    MIL W AUKEE ELECTRIC T OOL CORPORA TION – TEST & MEASUREMEN T PRODUCT REP AIR SER VICE INSTRUCTIONS — CALIBRA TION 2 216- 20 Light Commercial Digital Multimeter Environmental Condition Perform all calibration at an ambient temperature of 23°C ± 2°C / 73.4°F ± 3.6°F a nd relative humidity of 80% - allow the digital multimeter to si t a ...

  • Milwaukee 2216-20 - page 2

    i T ABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 S pecifications 3 General S pecification 3 V oltage S pecif ication 4 Current S pecifications 5 Resist ance, Continuity , Capacit ance S pecifications 6 Frequency , Rotary Switch, Auto Power Of f S pecification 7 Physical and environment characteristics ...

  • Milwaukee 2216-20 - page 3

    1 Introduction W arning T o avoid shock or injury , do not perform the verification test s or calibration procedu res described in the manual unless y ou are qualified to do so. The information provided in this document is for the use of qu alified personnel only . Caution The 2216-20 cont ain p art s that can be damaged by st atic discharge. Follo ...

  • Milwaukee 2216-20 - page 4

    2 SAFETY Review the following safety precaution s to avoid injury and prevent damag e to this product or any product s connected to it. T o avoid potential hazards, use the product only as spe cified. CAUTION: These st atement s identify conditions or practices that could result in damage to the equipment or other pro perty . W ARNING: These statem ...

  • Milwaukee 2216-20 - page 5

    3 SPECIFICA TIONS All specifications are warranted unless noted typical and apply to the 2216 -20 DMM. S tated accuracies are at 23°C±5°C at tha n 80% relative humidity and without the battery indicator displayed. Gen era l sp ec ifi ca tions n o i t p i r c s e D s c i t s i r e t c a r a h C s t n u o c 0 0 0 6 t n u o c y a l p s i D c e s / ...

  • Milwaukee 2216-20 - page 6

    4 Measurement Characteris tics Accuracy is ±(% reading + number of digit s) at 23°C ± 5°C, less than 80% R.H. T emperature coeffici ent: 0.1 * (S pecifi ed accuracy)/°C , < 18°C , > 28°C (1) DC V olt age Range Resolution Accuracy 600.0mV 0.1mV 6.000V 0.001V 60.00V 0.01V 600.0V 0.1V ± (0.5% reading + 2 digits) Input Impedance: 10M Ω ...

  • Milwaukee 2216-20 - page 7

    5 (3) DC Current Range Resolution Accuracy 6.000A 0.001A 10.00A 0.01A ± (1% reading + 3 digit s) Response Ti me: < 1.5 sec. Maximum measurement time: 5 minutes at 10A with at least 20 minutes rest time. Overload Protection: AC/D C 20A for 10 sec ond. (4) AC Current Range Resolution Accuracy (Sine W av e) 6.000A * 0.001A 10.00A 0.01A ± (1.5% re ...

  • Milwaukee 2216-20 - page 8

    6 (6) Continuity Range Resolution Accuracy 600.0 Ω 0.1 Ω ± (1% reading + 5 digit s) Open Circuit V olt age: Approx. 0.6V Continuity: Built-in buzzer sounds whe n measured resistance i s less than 30 Ω and sounds off when measured resist ance is more than 200 Ω , Between 30 Ω to 200 Ω the buzzer maybe sound or of f either . Continuity I ...

  • Milwaukee 2216-20 - page 9

    7 (1 1) Auto Po wer Off The meter au tomatically turns the power off after powering up and no operation for 20 ± 5 minutes. T o power up, turn the knob back to OFF f irst. (12) Measuring Rate: 3 t i mes / sec. (13) Fuse: 10A/600V Fast Action Fuse (1 4) Batt er y : Alkaline 1.5V Battery * 2 (15) Low Battery V oltage: 2.3V ± 0.1V (16) Backlight The ...

