    19 - 2021 Rev E , 0 6/05/ 07 1 V - Flex ® High Output UV Device INSTALLER/OWNER’S GU IDE Specifications subject to change without notice. ©Altru - V and V - Flex are brands owned by UVDI. Copyright © 2003 by UltraViolet Devices, Inc. All rights reserved. ...

  • UltraViolet Devices V-Flex - page 2

    19 - 2021 Rev E , 0 6/05/ 07 2 TABLE OF CONTENTS SPECIFICATIONS ........................................................................................................... 3 Electrical Ratings ....................................................................................................... 3 Approvals ......................................... ...

  • UltraViolet Devices V-Flex - page 3

    19 - 2021 Rev E , 0 6/05/ 07 3 SPECIFICATIONS Electrical Ratings Power Ratings Note: The V - Flex is a universa l input circuit capable of operation at 120 Vac or 240 Vac and 50Hz or 60Hz. The unit is designed to be hardwired to an appropriate electrical service in accordance with NEC. Temperature Ratings Ambient Temperature Range: 40°F to 135°F ...

  • UltraViolet Devices V-Flex - page 4

    19 - 2021 Rev E , 0 6/05/ 07 4 APPLICATION When installed in forced air heating and cooling systems, the V - Flex kills airborne and surface microorganism contaminants. It is designed to be mounted in - duct for airborne, “ on - the - fly” applications as well as surface irradiation applications. The design allows for many different levels of U ...

  • UltraViolet Devices V-Flex - page 5

    19 - 2021 Rev E , 0 6/05/ 07 5 Never look at the lamps while illuminated. Only view illumination by way of view port accessory. To prevent exposure to ultraviolet light, disconnect power to the V - Flex before servicing any part of the HVAC system. MOUNTING LOCATION CAUTION Equipment Damage Hazard Ultraviolet light can cause color shift or structur ...

  • UltraViolet Devices V-Flex - page 6

    19 - 2021 Rev E , 0 6/05/ 07 6 2. Determine the number and configuration of Lamp Modules and Power Junction Modules. Note: the maximum number of Lamp Modules (19 - 1000) to be installed per Power Junction Module (19 - 1020) is 24. 3. Mark the location of the lower mounting bracket on the lower mounting surface of the installation area. 4. Measure o ...

  • UltraViolet Devices V-Flex - page 7

    19 - 2021 Rev E , 0 6/05/ 07 7 8. Select one side of the Main Support to start assembly of lamp modules. Begin assembly of the Lamp Modules attachments first (see Figure 3b). Begin by installing the Lamp Module furthest from the Power Junction Module location. 9. Thread the t hree wires from the last Lamp Module installed to the main extrusion thro ...

  • UltraViolet Devices V-Flex - page 8

    19 - 2021 Rev E , 0 6/05/ 07 8 20. After installation of the last Lamp Module on the side opposite of the Power Junction Module, route the power wi res from the last Lamp Module installed through the feed through hole connecting the wire raceway from either side. Do not install lamps at this stage. (see Figure 3c for example of completely wired sys ...

  • UltraViolet Devices V-Flex - page 9

    19 - 2021 Rev E , 0 6/05/ 07 9 IMPORTANT It is a requirement to incorporate the w ire raceway covering to all exposed portions of the wire raceway on the mounting sides of the Main Support where modules have been mounted. 27. Identify, measure and record all spaces on the Main Support between Lamp Modules and the Power Junction Module (s ee Figure ...

  • UltraViolet Devices V-Flex - page 10

    19 - 2021 Rev E , 0 6/05/ 07 10 ELECTRICAL CONNECTION OF THE SYSTEM WARNING Personal Serious Injury Hazard Pow er supply can cause severe electrical shock. Disconnect power supply before installation. All wiring should be in accordance with NEC. 1. Bring power to the Power Junction Module and use appropriate knock - out on the Power Junction Module ...

  • UltraViolet Devices V-Flex - page 11

    19 - 2021 Rev E , 0 6/05/ 07 11 ...

  • UltraViolet Devices V-Flex - page 12

    19 - 2021 Rev E , 0 6/05/ 07 12 2. Insert the black V - Flex Clip into the module so that is holding the lamp in place and the clip is secured onto the metal module . Make sure the cli p is slid over the lamp module as shown below : 3. Push the lamp in till it snaps into place. V erify that lamp is retained. 4. Lamp should not have any slack to mov ...

  • UltraViolet Devices V-Flex - page 13

    19 - 2021 Rev E , 0 6/05/ 07 13 WARNING UV Light Hazard Harmful to bare skin and eyes. Can cause tempo rary or permanent loss of vision. Never look at the lamps while illuminated. Only view illumination by way of view port accessory. To prevent exposure to ultraviolet light, disconnect power to the V - Flex before servicing any part of the HVAC sys ...

  • UltraViolet Devices V-Flex - page 14

    19 - 2021 Rev E , 0 6/05/ 07 14 CAUTION UV Lamp Burn Hazard Harmful to bare skin. Can cause severe burns. Disconnect power 15 minutes before removing the ultraviolet lamp. WARNING UV Light Haza rd Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamps while illuminated. Only view illumination by way ...

  • UltraViolet Devices V-Flex - page 15

    19 - 2021 Rev E , 0 6/05/ 07 15 3. Allow the lamp to cool for at least 15 minutes. 4. Depress lamp release button and remove lamp. Be careful not to stri ke or hit the lamp glass with the enclosure edges. 5. Insert new lamp into the Lamp Module. Depress lamp release button and insert lamp. Let go of the lamp release button and verify that lamp is r ...

  • UltraViolet Devices V-Flex - page 16

    19 - 2021 Rev E , 0 6/05/ 07 16 EQUIPMENT W ARRANTY UltraViolet Devices, Inc. (UVDI) , warrants to original Buyer for one year from the date of original installation, or eighteen (18) months from date of shipment, whichever comes first, that its goods are free from defect in material and workmanship under normal use and service. UVDI ’s obligatio ...

メーカー UltraViolet Devices カテゴリー Network Card

UltraViolet Devices V-Flexのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- V-Flexの取扱説明書
- UltraViolet Devicesの製品カード
- パンフレット
- またはUltraViolet Devices V-Flexの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、UltraViolet Devices V-Flexの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、UltraViolet Devices V-Flexの取り付け説明書、サービスマニュアル、簡易説明書、またはUltraViolet Devices V-Flexのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、UltraViolet Devices V-Flexの製品を使用するにあたって最も人気のある説明書を閲覧できます。

UltraViolet Devices V-Flexデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUltraViolet Devices V-Flexを使用するのを助ける技術的文書のことです。説明書は通常、全てのUltraViolet Devices V-Flexユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

UltraViolet Devicesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. UltraViolet Devices V-Flexの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUltraViolet Devices V-Flexの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。UltraViolet Devices V-Flexに関してこのドキュメントで見つけることができる全てのヒントの目次
3. UltraViolet Devices V-Flexデバイスの基本機能を使うにあたってのヒント。 UltraViolet Devices V-Flexのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。UltraViolet Devices V-Flexに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUltraViolet Devices V-Flexのメーカー/サービスへの連絡先に関する情報。

UltraViolet Devices V-Flexについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUltraViolet Devices V-Flexの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUltraViolet Devices V-Flexで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)