Summary
  • APC Smart-UPS 1000VA LCD 230V - page 1

    Operation Manual Smart-UPS ® UPS 750/1000/1500/2200/3000 V A T ower 120/230 V AC ...

  • APC Smart-UPS 1000VA LCD 230V - page 2

    Content s Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower i Overview ....................................... ................................... 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • APC Smart-UPS 1000VA LCD 230V - page 3

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower ii Emergency Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EPO Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Normally open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 No ...

  • APC Smart-UPS 1000VA LCD 230V - page 4

    1 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 750-3000 V A 120/230 V ac T ow er is a high performan ce Uninterruptible Power Supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and sur ges; small utility ...

  • APC Smart-UPS 1000VA LCD 230V - page 5

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 2 Rear p a nels  USB port 750 V A 120 V ac 750 V A 230 V ac  Serial port  Ground screw  Smart slot  Circuit breaker  UPS input  Outlets  EPO connector 1000/1500 V A 120 V ac 1000/1500 V A 230 V ac 2200 V A 120 V ac/3000 V A 120 V ac† 2200/3000 V A 230 V ac †Circuit ...

  • APC Smart-UPS 1000VA LCD 230V - page 6

    3 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Specifications Operating Conditions This unit is intended for indoor use only . Select a location sturdy enough to support the weight of the UPS. Do not operate the unit where there is excessive dust, or the temperature or humidity are outside the specified limits. This unit has side air ve ...

  • APC Smart-UPS 1000VA LCD 230V - page 7

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 4 Operation Connect Equipment to the UPS Note: The UPS will char ge to 90% capacity in th e first three hours of normal operation. Do not expect full battery run capability during this i nitial charge period. 1. Connect equipment to the outlets on the rear panel o f the UPS. Do not use extensi ...

  • APC Smart-UPS 1000VA LCD 230V - page 8

    5 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Display Interface Overview Using the display interface Use U P and D OWN to scroll through the main menu options. Press E NTER to view the sub-menus unde r each main menu option. Press E SCAPE to exit a sub-menu and return to a mai n menu. St andard menus The Standard menus are the most co ...

  • APC Smart-UPS 1000VA LCD 230V - page 9

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. About Display information about thi s unit: • Unit model nu mber • Serial number • Battery installation date • Suggested ...

  • APC Smart-UPS 1000VA LCD 230V - page 10

    7 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute ® software. Note: During start-up, use the display interface to configure these settings. If nothing is selected, the until will u se the default settin ...

  • APC Smart-UPS 1000VA LCD 230V - page 11

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 8 Low T ransfer Point 120 V : 106 V ac • 97 V ac • 100 V ac • 103 V ac • 106 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this condition.This setting may also be adjusted using the power quality setting. Note: Use ...

  • APC Smart-UPS 1000VA LCD 230V - page 12

    9 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Main Outlet Group and the Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be conf igured to independentl y turn off, turn on, shut down, and reboot conn ected equipment. (Th ese features are not available on the 750 V A units.) The Main Outlet Group a ...

  • APC Smart-UPS 1000VA LCD 230V - page 13

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 10 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory . These settings can only be modified using an external interface, like the NMC web interface. • NMC IP Address Mode • NMC IP Address • NMC ...

  • APC Smart-UPS 1000VA LCD 230V - page 14

    11 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer Emergency Power Off EPO Overview The Emergency Power Of f (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . The UPS must be manually re-started to re-app ...

  • APC Smart-UPS 1000VA LCD 230V - page 15

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 12 T roubleshooting Problem and P ossible Cause Solution The UPS will not turn on or ther e is no output The unit has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility power . Ensure that the power cable is securely connected to the unit and t ...

  • APC Smart-UPS 1000VA LCD 230V - page 16

    13 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer The replace battery i ndicator is illuminated The battery has a weak charge. Allow the battery to rechar ge for at least four hours. Then, perform a self-test. If the problem persists after recharging, replace the battery . The replacement battery is not properly connected. Ensure that the ...

  • APC Smart-UPS 1000VA LCD 230V - page 17

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 14 Service and Support Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r oubleshooting section of the UPS manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .a ...

  • APC Smart-UPS 1000VA LCD 230V - page 18

    15 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer T ransport the unit 1. Shut down and disconnect all connected equipment. 2. Disconnect the unit from utility power . 3. Disconnect all internal and ex ternal batteries (if applicable). 4. Follow the shipping instructions outlined in the Service . APC Worldwide Customer Support Customer sup ...

  • APC Smart-UPS 1000VA LCD 230V - page 19

    Smart-UPS Factory W arranty LIMITED W ARRANTY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date of purchase. APC's obligation under this warranty is limited to repairin ...

  • APC Smart-UPS 1000VA LCD 230V - page 20

    Harmonized S tandards EN62040-1-1, EN62040-2, EN6095 0-1, IEC60950-1, EN550 22, EN55024, IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-1 1 Applicable Council Directives 2006/95/EC; 2004/108/EC T y pe of Equipment Uninterruptible Power Sup ply Model Numbers SMT750I, SMT1000I, SMT 1500I, SMT2200I, SMT3000I Manufacturers American Power Conversion 132 ...

  • APC Smart-UPS 1000VA LCD 230V - page 21

    06/2009 990-3534-0 01 © 2009 APC by Schneider Electric. APC, the APC logo are owned by Schneide r Electric Industries S.A.S., American Power Conversion Co rporation, or their affiliat ed companies. All other tr ademarks are proper ty of their respective owners. ...

メーカー APC カテゴリー Uninterruptible power supply (

APC Smart-UPS 1000VA LCD 230Vのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Smart-UPS 1000VA LCD 230Vの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC Smart-UPS 1000VA LCD 230Vの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC Smart-UPS 1000VA LCD 230Vの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC Smart-UPS 1000VA LCD 230Vの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC Smart-UPS 1000VA LCD 230Vのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC Smart-UPS 1000VA LCD 230Vの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC Smart-UPS 1000VA LCD 230Vデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC Smart-UPS 1000VA LCD 230Vを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC Smart-UPS 1000VA LCD 230Vユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC Smart-UPS 1000VA LCD 230Vの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC Smart-UPS 1000VA LCD 230Vの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC Smart-UPS 1000VA LCD 230Vに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC Smart-UPS 1000VA LCD 230Vデバイスの基本機能を使うにあたってのヒント。 APC Smart-UPS 1000VA LCD 230Vのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC Smart-UPS 1000VA LCD 230Vに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC Smart-UPS 1000VA LCD 230Vのメーカー/サービスへの連絡先に関する情報。

APC Smart-UPS 1000VA LCD 230Vについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC Smart-UPS 1000VA LCD 230Vの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC Smart-UPS 1000VA LCD 230Vで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)