Adams MDW-250Lの取扱説明書

20ページ 0.25 mb
ダウンロード

ページに移動 of 20

Summary
  • Adams MDW-250L - page 1

    © Adam Equipm ent Com pany 2012 Adam Equipment MDW – 25 0L DIGIT A L HE ALTH AND FITNESS SC A LE Software EMW-250L-20 080601 ADAM EQUIP MENT CO. L TD. p.n. 4302, Rev. C5, Januar y 2012 ...

  • Adams MDW-250L - page 2

    © Adam Equipm ent Com pany 2012 Page 1 Rev C5, Janu ary 2012 ...

  • Adams MDW-250L - page 3

    © Adam Equipm ent Com pany 2012 Page 2 Rev C5, Janu ary 2012 CONTENTS 1.0 INTRODUCTION .......................................................................................... 4 2.0 TECHNICAL SPECIFI CATIONS .................................................................. 4 3.0 DISPLAY AND KEY D ESCRIPTIONS .................................... ...

  • Adams MDW-250L - page 4

    © Adam Equipm ent Com pany 2012 Page 3 Rev C5, Janu ary 2012 ...

  • Adams MDW-250L - page 5

    © Adam Equipm ent Com pany 2012 Page 4 Rev C5, Janu ary 2012 1.0 INTR ODUCTION • The MDW 250L scale is a Digital Health and Fitness Scale. • It is an accurate electronic device with advanced design and st able performance. • It is designed to measure both the weight and the height of a person. 2.0 TECHNI C A L SPECIFIC A TIONS Maximum capaci ...

  • Adams MDW-250L - page 6

    © Adam Equipm ent Com pany 2012 Page 5 Rev C5, Janu ary 2012 3.0 DISP LA Y A ND K EY DESCRIPTIONS KEYS FUNCTIONS [On / Off /Zero] To turn the scale on or off . To zero the scale if the displa y drifts from zero. [Tare] To tare the scale, if necessary. [Units] To toggle the weighing unit between Kg an d Lb. [Print / Hold] To lock the reading even i ...

  • Adams MDW-250L - page 7

    © Adam Equipm ent Com pany 2012 Page 6 Rev C5, Janu ary 2012 4.0 SE TTING UP THE SC ALE • Take the scale out of the box. • Unwind the load cell cable (number 2 o n the diagram). • Run the cable up through the pillar f rom the base of the scale. • Use the 4 screws (number 3 on the diagram) to mount the pillar t o the indicator. • Connecto ...

  • Adams MDW-250L - page 8

    © Adam Equipm ent Com pany 2012 Page 7 Rev C5, Janu ary 2012 5.0 FUNC TION 5.1 WEIGHING • Place the Scale on an even floor and press the [On/Off] key. • The instrument performs a self-test after which it is ready fo r operation. • Press the [On/Off] key and the machine switches off. • The person to be weighed can step on to the platform on ...

  • Adams MDW-250L - page 9

    © Adam Equipm ent Com pany 2012 Page 8 Rev C5, Janu ary 2012 5.2 MEASURING HEIGH T • W hile meas uring the height, it is necessary to pull up the measuring board at a right angle with the insid e tube. • W hen the tube is pulled out straight, it is sufficient to measure the height fo rm 80-136cm. The numb er can be obtained up on the conjoint ...

  • Adams MDW-250L - page 10

    © Adam Equipm ent Com pany 2012 Page 9 Rev C5, Janu ary 2012 show ‘ 250.0kg ’ or ’ 500.0lb ’ de pending o n which un it you chosen, this is the default calibration weight from t he f actory. Press the [UNIT] ke y t o select the calibration weight unit t hat you want to calibrate in. Press the [ON / OFF] ke y to exit the ca libration m ode ...

  • Adams MDW-250L - page 11

    © Adam Equipm ent Com pany 2012 Page 10 Rev C5, Januar y 2012 7.0 User Parameter s This indicator has 4 parameter set tings that can be selected. 1. W hen the scale is in normal weighing mode, press a nd hold down the [ON / O FF] key and the [UNIT] key for 3 seconds until ‘ SEtUP ’ is sho wn on the display. 2. W hen in the SETUP m ode, press t ...

