Summary
  • AquaStar 125FX NG - page 1

    WARNING : Improper installation, adjustment , alt eration , service or maintenance can c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or t he gas supplier. Upon completion of the installation, these instructions should be handed to the user of the applia ...

  • AquaStar 125FX NG - page 2

    2 6 720 606 601 AquaSt ar 1 25FX LP and 1 25FX NG Specific ations W ater Connection 1 /2” Thread fitting N P T H x W x D 29 3/ 4” x 1 8 1 /4” x 8 3/4" V ent 4” Gas C onnection 1 /2” N PT thread Min. W ater Pressure 1 8 Psi Max. W ater Pressure 1 50 Psi Shipping W eight 50.6 LB Net W eight 44 LB 2.0 G PM at 90 ° rise 4.0 G PM at 45 ? ...

  • AquaStar 125FX NG - page 3

    3 6 720 606 601 M I N I M U M I N S T ALLA TI ON C LE AR A N C E S F R OM C O M B USTI B LE AN D N ON C OM B U S TI B LE MA TE R IALS F OR AL C O VE OR C L O SET I N S T ALLA TI ON S FR ONT VI EW SI D E VI EW A QUAST AR MO DE L 1 25FX * On a combustible wall surface the unit should be mounted away from the wall to provide adequate clearance of the ...

  • AquaStar 125FX NG - page 4

    4 6 720 606 601 G EN E RAL R U LES T O FOLL OW FOR SAFE O PE R A TI ON 1. Y ou should follow these instructions when you inst all your heater . In the United St ates: The installation must conform with local codes or , in the absence of local codes, the National Fuel Gas Code AN SI Z223. 1 / N FP A 54. In Canada: The Installation should conform wit ...

  • AquaStar 125FX NG - page 5

    5 6 720 606 601 COMBUSTION AIR REQUIREMENTS The AquaStar water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components. This Installation Manual specifies the vent length requirements and the amount ...

  • AquaStar 125FX NG - page 6

    6 6 720 606 601 Fig . 3 - Inc andescent Part icle T ray Illust ration The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 3. SCREWS INCANDESCENT P ARTICLE TRA Y Fig. 2 - Mounting the Heater W ...

  • AquaStar 125FX NG - page 7

    7 6 720 606 601 VENTING WARNING: Do not reduce the vent pipe size and do not common vent with any other vented appliance or stove. This appliance must be vented horizontally to the outside with a sealed 4” single wall vent pipe. The appliance’s flue gasses are under positive pressure and must travel through a single wall 4” pipe that is seale ...

  • AquaStar 125FX NG - page 8

    8 6 720 606 601 Fig 4 : Some V ent ing Guide Suggestions An approved side wall vent terminal must be used when the water heater is vented through a side wall. Locate in accordance with AN SI Z223. 1 and local applicable codes . See Fig 5 for restrictions in location of vent terminal in relation to opening doors and windows, grade, and forced air in ...

  • AquaStar 125FX NG - page 9

    9 6 720 606 601 Fig 5: Side wall exit locations for mechanical draft vent terminals SOFFIT VENT HOOD 7’ MINIMUM ABOVE PUBLIC WALKWA Y ONE FOOT ABOVE GRADE 3’ ABOVE ANY FORCED AIR INLET WITHIN 10’ 4’ MIN 1’ MIN 4’ MIN 4’ MIN 4’ MIN 1’ MIN VENT HOOD MUST BE MOUNTED FOUR FEET A WA Y FROM DOORS AND WINDOWS VENT HOOD MUST BE MOUNTED FO ...

  • AquaStar 125FX NG - page 10

    10 6 720 606 601 Fig. 6 - Appliance pressure regulator (with directional arrow on reverse side pointing up) GAS LINE SIZING The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure (as indicated on the rating plate and in the manual for altitude up to 2000 feet (660 meters) above sea level. On appliances being ...

  • AquaStar 125FX NG - page 11

    11 6 720 606 601 GAS PIPING, CONNECTIONS Before connecting the gas supply, c heck the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected. In the United St ates: T he installation must conform with local codes or, in the absence of local codes, the National Fuel Gas C ...

  • AquaStar 125FX NG - page 12

    12 6 720 606 601 Fig.7 - Water valve and water connectors, top view W A TE R CONN EC TIO N S Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater , the cold water inlet will be on the right and the hot water outlet on the left.. Although water piping throughout the build ...

  • AquaStar 125FX NG - page 13

    13 6 720 606 601 ELECTRICAL CONNECTIONS WARNING: For safety reasons, disconnect the power supply to the heater before any service or testing is performed. WARNING: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code , N FP A 70. In Canada , all electrical wiring to the heater should b ...

