Manual APC Smart-UPS 1000VA LCD 230V

21 pages Not applicable
Download

Go to site of 21

Summary
  • APC Smart-UPS 1000VA LCD 230V - page 1

    Operation Manual Smart-UPS ® UPS 750/1000/1500/2200/3000 V A T ower 120/230 V AC ...

  • APC Smart-UPS 1000VA LCD 230V - page 2

    Content s Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower i Overview ....................................... ................................... 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • APC Smart-UPS 1000VA LCD 230V - page 3

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower ii Emergency Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EPO Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Normally open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 No ...

  • APC Smart-UPS 1000VA LCD 230V - page 4

    1 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 750-3000 V A 120/230 V ac T ow er is a high performan ce Uninterruptible Power Supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and sur ges; small utility ...

  • APC Smart-UPS 1000VA LCD 230V - page 5

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 2 Rear p a nels  USB port 750 V A 120 V ac 750 V A 230 V ac  Serial port  Ground screw  Smart slot  Circuit breaker  UPS input  Outlets  EPO connector 1000/1500 V A 120 V ac 1000/1500 V A 230 V ac 2200 V A 120 V ac/3000 V A 120 V ac† 2200/3000 V A 230 V ac †Circuit ...

  • APC Smart-UPS 1000VA LCD 230V - page 6

    3 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Specifications Operating Conditions This unit is intended for indoor use only . Select a location sturdy enough to support the weight of the UPS. Do not operate the unit where there is excessive dust, or the temperature or humidity are outside the specified limits. This unit has side air ve ...

  • APC Smart-UPS 1000VA LCD 230V - page 7

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 4 Operation Connect Equipment to the UPS Note: The UPS will char ge to 90% capacity in th e first three hours of normal operation. Do not expect full battery run capability during this i nitial charge period. 1. Connect equipment to the outlets on the rear panel o f the UPS. Do not use extensi ...

  • APC Smart-UPS 1000VA LCD 230V - page 8

    5 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Display Interface Overview Using the display interface Use U P and D OWN to scroll through the main menu options. Press E NTER to view the sub-menus unde r each main menu option. Press E SCAPE to exit a sub-menu and return to a mai n menu. St andard menus The Standard menus are the most co ...

  • APC Smart-UPS 1000VA LCD 230V - page 9

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. About Display information about thi s unit: • Unit model nu mber • Serial number • Battery installation date • Suggested ...

  • APC Smart-UPS 1000VA LCD 230V - page 10

    7 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute ® software. Note: During start-up, use the display interface to configure these settings. If nothing is selected, the until will u se the default settin ...

  • APC Smart-UPS 1000VA LCD 230V - page 11

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 8 Low T ransfer Point 120 V : 106 V ac • 97 V ac • 100 V ac • 103 V ac • 106 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this condition.This setting may also be adjusted using the power quality setting. Note: Use ...

  • APC Smart-UPS 1000VA LCD 230V - page 12

    9 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Main Outlet Group and the Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be conf igured to independentl y turn off, turn on, shut down, and reboot conn ected equipment. (Th ese features are not available on the 750 V A units.) The Main Outlet Group a ...

  • APC Smart-UPS 1000VA LCD 230V - page 13

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 10 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory . These settings can only be modified using an external interface, like the NMC web interface. • NMC IP Address Mode • NMC IP Address • NMC ...

  • APC Smart-UPS 1000VA LCD 230V - page 14

    11 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer Emergency Power Off EPO Overview The Emergency Power Of f (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . The UPS must be manually re-started to re-app ...

  • APC Smart-UPS 1000VA LCD 230V - page 15

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 12 T roubleshooting Problem and P ossible Cause Solution The UPS will not turn on or ther e is no output The unit has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility power . Ensure that the power cable is securely connected to the unit and t ...

  • APC Smart-UPS 1000VA LCD 230V - page 16

    13 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer The replace battery i ndicator is illuminated The battery has a weak charge. Allow the battery to rechar ge for at least four hours. Then, perform a self-test. If the problem persists after recharging, replace the battery . The replacement battery is not properly connected. Ensure that the ...

  • APC Smart-UPS 1000VA LCD 230V - page 17

    Smart-UPS 750/1000/1500/2200 /3000 VA 120/230 Vac Tower 14 Service and Support Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r oubleshooting section of the UPS manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .a ...

  • APC Smart-UPS 1000VA LCD 230V - page 18

    15 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac To wer T ransport the unit 1. Shut down and disconnect all connected equipment. 2. Disconnect the unit from utility power . 3. Disconnect all internal and ex ternal batteries (if applicable). 4. Follow the shipping instructions outlined in the Service . APC Worldwide Customer Support Customer sup ...

  • APC Smart-UPS 1000VA LCD 230V - page 19

    Smart-UPS Factory W arranty LIMITED W ARRANTY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date of purchase. APC's obligation under this warranty is limited to repairin ...

  • APC Smart-UPS 1000VA LCD 230V - page 20

    Harmonized S tandards EN62040-1-1, EN62040-2, EN6095 0-1, IEC60950-1, EN550 22, EN55024, IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-1 1 Applicable Council Directives 2006/95/EC; 2004/108/EC T y pe of Equipment Uninterruptible Power Sup ply Model Numbers SMT750I, SMT1000I, SMT 1500I, SMT2200I, SMT3000I Manufacturers American Power Conversion 132 ...

  • APC Smart-UPS 1000VA LCD 230V - page 21

    06/2009 990-3534-0 01 © 2009 APC by Schneider Electric. APC, the APC logo are owned by Schneide r Electric Industries S.A.S., American Power Conversion Co rporation, or their affiliat ed companies. All other tr ademarks are proper ty of their respective owners. ...

Manufacturer APC Category Uninterruptible power supply (

Documents that we receive from a manufacturer of a APC Smart-UPS 1000VA LCD 230V can be divided into several groups. They are, among others:
- APC technical drawings
- Smart-UPS 1000VA LCD 230V manuals
- APC product data sheets
- information booklets
- or energy labels APC Smart-UPS 1000VA LCD 230V
All of them are important, but the most important information from the point of view of use of the device are in the user manual APC Smart-UPS 1000VA LCD 230V.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals APC Smart-UPS 1000VA LCD 230V, service manual, brief instructions and user manuals APC Smart-UPS 1000VA LCD 230V. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product APC Smart-UPS 1000VA LCD 230V.

A complete manual for the device APC Smart-UPS 1000VA LCD 230V, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use APC Smart-UPS 1000VA LCD 230V by users. Manuals are usually written by a technical writer, but in a language understandable to all users of APC Smart-UPS 1000VA LCD 230V.

A complete APC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual APC Smart-UPS 1000VA LCD 230V - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the APC Smart-UPS 1000VA LCD 230V, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the APC Smart-UPS 1000VA LCD 230V, that we can find in the current document
3. Tips how to use the basic functions of the device APC Smart-UPS 1000VA LCD 230V - which should help us in our first steps of using APC Smart-UPS 1000VA LCD 230V
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with APC Smart-UPS 1000VA LCD 230V
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of APC Smart-UPS 1000VA LCD 230V in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning APC Smart-UPS 1000VA LCD 230V?

Use the form below

If you did not solve your problem by using a manual APC Smart-UPS 1000VA LCD 230V, ask a question using the form below. If a user had a similar problem with APC Smart-UPS 1000VA LCD 230V it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)