Manual Adams MDW-250L

20 pages 0.25 mb
Download

Go to site of 20

Summary
  • Adams MDW-250L - page 1

    © Adam Equipm ent Com pany 2012 Adam Equipment MDW – 25 0L DIGIT A L HE ALTH AND FITNESS SC A LE Software EMW-250L-20 080601 ADAM EQUIP MENT CO. L TD. p.n. 4302, Rev. C5, Januar y 2012 ...

  • Adams MDW-250L - page 2

    © Adam Equipm ent Com pany 2012 Page 1 Rev C5, Janu ary 2012 ...

  • Adams MDW-250L - page 3

    © Adam Equipm ent Com pany 2012 Page 2 Rev C5, Janu ary 2012 CONTENTS 1.0 INTRODUCTION .......................................................................................... 4 2.0 TECHNICAL SPECIFI CATIONS .................................................................. 4 3.0 DISPLAY AND KEY D ESCRIPTIONS .................................... ...

  • Adams MDW-250L - page 4

    © Adam Equipm ent Com pany 2012 Page 3 Rev C5, Janu ary 2012 ...

  • Adams MDW-250L - page 5

    © Adam Equipm ent Com pany 2012 Page 4 Rev C5, Janu ary 2012 1.0 INTR ODUCTION • The MDW 250L scale is a Digital Health and Fitness Scale. • It is an accurate electronic device with advanced design and st able performance. • It is designed to measure both the weight and the height of a person. 2.0 TECHNI C A L SPECIFIC A TIONS Maximum capaci ...

  • Adams MDW-250L - page 6

    © Adam Equipm ent Com pany 2012 Page 5 Rev C5, Janu ary 2012 3.0 DISP LA Y A ND K EY DESCRIPTIONS KEYS FUNCTIONS [On / Off /Zero] To turn the scale on or off . To zero the scale if the displa y drifts from zero. [Tare] To tare the scale, if necessary. [Units] To toggle the weighing unit between Kg an d Lb. [Print / Hold] To lock the reading even i ...

  • Adams MDW-250L - page 7

    © Adam Equipm ent Com pany 2012 Page 6 Rev C5, Janu ary 2012 4.0 SE TTING UP THE SC ALE • Take the scale out of the box. • Unwind the load cell cable (number 2 o n the diagram). • Run the cable up through the pillar f rom the base of the scale. • Use the 4 screws (number 3 on the diagram) to mount the pillar t o the indicator. • Connecto ...

  • Adams MDW-250L - page 8

    © Adam Equipm ent Com pany 2012 Page 7 Rev C5, Janu ary 2012 5.0 FUNC TION 5.1 WEIGHING • Place the Scale on an even floor and press the [On/Off] key. • The instrument performs a self-test after which it is ready fo r operation. • Press the [On/Off] key and the machine switches off. • The person to be weighed can step on to the platform on ...

  • Adams MDW-250L - page 9

    © Adam Equipm ent Com pany 2012 Page 8 Rev C5, Janu ary 2012 5.2 MEASURING HEIGH T • W hile meas uring the height, it is necessary to pull up the measuring board at a right angle with the insid e tube. • W hen the tube is pulled out straight, it is sufficient to measure the height fo rm 80-136cm. The numb er can be obtained up on the conjoint ...

  • Adams MDW-250L - page 10

    © Adam Equipm ent Com pany 2012 Page 9 Rev C5, Janu ary 2012 show ‘ 250.0kg ’ or ’ 500.0lb ’ de pending o n which un it you chosen, this is the default calibration weight from t he f actory. Press the [UNIT] ke y t o select the calibration weight unit t hat you want to calibrate in. Press the [ON / OFF] ke y to exit the ca libration m ode ...

  • Adams MDW-250L - page 11

    © Adam Equipm ent Com pany 2012 Page 10 Rev C5, Januar y 2012 7.0 User Parameter s This indicator has 4 parameter set tings that can be selected. 1. W hen the scale is in normal weighing mode, press a nd hold down the [ON / O FF] key and the [UNIT] key for 3 seconds until ‘ SEtUP ’ is sho wn on the display. 2. W hen in the SETUP m ode, press t ...

