-ph SNMP/Web plug-in adapter (P/N 1019070) 1-ph SNMP/Web external adapter (P/N 1019071) This device has been tested for co mpliance with the following standards: • EN 61000-6-2 • EN 61000-6-3 NOTE: This equipment has been tested and found to comp ly with the limits for a Class B digital device, pursuant to Part 15 of the ...

  • GE 1018959 - page 9

    2 INTRODUCTION 2.1 CHECKING PACKAGE CONT ENTS The SNMP/Web adapters are delivered in d i fferent kits accord ing to the model. 3-ph SNMP/Web plug-in adapter (P/N 1018959) • 3-ph SNMP/Web plug-in adapter, with pre-installed standard front panel • A front panel designed for LP33 Series UPSs • Square plates for older SitePro UPSs • Mounting sc ...

  • GE 1018959 - page 10

    • Third Party License ReadMe • CD-ROM AC ada p ter Serial cable 2.2 OVERVIEW 3-ph SNMP/Web plug-in adapter (P/N 1018959) LP 33 Series UPS SitePro / SG Serie s UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100 Active LAN UPS 4 3 2 1 1 2 3 4 • 1 – R ...

  • GE 1018959 - page 11

    • 1 – RJ45 Connector Ethernet connection, 10Base-T or 100B ase-TX • 2 – LEDs Ref. specific section • 3 – RS-232 port Local console connection (115200-N-8-1) • 4 – Reset b utton HW reset • 5 – RJ11 Connector Contact interface, open-collect or output SP SNMP/Web plug-in adapter (P/N 23954) • 1 – RJ45 Connector Ethernet connect ...

  • GE 1018959 - page 12

    LEDs The various front panel LEDs have the following meaning: • LAN / Netlink Status Meaning Off No LAN connection detected LAN connection establishe d, no communication On LAN connection established, receive or transmit active Blink • UPS / Fail Status Meaning OK / No Fault Off No UPS Connection On • Active Status Meaning Fault of device Off ...

  • GE 1018959 - page 13

    2.5 ADDITIONAL DOCUMENTS The SNMP/Web adapter is provided with a CD-ROM containing the following documentation: • Installation Manual • Operating Manual • SNMP Management Information Base (MIB) • Release notes and other in structions, as applicable Modifications reserv ed Page 13/24 ISG_CNT_SNM_BAS_CRD_1GB_V012.doc Installation Guide SNMP/W ...

  • GE 1018959 - page 14

    3 INSTALLATION NOTE ! Strictly observe the ‘ UPS Safety Rules ’. Read carefully the UPS ‘ Operating Manual & Installation Guide ’ before installing or operating th e equipment. If any problems are encounte red with the installation procedure here described, please contact the nearest Service Centre before proceeding. 3.1 3-PH SNMP/WEB P ...

  • GE 1018959 - page 15

    Modifications reserv ed Page 15/24 ISG_CNT_SNM_BAS_CRD_1GB_V012.doc Installation Guide SNMP/Web Ada pter 3.1.2 Installing the SNMP Card in option slot IMPORTANT: Switch off the UPS, and wait approx. 2 minut es or switch the UPS to the manual bypass. In the latter case, please ensu re that the mains inpu t is reliable during this period. All cables ...

  • GE 1018959 - page 16

    Install procedure for SG Series SGT5000_050-080_UPS_GE_03 Q1 OFF ON Q2 ON OFF 1. Change the front plate with the smaller one delivered with the Kit. 2. Insert the SNMP adapter in the options slot. 3. Fix the front plate of the SNMP adapter to the connectivity box, using the screw include d in the SNMP/Web adapter kit. 3.1.3 Connecting the card Refe ...

  • GE 1018959 - page 17

    • Make all necessary connections (see architecture diagram in section 2.4 ). Contact i /f • Switch on the UPS or go back to normal mode from bypass. 3.3 SP SNMP/WEB PLUG-IN AD APTER (P/N 1019070) • Switch off the UPS, and wait approx. 2 minutes or switch the UPS to the manual bypass. In the latter case, please ensure that the mains input is r ...

  • GE 1018959 - page 18

    • Connect the power to the box (left-most connector in the picture abov e). Make sure that the SNMP/WEB Interface box is powered b y the UPS output! • The UPS / Fail LED will switch OFF once th e connection to the UPS is established. If the LED remains continuously on, chec k the UPS connection and related cabling. 3.5 INTERFACES UTP 10/ 100 ? ...

  • GE 1018959 - page 19

    4 CONFIGURATION 4.1 CONFIGURATION METHODS The SNMP/Web plug-in adapters can be co nfigured using different interfaces. 4.1.1 Configuration via serial connection • Connect the SNMP adapter to a computer using a standard 1:1 serial co mmunication cable. • Run a terminal simulator (e.g. H yperTerminal on a PC running Windows) • Configure the ter ...

  • GE 1018959 - page 20

    NOTE : Although the console interface provides a full set of comman ds, access using the serial connection is only needed for initial configuration when no DHCP server is available, or the IP-address is unknown. The quick network configuration menu pr ovides a simple interface for basic network configuration. For all other settings the us er-friend ...

  • GE 1018959 - page 21

    4.2 NETWORK PARAMETERS The SNMP/Web adapter connects to the ne twork using the foll owing parameters: • IP address identifies the adapter on the network. • Subnet mask defines a range of addresses within the organisation. • Gateway the node used for connection to addresses outside the subnet. The adapter can be configured to obtain these sett ...

  • GE 1018959 - page 22

    5 ACCESS 5.1 WEB INTERFACE After the installation and configuration of the SNMP/Web adapter, th e connection can be tested with a web browser. • Launch the browser • Enter the URL of the SNMP/Web adapter: http://< IP>/ (e.g. http://192.168.24 .14/) • When prompted, enter username and pa ssword (by default, these are set t o ge and ge ) ...

  • GE 1018959 - page 23

    6 CUSTOMER SUPPORT 6.1 FIRST LINE SUPPORT Please contact your local GE distri butor for problems with the ins talla tion of t he product or its use. 6.2 INTERNET On-line support available on requ est (Internet acce ss required). 6.3 WWW SERVER We have a WWW server running at www.gedigitalenergy.com With your favourite web browser yo u can access th ...

  • GE 1018959 - page 24

    7 APPENDIX A SitePro EARTH CONNECTION In order to guarantee correct func tional behaviour, the SNMP/Web plug-in adapter must be connected to protective earth (UPS chassis). On SiteP ro UPSs manufactured before 2003 the square plates (delivered with the 3-ph adapter kit) must be mounted – refer to the pictures below for the installation details. N ...

メーカー GE カテゴリー Network Card

GE 1018959のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1018959の取扱説明書
- GEの製品カード
- パンフレット
- またはGE 1018959の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、GE 1018959の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、GE 1018959の取り付け説明書、サービスマニュアル、簡易説明書、またはGE 1018959のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、GE 1018959の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

GE 1018959デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGE 1018959を使用するのを助ける技術的文書のことです。説明書は通常、全てのGE 1018959ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

GEの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. GE 1018959の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGE 1018959の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。GE 1018959に関してこのドキュメントで見つけることができる全てのヒントの目次
3. GE 1018959デバイスの基本機能を使うにあたってのヒント。 GE 1018959のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。GE 1018959に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGE 1018959のメーカー/サービスへの連絡先に関する情報。

GE 1018959についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGE 1018959の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGE 1018959で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)