Pelco C1666M-A (4/06)の取扱説明書

20ページ 0.83 mb
ダウンロード

ページに移動 of 20

Summary
  • Pelco C1666M-A (4/06) - page 1

    INST ALLA TION TW3001AR Active Receiver Single Channel for UTP T ransmiss ion C1666M-A (4/06) ...

  • Pelco C1666M-A (4/06) - page 2

    ...

  • Pelco C1666M-A (4/06) - page 3

    C1666M-A (4/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install ...

  • Pelco C1666M-A (4/06) - page 4

    4 C1666M-A (4/06) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE ...

  • Pelco C1666M-A (4/06) - page 5

    C1666M-A (4/06) 5 Description The TW3001AR is a single-channel active receiver that can receive live video over unshielded twisted pair (UTP) cable. The adaptive technology in the TW3001AR automatical ly adjusts the low , medium and hig h frequency components of the video signal allowing for the best possibl e video transmission. The adaptive techn ...

  • Pelco C1666M-A (4/06) - page 6

    6 C1666M-A (4/06) PARTS OF THE RECEIVER Figure 1. TW3001AR Parts  Rubber Feet (4): For placing unit on a flat surfac e, such as a desk or shelf.  Status LED: Lights red when there is no UTP video bei ng received. Lights green when there is UTP video being received. Flashes a mber when Coaxitron pan/tilt /zoom (PTZ) control commands are being ...

  • Pelco C1666M-A (4/06) - page 7

    C1666M-A (4/06) 7 Installation Make sure all parts ar e present for the unit. 1 Universal power s upply (Part #PS04-1502-0512G) 1 Wall clip 1 2-pin power connector 1 2-pin UTP connector MOUNTING The TW3001AR receiver is 3 rack units hig h and can be mounted into a fiber rack, onto a wall using a fiber wall mount kit or in to the supplied wall clip. ...

  • Pelco C1666M-A (4/06) - page 8

    8 C1666M-A (4/06) USING A W ALL CLIP T o attach the TW3001AR receiver to a wall using t he supplied wall clip, refer to Figure 2 and do the following: 1. Attach the wall cl ip to a wall using two screws (not supplied). 2. Slide the receiver into the clip until the two holes on the bottom of the receiver align with the two holes on the lower flange ...

  • Pelco C1666M-A (4/06) - page 9

    C1666M-A (4/06) 9 SETTING THE DIP SWITCHES Y ou can override the adaptive technology by m anually adjusting switches 1 through 4 on the D IP Switch. The factory default switch positions are s hown in Figure 3. Switches 1 through 4 are set to AUTO and Switch 5 is set to H MODE (high mode). Figure 3. Default Switch Positions If you want to transmit v ...

  • Pelco C1666M-A (4/06) - page 10

    10 C1666M-A (4/06) APPLICATIONS Y ou can connect the TW3001AR active receiver to transmitters, such as the TW3001P passive trans- ceiver and the TW3001A T active transmitter , and to Pelco UTP ca meras, such as the CC3710/CC3610 Series. Although you can connect these products using an unshiel ded twisted pair Cat3 and Cat5 cable, Cat5e and Cat6 are ...

  • Pelco C1666M-A (4/06) - page 11

    C1666M-A (4/06) 11 Figure 4 shows a TW3001AR connected to a UTP Camclosure ® . Figure 4. TW3001AR Connected to a UTP Camclosure + - CAMCLOSURE TW3001AR UTP MONITOR 12 VDC OR 24 VAC POWER SUPPLY BLUE WIRE = GRAY WIRE = POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 12

    12 C1666M-A (4/06) Figure 5 shows a TW3001AR connected to a UTP fixed camera. Figure 5. TW3001AR Connected to a UTP Fixed Camera + - TW3001AR FIXED CAMERA 8 PINS (4-/5+) MONITOR UTP PIN 5 + PIN 4 - 10 PINS (5-/6+) 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 13

    C1666M-A (4/06) 13 Figure 6 shows a TW3001AR connected to a UTP Spectra ® Dome for Coaxitron PTZ control. Figure 6. TW3001AR Connected to a Spectra Dome + - TW3001AR UTP VIDEO COAXITRON SPECTRA MONITOR MATRIX VC-UTP BOARD 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 14

    14 C1666M-A (4/06) Figure 7 shows a TW3001AR connected to a TW 3001P passive transceiver . The TW3001P then connects to a non-UTP fixed camera. Figure 7. TW3001AR Connected to a Single Passive T ransceiver + - TW3001AR TW3001P UTP MONITOR DIRECT CONNECTION FIXED CAMERA 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 15

    C1666M-A (4/06) 15 Figure 8 shows a TW3001AR connected to a TW3032P passive transceiver . Figure 8. TW3001AR Conn ected to a 32-Channel Passive T ransceiver + - TW3001AR TW3032P MONITOR UTP 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 16

    16 C1666M-A (4/06) Figure 9 shows a TW3001AR connected to a TW 3004P passive transceiver . The TW3004P then connects to a non-UTP fixed camera. Figure 9. TW3001AR Connected to a 4-Channel Passive T ransceiver + - TW3001AR TW3004P 1 2 3 4 UTP MONITOR FIXED CAMERA 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR ...

  • Pelco C1666M-A (4/06) - page 17

    C1666M-A (4/06) 17 Specifications ELECTRICAL Input V oltage 12 VDC or 24 V AC, 50-60Hz Power Consumption 2.5 W Wire T ype Unshielded twis ted pair (24 AWG maximum) Wire Category Cat3 or better DC Loop Resistance 52 ohms per 1,000 feet Differential Capacitance 19pF/ft max T ransient Immunity 300 W peak pulse power (8/20 US) VIDEO CHARACTERISTICS Vid ...

  • Pelco C1666M-A (4/06) - page 18

    18 C1666M-A (4/06) ...

  • Pelco C1666M-A (4/06) - page 19

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise proved defective in materi al or workma nship for a period of one year after the date of shipment. Exception s to this warrant y are as noted be low: • Five years on FR/F T/FS Series fiber optic pr oducts and TW300 0 Series unshielde d ...

  • Pelco C1666M-A (4/06) - page 20

    Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Arab E ...

メーカー Pelco カテゴリー Home Security System

Pelco C1666M-A (4/06)のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C1666M-A (4/06)の取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C1666M-A (4/06)の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C1666M-A (4/06)の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C1666M-A (4/06)の取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C1666M-A (4/06)のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C1666M-A (4/06)の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C1666M-A (4/06)デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C1666M-A (4/06)を使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C1666M-A (4/06)ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C1666M-A (4/06)の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C1666M-A (4/06)の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C1666M-A (4/06)に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C1666M-A (4/06)デバイスの基本機能を使うにあたってのヒント。 Pelco C1666M-A (4/06)のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C1666M-A (4/06)に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C1666M-A (4/06)のメーカー/サービスへの連絡先に関する情報。

Pelco C1666M-A (4/06)についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C1666M-A (4/06)の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C1666M-A (4/06)で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)