CDA EVM9の取扱説明書

12ページ 1.15 mb
ダウンロード

ページに移動 of 12

Summary
  • CDA EVM9 - page 1

    E V M9 Extr act or s Manual for Inst allation, Use and Maintenanc e Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style ...

  • CDA EVM9 - page 2

    Important The manufacturer cannot be held r esponsible for injuries or losses caused by inc orrect use or inst allation of this product. Please note that the manufactur er reserves the right t o invalidate the guar antee supplied with this pr oduct following incorr ect installation or misuse of the appliance or use in a commer cial envir onment. Th ...

  • CDA EVM9 - page 3

    2 Using your Extr act or For best perf ormance, you should switc h on the extract or 1 5 minutes befor e starting to cook and lea ve it to run f or appro ximately 1 5 minutes after the end of cooking. Contr ol Panel A - Light key B - Decrease speed k ey C - Display D - Increase speed k ey E - Timer key T o switch the extr act or light on and off ? ...

  • CDA EVM9 - page 4

    3 Car e and Maintenanc e IMPOR T ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACT OR WITHOUT FIRST SWIT CHING OFF THE ELE CTRICITY SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasiv e cleaner (including Cif) will scratc h the surface and could er ase the contr ol panel markings. Y ou can clean your extractor eff ecti ...

  • CDA EVM9 - page 5

    4 Fig. 5 Changing the Light IMPOR T ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACT OR WITHOUT FIRST SWIT CHING OFF THE ELECTRICITY SUPPL Y . DO NO T CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HO T . ALL OW IT T O COOL BEFORE REM OVING IT . Carefully prise the bulb fr om the extract or using a small, flat-bladed ...

  • CDA EVM9 - page 6

    5 DOUBLE POLE SWIT CHED FUSED SPUR OUTLET USE A 3 AMP FUSE Mains Electricity Connection THIS APPLIANCE MUST BE C ONNECTED T O THE MAINS SUPPL Y BY A C OMPE TENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSED SPUR OUTLET AND PR O TECTED B Y A 3A FUSE. W e r ecommend that the appliance is c onnected by a qualified electrician, who is a ...

  • CDA EVM9 - page 7

    6 Installation Y our extractor can be used to filter and r ecycle the air within your kitc hen, or to extract the air outside. When extr acting air to the outside, the unit can be vented as shown in the diagr am below . Note that we recommend the use of ducting with a diameter of 1 50mm. Ducting with diameters of 1 00mm or 1 20mm may be used, but ...

  • CDA EVM9 - page 8

    7 Fitting your extr actor to the w all Next, remov e the top cover by loosening the scr ews (b), closing the front panel and then lifting the c over off. The extractor is mount ed using four scr ews. Ensur e that the wall fixings and scr ews are suit able for the wall mat erial. Mark the positions of the four holes on the wall, ac cording to (fig ...

  • CDA EVM9 - page 9

    8 Fitting your extr actor to the w all Insert the 4 wall plugs in to the holes and fix 2 scr ews in the top holes so that they ar e protruding fr om the wall by appro x 5mm (fig 1 2). Next, lift the hood onto the 2 scr ews as shown in (fig1 2). Secure the t op two scr ews and fix the hood into position using screw s inserted into the 2 lower ho ...

  • CDA EVM9 - page 10

    9 Using the extr act or as an extr action device W ork out the r equir ed height of the optional chimney for your ceiling and mount the c himney fixing brack et as shown in the (fig 1 6), then secur e the chimney as shown in (fig 1 7a). Finally , locate the chimney to the body of the extractor as shown in (fig 1 8). Fig. 1 6 Fig. 1 8 Fig. 1 7 2 ...

  • CDA EVM9 - page 11

    10 ...

  • CDA EVM9 - page 12

    Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style T o cont act our Customer Car e Department, or f or Service, please contact us on the det ails below . ...

メーカー CDA カテゴリー Ventilation Hood

CDA EVM9のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EVM9の取扱説明書
- CDAの製品カード
- パンフレット
- またはCDA EVM9の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、CDA EVM9の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、CDA EVM9の取り付け説明書、サービスマニュアル、簡易説明書、またはCDA EVM9のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、CDA EVM9の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

CDA EVM9デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCDA EVM9を使用するのを助ける技術的文書のことです。説明書は通常、全てのCDA EVM9ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

CDAの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. CDA EVM9の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCDA EVM9の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。CDA EVM9に関してこのドキュメントで見つけることができる全てのヒントの目次
3. CDA EVM9デバイスの基本機能を使うにあたってのヒント。 CDA EVM9のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。CDA EVM9に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCDA EVM9のメーカー/サービスへの連絡先に関する情報。

CDA EVM9についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCDA EVM9の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCDA EVM9で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)