    PN: 34000281 R1 SNMP-NET UPS SNMP Card (Web-Based monitoring SNMP Card) User ’ s Manual ...

  • Minute Man SNMP-NET - page 2

    SNMP-NET 2 T able of Content s Chapter 1 In troduction .................................................................................................... 3 Features ....................................................................................................................... ........3 System App licatio n ................................ ...

  • Minute Man SNMP-NET - page 3

    SNMP-NET 3 Chapter 1 Introduction Features • Network connection through RJ45 connector Allows connection of the UPS directly to t he Ethernet network through a RJ45 connector without using RS232 ports on the computer and without loading any i ndividual UPS management software on the network server. • Network UPS management Allows remote managem ...

  • Minute Man SNMP-NET - page 4

    SNMP-NET 4 Figure 1-1 System Application Diagram Figure 1-2 SNMP-NET Card UPS SNM P- NET SNMP Card NMS St a ti on or We b B r o w s e r Shutdown S/W Shutdown S/W Shutdown S/W Operati ng Syst em 1 Pow er Line Ethernet Operati ng Syst em 2 Op erating Syst em N. Ethernet Connection Reset Button Console / ENV Connection Di p Switches ...

  • Minute Man SNMP-NET - page 5

    SNMP-NET 5 Chapter 2 Installation Note: The SNMP-NET cards are designed to be Ho t Swappable, but there is a remote chance that when Hot-Swapping the SNMP-NET card that the UPS will shut down. MINUTEMAN recommends following steps 1 through 8 when inst al ling the SNMP-NET card , but to hot-swap, skip to step number 3 and omit steps 6, 7. 1. T urn o ...

  • Minute Man SNMP-NET - page 6

    SNMP-NET 6 Configuring the SNMP-NET by EzSetting 1. Prepare a workst ation (Microsoft Windows 9x, Me, NT4.0, 2000, 2003, XP or later). 2. Make sure both the DIP-s witches of SNMP-NET are set to OFF position (default: normal mode) to enable network transmission. 3. Make sure the workstation and SNMP-NET device are in the same LAN. 4. Put the CD (pro ...

  • Minute Man SNMP-NET - page 7

    SNMP-NET 7 8. Click on the Configuration button and setup t he essential network parameters. (See 2-3) Figure 2-3 Configure the system p arameters. Configuring the SNMP-NET through the COM Port 1. Prepare a workst ation (Microsoft Windows 9x, Me, NT4.0, 2000, 2003, XP or later). 2. Use the RJ45 to DB9 serial cable (provi ded) to connect between the ...

  • Minute Man SNMP-NET - page 8

    SNMP-NET 8 Configuring the SNMP-NET through Telnet 1. Connect the SNMP-NET SNMP card to the network. 2. Prepare a workst ation (Microsoft Window , Ma x OSX or Linux), which is connected to the same LAN. 3. Set both of the DIP-switches of the SNMP-NET to OFF position (normal mode). 4. From the Windows workstatio n open a DOS Prompt and type “telne ...

  • Minute Man SNMP-NET - page 9

    SNMP-NET 9 User Manager +========================+ User Manager +========================+ A d m i n i s t r a t o r [1]. Account: admin [2]. Password: ******** [3]. Limitation: Only in This LAN Device Manager [4]. Account: device [5]. Password: ******** [6]. Limitation: Only in This LAN Read Only User [7]. Account: user [8]. Password: ******** [9] ...

  • Minute Man SNMP-NET - page 10

    SNMP-NET 10 No. Function Description Default 1. IP Address The SNMP-NET IP address. 192.168.001.100 2. Subnet Mask The sub-net mask setting. 255.255.255.000 3. Gateway IP The network default gateway . 192.168.001.254 4. DNS IP Domain Name Server IP address 192.168.001.001 5. BOOTP/DHCP Client Enable/Dis able BOOTP/DHCP protocol Enable 6. HTTP Serve ...

  • Minute Man SNMP-NET - page 11

    SNMP-NET 11 SNMP Trap If you want to use a PC and perform the SNMP m anager ‘trap’ function in order to manage the UPS through SNMP-NET, the IP address of the PC must be added to the SNMP Trap list. The Event Level field is used to decide what kind of power events should be sent to the target address. There are 3 levels of power events: In form ...

  • Minute Man SNMP-NET - page 12

    SNMP-NET 12 Wake On LAN SNMP-NET supports the packet to wakeup workstations in 2 conditions: power restore or system startup with a time delay. +========================+ | W a k e O n L A N | +========================+ Index MAC Address Delay T rigger Conditions [1] 00-0c-08-34-4d-57 001 (Power Restore)(System S tartup) [2] 00-00-00-00-00-00 000 [ ...

  • Minute Man SNMP-NET - page 13

    SNMP-NET 13 Chapter 4 Managing SNMP-NET Running the Web Browser (Internet Explorer) 1. Make sure that you have a TCP/IP network already installed. 2. If there is no DHCP network service on the network, contact your network administrator to get an IP address for you workstation that has the same network’ s address as the SNMP-NET IP address. The d ...