  • AquaStar 125FX NG - page 14

    14 6 720 606 601 O PERA T I N G INST R UC T ION S Before operating the heater , make sure that the system is filled with water. Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water faucet after the water ...

  • AquaStar 125FX NG - page 15

    15 6 720 606 601 Fig. 1 2 - Charact eristic Pilot Flame Flame sensor Piezo Electrode W at e r V alve ( Part # 8 7 07 002802): The water valve on this heater should be serviced periodically. Lubricate component #36 on page 20 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings fresh and pushrod sliding smooth ...

  • AquaStar 125FX NG - page 16

    16 6 720 606 601 3. W ater flow is not sufficient to act ivate heater. W ater flow rate at faucet is below minimum flow needed to activate heater . W hen temperature adjustment knob is turned all the way clockwise, the AquaStar model 1 25FX requires 1 /2 gallon per minute flow to activate the heater . As a reference, this is a flow which would fill ...

  • AquaStar 125FX NG - page 17

    17 6 720 606 601 Mineral deposits can eventually (3-5 years in hard water areas) corrode the water valve parts to a point where they will need replacing. Any sign of moisture at the bleed hole is a sign that the water valve needs to be replaced immediat ely . 1 0. Poor circuit connect ions at t he EC O ( overheat sensor ) or the flue gas safety dev ...

  • AquaStar 125FX NG - page 18

    18 6 720 606 601 WA TE R IS T OO H O T 1 . T emperature S election too high T urn the temperature adjustment knob counter-cloc kwise (to the left) to lower the maximum water temperature. Note: This will increase the activation flow rate. 2 . Inlet water temperature is very warm (60°-75°F) Reduce inlet gas supply to lower the heaters degree rise. ...

  • AquaStar 125FX NG - page 19

    19 6 720 606 601 Fig. 1 5 - Diagram of AquaStar 1 25FX 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. electric control box 8. Power cord 9. on/off switch 1 0. T emperature adjustment selector 1 1 . Microswitch 1 2. Gas inlet gas pressure test nipple 1 3. Exhaus ...

  • AquaStar 125FX NG - page 20

    20 6 720 606 601 Fig. 1 6 - I NTE RI OR CO MP ON E NTS DIA G RAM AN D P ARTS LIST ...

  • AquaStar 125FX NG - page 21

    21 6 720 606 601 Fig . 1 6 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25FX 1 Cover 8 705 421 775 2T e m p era tur e ad j ustment kno b 8 702 000 111 3T e m p era tur e ad j ustment co l lar 8 700 403 008 4 Dra ft diverter 8 705 505 451 5 He at ex chan g er 8 705 406 235 6 Overheat se n sor (ECO) 8 707 206 040 7 Main burner 8 708 120 298 N G 7 M ...

  • AquaStar 125FX NG - page 22

    22 6 720 606 601 Fig . 1 7 - Flow chart of Aquastar 1 25 F X ...

  • AquaStar 125FX NG - page 23

    23 6 720 606 601 L I M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( B OSC H ) through Controlled Energy C orp. C ontrolled Energy C orp. (C EC ) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable per ...

  • AquaStar 125FX NG - page 24

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park W ait sfield, V ermont 05673 Phone 800-642-31 1 1 Fax (802) 496-6924 ww w .controlledenergy .com/tech techsupport@controlledenergy .com VULCANO T ermodomésticos S.A. Estrada de Cacia 3801 - 856 Aveiro - PORTUGAL 5 1 e g a p e e s E L B A T E C N ...

メーカー AquaStar カテゴリー Water Heater

AquaStar 125FX NGのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 125FX NGの取扱説明書
- AquaStarの製品カード
- パンフレット
- またはAquaStar 125FX NGの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、AquaStar 125FX NGの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、AquaStar 125FX NGの取り付け説明書、サービスマニュアル、簡易説明書、またはAquaStar 125FX NGのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、AquaStar 125FX NGの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

AquaStar 125FX NGデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAquaStar 125FX NGを使用するのを助ける技術的文書のことです。説明書は通常、全てのAquaStar 125FX NGユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

AquaStarの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. AquaStar 125FX NGの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAquaStar 125FX NGの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。AquaStar 125FX NGに関してこのドキュメントで見つけることができる全てのヒントの目次
3. AquaStar 125FX NGデバイスの基本機能を使うにあたってのヒント。 AquaStar 125FX NGのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。AquaStar 125FX NGに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き