  • Adams MDW-250L - page 12

    © Adam Equipm ent Com pany 2012 Page 11 Rev C5, Januar y 2012 8.0 RS2 32 Commu nications (Only applied for scale with RS232 interface) The Interface parameters are: Connection details are: 8.1 RS -232 connection between the Scale and the Ho st : Scale -----------------------Cable---------------------------Host (DB9 female)--------(DB9 male)----(DB ...

  • Adams MDW-250L - page 13

    © Adam Equipm ent Com pany 2012 Page 12 Rev C5, Januar y 2012 8.3 When Parameter S.F. in sec tion 7 is set to 1 : Continuous output of the current displayed reading and unit, and no data is received. The output format is as below: <LF>< reading, minus, decimal point, weight unit>GR<CR>< EXT> Or <LF>< reading, minus ...

  • Adams MDW-250L - page 14

    © Adam Equipm ent Com pany 2012 Page 13 Rev C5, Januar y 2012 <p> Polarity character including m inus sign for negative weight and a space character for positive weight W 1- W7 weight data <dp> decimal point U1U2: measure units, kg, lb 8.5.3 Commands and response (1) Command: W <CR> (57h 0dh) Response:  <LF>^^^^^^u1u2< ...

  • Adams MDW-250L - page 15

    © Adam Equipm ent Com pany 2012 Page 14 Rev C5, Januar y 2012 Table1: The status bits def inition: Bit Byte 1 (H 1 ) Byte 2 (H 2 ) B yte 3 (H 3 ) 0=stable 0= not under capacity 0 1= not stable 1= under capacity 0= not at zero point 0= not over capacity 1 1= at zero point 1= over capacity 01=normal work mode 10= hold work mode 00=not define 11= not ...

  • Adams MDW-250L - page 16

    © Adam Equipm ent Com pany 2012 Page 15 Rev C5, Januar y 2012 9.0 Error Messa ges 1. 0 0 0 0 ¯ ¯ ¯ ¯ ¯ Zero point is over the setting range 2. 0 0 0 0 _ _ _ _ _ Zero is below the sett ing range 3. Ad Ad Ad Ad ¯ ¯ ¯¯ ADC is over max. range; 4. Ad Ad Ad Ad _ _ _ _ ADC is b elow min. range; 5. EEP.Er EEP.Er EEP.Er EEP.Er There is an error in ...

  • Adams MDW-250L - page 17

    © Adam Equipm ent Com pany 2012 Page 16 Rev C5, Januar y 2012 ...

  • Adams MDW-250L - page 18

    © Adam Equipm ent Com pany 2012 Page 17 Rev C5, Januar y 2012 ...

  • Adams MDW-250L - page 19

    © Adam Equipm ent Com pany 2012 Page 18 Rev C5, Januar y 2012 Man ufacturer’s Declarati on of Co nformity This product has been m anufactured in accordanc e with the harmonised European s tandards, following the pr ovisions of the below s tated directi ves: Electro Magne tic Compati bility Directi ve 2004/108/ EC Low Voltage D irective 200 6/95/ ...

  • Adams MDW-250L - page 20

    © Adam Equipm ent Com pany 2012 Page 19 Rev C5, Januar y 2012 A D AM EQUIPMENT is an ISO 9001:2000 certi fied global company with more than 35 years experience in the production and sale of electronic w eighing equipment. Adam products are predominan tly designed f or the Laboratory, Educational, Health and Fitness, ret ail and Industrial Segments ...

Manufacturer Adams Category Postal Equipment

Documents that we receive from a manufacturer of a Adams MDW-250L can be divided into several groups. They are, among others:
- Adams technical drawings
- MDW-250L manuals
- Adams product data sheets
- information booklets
- or energy labels Adams MDW-250L
All of them are important, but the most important information from the point of view of use of the device are in the user manual Adams MDW-250L.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Adams MDW-250L, service manual, brief instructions and user manuals Adams MDW-250L. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Adams MDW-250L.

Similar manuals

A complete manual for the device Adams MDW-250L, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Adams MDW-250L by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Adams MDW-250L.

A complete Adams manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Adams MDW-250L - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Adams MDW-250L, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Adams MDW-250L, that we can find in the current document
3. Tips how to use the basic functions of the device Adams MDW-250L - which should help us in our first steps of using Adams MDW-250L
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Adams MDW-250L
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Adams MDW-250L in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Adams MDW-250L?

Use the form below

If you did not solve your problem by using a manual Adams MDW-250L, ask a question using the form below. If a user had a similar problem with Adams MDW-250L it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)