  • Minute Man SNMP-NET - page 14

    SNMP-NET 14 UPS Shutdown during Power Crisis UPS only: SNMP-NET responds to two dif ferent kinds of U PS shutdown events (AC failed, Battery Low). Go to Configure in the UPS M anagement menu and Login as an Admi nistrator . Set the options in UPS Shutdown Action section then press the Submit button. UPS + Shut down Software (SNMP-NET Client): If yo ...

  • Minute Man SNMP-NET - page 15

    SNMP-NET 15 SNMP Access Control Setting SNMP-NET support s SNMP protocol. Y ou c an use an NMS to manage the UPS through the network. The IP address of the workst ation mu st be entered in the SN MP-NET write access table to prevent unauthorized users from conf iguring SNMP-NET via SNMP protocols. Power Fail/Restore Simulation T o make sure the net ...

  • Minute Man SNMP-NET - page 16

    SNMP-NET 16 Chapter 5 Shutdown Software There are two kinds of shutdown software to help you to protect servers from power crisis. One is SNMP-NET Client the other one is the SN MP-NET ShutdownAgent. Both programs have the ability to shutdown servers gracefully . The major difference is the SNMP-NET ShutdownAgent can only receive SNMP traps of powe ...

  • Minute Man SNMP-NET - page 17

    SNMP-NET 17 Chapter 6 Specification Technical Specification Network Connection RJ-45 jack connector Operating T emperature 0 ~ 40 ° C Operating Humidity 10 ~ 80 % Power Input 9~24V DC Power Consumption 1 W att Maximum Size 130 mm x 60 mm (L x W) Weight 58 g Dipswitch Definition No. SW1 SW2 Function Mode 1 ON ON Console Configuration Mode 2 ON OFF ...

  • Minute Man SNMP-NET - page 18

    SNMP-NET 18 Chapter 7 Appendix Troubleshooting 1. How can I provide a SNTP (Simple Netw ork T imer Protocol) server for SNMP-NET? Solution: There are two ways to provide a network T ime Server for SNMP-NET : 1) Install the SNMP-NET Client software you can find it on the CD. 2) Install the “Simple TCP/IP Services” of “Networking Services” fr ...

  • Minute Man SNMP-NET - page 19

    SNMP-NET 19 6. Unable to perform an SNMP get operation. Solution: Check the SNMP settings stored in t he SNMP-NET . The IP Address of the PC you are using must be entered in one of the SNMP Access Control NMS IP fields, with Read or Read/Write permission. The Co mmunity S tring on the PC and SNMP-NET must match. 7. Unable to perform an SNMP set ope ...

  • Minute Man SNMP-NET - page 20

    SNMP-NET 20 Glossary Agent Implemented SNMP applications in network el ement s (hosts). Agent s perform the network management’s functions as requested by t he network administrator from an NMS. Ethernet Local Area Network technology , can link up to 1,024 no des in a bus network. Ethernet provides raw data tran sfer in a rate of 10 megabits/sec. ...

  • Minute Man SNMP-NET - page 21

    SNMP-NET 21 Obtaining Technical Assistance For T echnical Support on the Web, please visit the Support section of our Web site or visit our online Discussion Forum at www .minutemanups.com In order to diagnose the problem you are having, our technicians need the following information from you. Inst allation Site: C o m p a n y N a m e : A d d r e s ...

  • Minute Man SNMP-NET - page 22

    SNMP-NET 22 LIMITED PRODUCT WARRANTY Para System s Inc. (Para Syst ems) wa rrants this equipment, when pro perly applied and operated within specifie d conditions, against faulty materials or workman ship for a peri od of three years from the dat e of original purchase by the end user. For equipm ent sites within the United States and Canada, this ...

メーカー Minute Man カテゴリー Network card

Minute Man SNMP-NETのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SNMP-NETの取扱説明書
- Minute Manの製品カード
- パンフレット
- またはMinute Man SNMP-NETの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Minute Man SNMP-NETの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Minute Man SNMP-NETの取り付け説明書、サービスマニュアル、簡易説明書、またはMinute Man SNMP-NETのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Minute Man SNMP-NETの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Minute Man SNMP-NETデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMinute Man SNMP-NETを使用するのを助ける技術的文書のことです。説明書は通常、全てのMinute Man SNMP-NETユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Minute Manの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Minute Man SNMP-NETの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMinute Man SNMP-NETの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Minute Man SNMP-NETに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Minute Man SNMP-NETデバイスの基本機能を使うにあたってのヒント。 Minute Man SNMP-NETのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Minute Man SNMP-NETに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMinute Man SNMP-NETのメーカー/サービスへの連絡先に関する情報。

Minute Man SNMP-NETについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMinute Man SNMP-NETの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMinute Man SNMP-NETで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)