  • Adams MDW-250L - page 12

    © Adam Equipm ent Com pany 2012 Page 11 Rev C5, Januar y 2012 8.0 RS2 32 Commu nications (Only applied for scale with RS232 interface) The Interface parameters are: Connection details are: 8.1 RS -232 connection between the Scale and the Ho st : Scale -----------------------Cable---------------------------Host (DB9 female)--------(DB9 male)----(DB ...

  • Adams MDW-250L - page 13

    © Adam Equipm ent Com pany 2012 Page 12 Rev C5, Januar y 2012 8.3 When Parameter S.F. in sec tion 7 is set to 1 : Continuous output of the current displayed reading and unit, and no data is received. The output format is as below: <LF>< reading, minus, decimal point, weight unit>GR<CR>< EXT> Or <LF>< reading, minus ...

  • Adams MDW-250L - page 14

    © Adam Equipm ent Com pany 2012 Page 13 Rev C5, Januar y 2012 <p> Polarity character including m inus sign for negative weight and a space character for positive weight W 1- W7 weight data <dp> decimal point U1U2: measure units, kg, lb 8.5.3 Commands and response (1) Command: W <CR> (57h 0dh) Response:  <LF>^^^^^^u1u2< ...

  • Adams MDW-250L - page 15

    © Adam Equipm ent Com pany 2012 Page 14 Rev C5, Januar y 2012 Table1: The status bits def inition: Bit Byte 1 (H 1 ) Byte 2 (H 2 ) B yte 3 (H 3 ) 0=stable 0= not under capacity 0 1= not stable 1= under capacity 0= not at zero point 0= not over capacity 1 1= at zero point 1= over capacity 01=normal work mode 10= hold work mode 00=not define 11= not ...

  • Adams MDW-250L - page 16

    © Adam Equipm ent Com pany 2012 Page 15 Rev C5, Januar y 2012 9.0 Error Messa ges 1. 0 0 0 0 ¯ ¯ ¯ ¯ ¯ Zero point is over the setting range 2. 0 0 0 0 _ _ _ _ _ Zero is below the sett ing range 3. Ad Ad Ad Ad ¯ ¯ ¯¯ ADC is over max. range; 4. Ad Ad Ad Ad _ _ _ _ ADC is b elow min. range; 5. EEP.Er EEP.Er EEP.Er EEP.Er There is an error in ...

  • Adams MDW-250L - page 17

    © Adam Equipm ent Com pany 2012 Page 16 Rev C5, Januar y 2012 ...

  • Adams MDW-250L - page 18

    © Adam Equipm ent Com pany 2012 Page 17 Rev C5, Januar y 2012 ...

  • Adams MDW-250L - page 19

    © Adam Equipm ent Com pany 2012 Page 18 Rev C5, Januar y 2012 Man ufacturer’s Declarati on of Co nformity This product has been m anufactured in accordanc e with the harmonised European s tandards, following the pr ovisions of the below s tated directi ves: Electro Magne tic Compati bility Directi ve 2004/108/ EC Low Voltage D irective 200 6/95/ ...

  • Adams MDW-250L - page 20

    © Adam Equipm ent Com pany 2012 Page 19 Rev C5, Januar y 2012 A D AM EQUIPMENT is an ISO 9001:2000 certi fied global company with more than 35 years experience in the production and sale of electronic w eighing equipment. Adam products are predominan tly designed f or the Laboratory, Educational, Health and Fitness, ret ail and Industrial Segments ...

メーカー Adams カテゴリー Postal Equipment

Adams MDW-250Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MDW-250Lの取扱説明書
- Adamsの製品カード
- パンフレット
- またはAdams MDW-250Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Adams MDW-250Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Adams MDW-250Lの取り付け説明書、サービスマニュアル、簡易説明書、またはAdams MDW-250Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Adams MDW-250Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Adams MDW-250Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAdams MDW-250Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのAdams MDW-250Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Adamsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Adams MDW-250Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAdams MDW-250Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Adams MDW-250Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Adams MDW-250Lデバイスの基本機能を使うにあたってのヒント。 Adams MDW-250Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Adams MDW-250Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAdams MDW-250Lのメーカー/サービスへの連絡先に関する情報。

Adams MDW-250Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAdams MDW-250Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAdams MDW-250Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください