    OPERA T OR’S MANUAL Cat. No. 2260-21 M12™ 160x120 Thermal Imager        ...

  • Milwaukee 2260-21 - page 2

     Safety Information ................................................................................................................................ 1 Introduction ............................................................................................................................................ 3 How to Use the Manu ...

  • Milwaukee 2260-21 - page 3

    M12 160x120 Thermal Imager Operator's Manual 1         Failure to follow the warnings and instructions may result in electric shock, re and/o ...

  • Milwaukee 2260-21 - page 4

    2 M12 160x120 Thermal Imager Operator ’s Manual Federal Communications Commission W ARNING: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the user ’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital devi ...

  • Milwaukee 2260-21 - page 5

    M12 160x120 Thermal Imager Operator's Manual 3 226 174.3˚F 98 Figure 1. Thermal Imager and a Thermal Image  Model 2260-21 M12™ 160x120 Thermal Imager is an ultra-rugged, hand-held battery-powered tool that takes thermal pictures, called “thermal images.” Thermal images reveal different temperatures as ...

  • Milwaukee 2260-21 - page 6

    4 M12 160x120 Thermal Imager Operator ’s Manual  All of the manuals needed to safely and properly operate the Thermal Imager are available in Adobe ® PDF (Portable Document Format) on the CD. Y ou can easily load these PDF documents from the CD or from the MIL WAUKEE website onto ...

  • Milwaukee 2260-21 - page 7

    M12 160x120 Thermal Imager Operator's Manual 5   Visit www .milwaukeetool.com online and click on Service. There you can search for the nearest factory authorized Service Center . Y ou can also nd how to contact someone at MI ...

  • Milwaukee 2260-21 - page 8

    6 M12 160x120 Thermal Imager Operator ’s Manual  The complete system comes packed in a rugged portable hard case. Figure 2 and T able 1 identify each item. If anything is missing, contact the point of purchase. Figure 2. Identifying Items in the Hard Case 2 1 4 5 3 6 SD SD CARD READER US ...

  • Milwaukee 2260-21 - page 9

    M12 160x120 Thermal Imager Operator's Manual 7 No. Item Model or Part Number 1 Hard Carry Case 42-55-2265 2 Reference Card 58-22-0240 3 Product CD with software and manuals in PDF format 58-99-0015 4 W arranty and Safety Information booklet 22-74-3005 5 M12 160 x120 Thermal Imager 2260-20 6 M12 Battery Charger and Battery Operator ’s Manual ...

  • Milwaukee 2260-21 - page 10

    8 M12 160x120 Thermal Imager Operator ’s Manual 3. T o remove it, press it in gently and it releases so you can pull it out. 4. If an SD card is not installed, insert the SD card with the label facing the front of the Thermal Imager (the side with the lens). It ts only one way . Do not use excessive force. 5. Gently press it until the SD card ...

  • Milwaukee 2260-21 - page 11

    M12 160x120 Thermal Imager Operator's Manual 9  Figure 4 and T able 2 identify the location and explain the function of the buttons, controls and features. See T able 3 for a list of all the symbols printed on the Thermal Imager and the meaning of each. Figure 5 and T able 3 explai ...

  • Milwaukee 2260-21 - page 12

    10 M12 160x120 Thermal Imager Operator ’s Manual T able 2. Controls and Features No. Name Function 1 Hand grip Grip this when you use the Thermal Imager . The hand grip also holds the removable M12 rechargeable battery . 2 Mini USB socket Plug the USB cable into this socket when you want to connect the Thermal Imager to a computer . This is one w ...

  • Milwaukee 2260-21 - page 13

    M12 160x120 Thermal Imager Operator's Manual 1 1 No. Name Function 13 (T oggle button) Press to toggle between thermal image display and visual image display . The toggle button works in both live view and image review . 14 (Back button) Press to revert to the most recent operating condition. 15, 16 This part of the keypad has up, down, left a ...

  • Milwaukee 2260-21 - page 14

    12 M12 160x120 Thermal Imager Operator ’s Manual Figure 5. Elements of the Thermal Image Display 226 174.3˚F 98 7 6 5 8 4 1 2 3 T able 4. Explanation of Display Elements 1 LED ashlight is on 2 SD card is not installed (you cannot save images) 3 T arget temperature 4 T arget 5 Battery charge indicator (more white = more charge remaining) 6 Upp ...

  • Milwaukee 2260-21 - page 15

    M12 160x120 Thermal Imager Operator's Manual 13 LO W BA TTER Y 100% 75% 50% 25% <10% Figure 6. Battery Fuel Gauge Levels and Imminent Shutdown W arning   T o preserve battery life, the Thermal Imager goes into Sleep Mode after 5 ...

  • Milwaukee 2260-21 - page 16

    14 M12 160x120 Thermal Imager Operator ’s Manual   Proceed as follows to capture and save a basic image set:   ...

  • Milwaukee 2260-21 - page 17

    M12 160x120 Thermal Imager Operator's Manual 15 230 138.9˚F 95 CANCEL SA VE Figure 9. SA VE or CANCEL a New Image 7. T o write the image to SD card, press the button on the arrow keypad or pull the trigger again. Or , to discard the image, press the arrow button to highlight CANCEL, then press the button.   ...

  • Milwaukee 2260-21 - page 18

    16 M12 160x120 Thermal Imager Operator ’s Manual Figure 10. Live Visual Camera V iew Press again to return to the thermal image view .   Every time you take a thermal picture, the Thermal Imager captures a visual image at the same tim ...

  • Milwaukee 2260-21 - page 19

    M12 160x120 Thermal Imager Operator's Manual 17 • Auto or Manual Range (default is Auto) – Gives you control over the lowest and highest temperature. • Span (default is the Imager ’s Range, or widest temperature range from lowest to highest temperature that the Imager can detect). A custom span setting lets you narrow the range o ...

  • Milwaukee 2260-21 - page 20

    18 M12 160x120 Thermal Imager Operator ’s Manual Emissivity is the ratio of a target surface’s infrared output (radiance) to that of a blackbody at the same temperature. A “blackbody” is a theoretical perfect radiator of infrared radiation (IR). What this means is you can set the sensitivity of the Thermal Imager to determine the true tempe ...

  • Milwaukee 2260-21 - page 21

    M12 160x120 Thermal Imager Operator's Manual 19   When you turn on the Thermal Imager , it is always in AUTO RANGE mode. This means that it automatically selects the lowest temperature and highest temperature in its range to make thermal images. Usually , this pro ...

  • Milwaukee 2260-21 - page 22

    20 M12 160x120 Thermal Imager Operator ’s Manual 2. Press to select MANUAL range. The display appears as in Figure 13 (this example is using a different target image): LEVEL SP AN 70 66.2˚F 50 Figure 13. Setting Level and Span for Manual Range 3. Press and to experiment with the SP AN setting to choose the best looking display for the area you a ...

  • Milwaukee 2260-21 - page 23

    M12 160x120 Thermal Imager Operator's Manual 21 1. From the live view mode, press then if needed to select COLOR, then . This opens the menu bar shown in Figure 14. Press the and arrow buttons to make your selection, then press to conrm it.  The default color pale ...

  • Milwaukee 2260-21 - page 24

    22 M12 160x120 Thermal Imager Operator ’s Manual 1 Press and to select the menu item to set, followed by t to conrm your slection. 2. Press and to change the setting, followed by to conrm the change. Changes you make to settings remain in effect even after you turn of f the power and turn it back on again. ? ...

  • Milwaukee 2260-21 - page 25

    M12 160x120 Thermal Imager Operator's Manual 23  PHYSICAL AND ENVIRONMENT AL Drop test 3’ (1m) drop to concrete Operating temperature range 14°F to 122°F (-10°C to +50°C) Operating and storage humidity range 10% to 90%, non-condensing Storage temperature range without battery1 -13°F to 140°F (-25? ...

  • Milwaukee 2260-21 - page 26

    24 M12 160x120 Thermal Imager Operator ’s Manual VISUAL IMAGING Visual digital camera resolution 1.3 Megapixels Field of View 56º Horizontal X 46º V ertical Minimum distance in focus 1 1.8 in. (30 cm) Focus method Fixed Exposure control Auto LED ashlight3 User-selectable on or off GENERAL Battery system MIL WAUKEE M12 Series rechargeable Li- ...

  • Milwaukee 2260-21 - page 27

    M12 160x120 Thermal Imager Operator's Manual 25  T erm Denition 160x120 The number of pixels (picture elements or dots) in a saved thermal image. Each pixel has a temperature associated with it. Each thermal image is 160 pixels wide by 120 pixels high. accuracy The guaranteed correctness of a temperature reading. For ...

  • Milwaukee 2260-21 - page 28

    26 M12 160x120 Thermal Imager Operator ’s Manual CD Compact Disk. Also called a CD ROM, for CD Read-Only Memory . The CD supplied with the Thermal Imager contains software and manuals. Celsius A temperature scale based on 0 °C as the freezing point of water and 100 °C as the boiling point of water at a reference barometric pressure. color palet ...

  • Milwaukee 2260-21 - page 29

    M12 160x120 Thermal Imager Operator's Manual 27 xed focus An optical system for a camera or thermal imager that is set to one average distance, resulting in an in-focus range that is not adjustable. FP A (focal-plane array) A rectangular at-panel matrix of detector elements on which the Thermal Imager ’s optical lenses and lters foc ...

  • Milwaukee 2260-21 - page 30

    28 M12 160x120 Thermal Imager Operator ’s Manual infrared (IR) Electromagnetic energy in wavelengths that are between visible light and RF (radio frequency). infrared detector A transducer element (sensor) that converts incoming radiant infrared energy striking its surface into an electrical signal. The Thermal Imager measures this signal and tra ...

  • Milwaukee 2260-21 - page 31

    M12 160x120 Thermal Imager Operator's Manual 29 menu On the Thermal Imager , a menu is a list of choices you can make for settings, such as time, date, color palette, span and emissivity . microbolometer The type of thermal infrared detector used in the Thermal Imager . It is an array of 160 by 120 thermal sensors that respond to infrared radi ...

  • Milwaukee 2260-21 - page 32

    30 M12 160x120 Thermal Imager Operator ’s Manual resolution Same as “thermal sensitivity .” The number of meaningful digits in a temperature reading, for example, “10 °C, 10.1 °C, or 10.01 °C.” For the 10.01 °C reading, the resolution is “0.01 °C.” saved image An image written (recorded) onto the SD card installed in the Thermal ...

  • Milwaukee 2260-21 - page 33

    M12 160x120 Thermal Imager Operator's Manual 31 storage temperature The lowest ambient temperature to the highest ambient temperature in which you can store the Thermal Imager while it is not being used. target The area in a thermal image in the center , dened by square corner markers on the display , whose temperature is displayed in 0.1 d ...

  • Milwaukee 2260-21 - page 34

    32 M12 160x120 Thermal Imager Operator ’s Manual toggle Press the button to switch between thermal visual image display and visual image display . the display This works in live mode as well as in image review mode. trigger The nger-lever at the top of the hand grip that you to take a thermal image. Pull it once to take the image and pull it a ...

  • Milwaukee 2260-21 - page 35

    M12 160x120 Thermal Imager Operator's Manual 33 ...

  • Milwaukee 2260-21 - page 36

    MIL W AUKEE ELECTRIC TOOL CORPORA TION 13135 West Lisbon Road • Brookeld, Wisconsin, USA 53005 58-14-2260 1 1/1 1         ? ...

メーカー Milwaukee カテゴリー Home Safety Product

Milwaukee 2260-21のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2260-21の取扱説明書
- Milwaukeeの製品カード
- パンフレット
- またはMilwaukee 2260-21の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Milwaukee 2260-21の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Milwaukee 2260-21の取り付け説明書、サービスマニュアル、簡易説明書、またはMilwaukee 2260-21のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Milwaukee 2260-21の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Milwaukee 2260-21デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMilwaukee 2260-21を使用するのを助ける技術的文書のことです。説明書は通常、全てのMilwaukee 2260-21ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Milwaukeeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Milwaukee 2260-21の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMilwaukee 2260-21の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Milwaukee 2260-21に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Milwaukee 2260-21デバイスの基本機能を使うにあたってのヒント。 Milwaukee 2260-21のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Milwaukee 2260-21に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMilwaukee 2260-21のメーカー/サービスへの連絡先に関する情報。

Milwaukee 2260-21についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMilwaukee 2260-21の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMilwaukee 2260-21で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)