Oregon Scientific TP391の取扱説明書

18ページ 1.45 mb
ダウンロード

ページに移動 of 18

Summary
  • Oregon Scientific TP391 - page 1

    Pair of PMR446 T wo-W ay Personal Radios Model: TP391 USER MANUAL MANUALE D’USO MANUEL DE L ’UTILISA TEUR BEDIENUNGSANLEITUNG MANUAL DE USUARIO MANUAL DO USUÁRIO HANDLEIDING BRUKSANVISNING P/N:086L004722-016 REV.1 PAGE: 1/152 ...

  • Oregon Scientific TP391 - page 2

    EN C O N T E N T S Introduction ............................................................................................. 1 Key Features ........................................................................................... 1 Front view............................................................................................... 1 Back vi ...

  • Oregon Scientific TP391 - page 3

    1 EN INTRODUCTION Thank you for selecting the Oregon Scientic™ TP391as your product of choi ce. This prod uct is a port able, ea sy-to -use two -way rad io trans ceive r that you ca n use to con tact your fami ly and friend s at shopp ing mal ls, amu seme nt parks, sports events, beaches, forests and so on. Y ou can also use it as a vital comm ...

  • Oregon Scientific TP391 - page 4

    2 EN NO. DESCRIPTION FUNCTION 0 Antenna Receives and transmits signals 1 LED indicator Lights up red when transmitting a signal 2 Auto scans for available channel / Monitors current channel for activity 3 Scrolls through menu options / Locks and unlocks the keypad 4 Speaker Generates audible sound 5 Connection Slot pins into a desktop charger docki ...

  • Oregon Scientific TP391 - page 5

    3 EN BACK VIEW NO. DESCRIPTION FUNCTION 1 Battery door Remove to access battery compartment 2 Battery Uses lithium 3.7V -720mAh rechargeable compartment battery 3 Sends call tone to other users of the same frequency P/N:086L004722-016 REV.1 PAGE: 5/152 ...

  • Oregon Scientific TP391 - page 6

    4 EN L C D D I S P L A Y S Y M B O LS SYMBOL FUNCTION Channel number: Select between 8 channels CTCSS code: Adjust to minimize interference problems Dual W atch: Monitor 2 channels simultaneously Battery indicator: Provides battery status during operation Call tone: Page another user Keypad lock: Locks keypad to prevent accidental button activation ...

  • Oregon Scientific TP391 - page 7

    5 EN SAFETY AND CARE INSTRUCTIONS SAFETY PRECAUTIONS Please observe the following safety precautions when setting up and using this product. * LCD panel – The LCD panel is made of glass, and may break if the unit is dropped or impacted. * Heat sources – Keep the product away from heat sources such as radiators, stoves, heaters, and other heat-g ...

  • Oregon Scientific TP391 - page 8

    6 EN * Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary . * No naked ames, such as lighted candles, should be placed near the apparatus. * T o reduce the risk of electric shock, do not expose this application to rain or moisture. GETTING ST ARTED P O WE R T o insert t ...

  • Oregon Scientific TP391 - page 9

    7 EN T o charge the battery using the AC adapter: Charge the batte ry for 12 hours on the rst charge . After that, it should take 3 or less hours to char ge. The LCD backlig ht will be turned on when charging. The LED indicator will be turned on when battery is full. NOTE: 1. T o maintain the battery life of your two-way transceiver it is recomm ...

  • Oregon Scientific TP391 - page 10

    8 EN V O LU M E T o change the volume level: Use or to increase or decrease volume. RESET T o reset the unit: Remove the batteries for two minutes and insert them again. T ALK TO ANOTHER TRANSCEIVER For best transmission speak about 5 cm away from the radio and leave a short pause before speaking once you have pressed . T o talk to another transcei ...

  • Oregon Scientific TP391 - page 11

    9 EN K E YPA D L O C K T o avoid acciden tally changing the channel and the unit’s prefer red settings, you can lock the keypad. T o lock or unlock the keypad: Press and hold for 1.5 seconds. appears when the keypad is locked. NOTE: While the keypad is on you can still use the and keys. MENU OPTIONS T o access the Menu Options and change settings ...

  • Oregon Scientific TP391 - page 12

    10 EN 3. Press to conrm and move to the next setting or press to conrm the changes and exit the Menu Options. Settings will automatically be conrmed after 5 seconds if no key is pressed. SELECT A CHANNEL OR CTCSS The transmitter and receiver must be on the same channel using the same CTCSS code in order for you to communicate with another ...

  • Oregon Scientific TP391 - page 13

    1 1 EN C A LL TO N E T o alert other radios set to the same channel as you that you want to communicate with them, you can transmit a call tone to pre-warn them. T o change the call tone: 1. Press 3 times un til the number starts ashing. 2. Press a nd hold to change the tone. 3. Pre ss to conrm and exit the menu. Or , press to co nrm and g ...

  • Oregon Scientific TP391 - page 14

    12 EN T o change the VOX level: 1. Pre ss 4 tim es until the number starts ashing. 2. Press and hold or to change the VOX level. 3. Press to conrm and exit the menu. Or , press to conrm and go to the next Menu Option. LCD SYMBOL DESCRIPTION 0 VOX disabled 3 Low sensitivity – only audibly loud voices are transmitted (useful for noisy envi ...

  • Oregon Scientific TP391 - page 15

    13 EN DUAL W A TCH (DW) The Dual Watch feature allows you to monitor more than one channel simultaneously . T o set Dual Watch: 1. Press 6 times until “DW” appears and the channel number starts ashing. 2. Press and hold or to select a watch channel (1-8). 3. Pres s to c onrm and exit the menu. Or , press to conrm an d go to the next Me ...

  • Oregon Scientific TP391 - page 16

    14 EN T o stop auto-scan: Press . The unit will revert back to the original channel that was set prio r to scanning. NOTE: If you activate a scan while your code is set to 0, the radio will check for any activity on each channel, regardless of the code used on that channel. If you activat e a scan while the code is between 1 and 38, the radio will ...

  • Oregon Scientific TP391 - page 17

    15 EN SPECIFICA TIONS Operation frequency 446.00625 to 446.09375 MHz Channels 8 CTCSS Codes 38 standard codes Modulation type FM Microphone Internal / external condenser type Power supply 3.7V 720mAH Li-ion battery Sensitivity <= -1 19 dBm Noise squelch Auto VOX levels 3 Call tones 10 Audio output power 125mW Audio distortion < 5% RX signal t ...

  • Oregon Scientific TP391 - page 18

    16 EN ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientic.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and tness gear; weather stations; and digital and conference phones. The websi te also inclu des contac t ...

メーカー Oregon Scientific カテゴリー Two-Way Radio

Oregon Scientific TP391のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TP391の取扱説明書
- Oregon Scientificの製品カード
- パンフレット
- またはOregon Scientific TP391の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Oregon Scientific TP391の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Oregon Scientific TP391の取り付け説明書、サービスマニュアル、簡易説明書、またはOregon Scientific TP391のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Oregon Scientific TP391の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Oregon Scientific TP391デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOregon Scientific TP391を使用するのを助ける技術的文書のことです。説明書は通常、全てのOregon Scientific TP391ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Oregon Scientificの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Oregon Scientific TP391の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOregon Scientific TP391の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Oregon Scientific TP391に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Oregon Scientific TP391デバイスの基本機能を使うにあたってのヒント。 Oregon Scientific TP391のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Oregon Scientific TP391に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOregon Scientific TP391のメーカー/サービスへの連絡先に関する情報。

Oregon Scientific TP391についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOregon Scientific TP391の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOregon Scientific TP391で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)