  • Milwaukee 2216-20 - page 10

    8 Physical and Environment al Characteri stics n o i t p i r c s e D s c i t s i r e t c a r a h C Dime nsio ns (H ×W ×D) 170mm × 80mm × 57m m g K 3 . 0 ) y r e t t a b h t i w ( t h g i e W n o i t p i r c s e D s c i t s i r e t c a r a h c l a t n e m n o r i v n E C ° 0 5 + o t 0 1 - g n i t a r e p o e r u t a r e p m e T Non-Operating -4 ...

  • Milwaukee 2216-20 - page 11

    9 Required Equipment Required equipment is listed in T able B. If the recommended models are not available, equip ment with equivalent specifications may be used. Repairs or se rvicing should be per formed only by qualified personn el. T able B. Required Equipment Equipment Required Characteristics Recommended Model Calibrator AC Voltage Range: 0 ? ...

  • Milwaukee 2216-20 - page 12

    10 Basic Maintenance W arning T o avoid shock, remove the test leads an d any input signals before opening the case o r replacing the battery or fuses. Opening the Meter Ca se Caution T o avoid unintentional shock circuit, always place the uncovered Meter assembl y on a protective surface. When the ca se of the Meter is open, circuit connections ar ...

  • Milwaukee 2216-20 - page 13

    11 T esting Fuses T o test the internal fuses of the meter . 1. T urn the rotary selector s witch to the Ω position. 2. T o test FS1, plug a test lead into V Ω Hz input terminal, and touch the probe to the A input terminal. The displ ay should indicate between 0.0 to 0.2 Ω . (Bussmann KTK-10 recommended). If display reads higher than 0.2 Ω ...

  • Milwaukee 2216-20 - page 14

    12 Performance T est s The following performance test s verify the co mplete operability of the Meter an d check the accuracy of each Meter function against the Meter’s specifications. Accuracy specificatio ns are valid for a period of one year after calibration, when measured at an operating temperature of 18°C to 28°C and at A maximum of 80% ...

  • Milwaukee 2216-20 - page 15

    13 T esting the V olt age Function To verify accuracy in the AC and DC voltage ranges, do the following: 1. T urn t he ro t ar y switch to “ V ” position . 2. Connect the Calibrator to the V Ω and CO M inputs on the Meter. 3. Set the Calibrator for the voltage and frequency from step 1 to 12 in Table 1. 4. Compare the reading on the Meter dis ...

  • Milwaukee 2216-20 - page 16

    14 T esting the Resist ance Function T o verify the accuracy of the resist ance function, do the following: 1. Connect the Calibrator to V Ω Hz and CO M on t he Me ter . 2. T u rn t he ro tary swi tch to Ω . 3. Apply the inputs for st ep 1-6 in T able 3. 4. Compare the Meter display readings to the displ ay readings in T able 3. 5. If the displa ...

  • Milwaukee 2216-20 - page 17

    15 T esting the Ampere Function T o verify the accuracy of AC current measurement function s, do the following: 1. Connect the Calibrator to the A and CO M inpu t s on t he Me ter . 2. T u rn the ro ta ry swit ch to A~. 3. Apply the inputs for step s 1-4 in T able 5. 4. For each input, comp are the readings on the Meter display to the reading in T ...

  • Milwaukee 2216-20 - page 18

    16 T able 7 Frequency T est: Step Source Level Waveform Readin g 1 8.0Vp-p 2.00Hz Square Wa ve 1.98Hz to 2.02Hz 2 8.0Vp-p 80.00Hz Square Wa ve 79.90Hz to 80.10Hz 3 8.0Vp-p 800.0Hz Square Wa ve 799.0Hz to 801.0Hz 4 8.0Vp-p 8.000kHz Square Wa ve 7.990kHz to 8.010kHz 5 10.0Vp-p 50.00kHz Square Wave 49.93kHz to 50.07kHz 6 230.0Vp-p 10.00 Hz Sine Wave 9 ...

  • Milwaukee 2216-20 - page 19

    17 Calibration Procedure Recalibrate the meter: It is recommended that the meter may be calibrated once year . Use the following procedure to calibrate the meter . Envir on ment a l C ondi t ion 1. Perform calibration at an ambient temperature and relative humidity (23°C±2°C a nd R.H. 80%). Allow the instrument to sit at this te mperature for at ...

  • Milwaukee 2216-20 - page 20

    18 (E) DCA Calibration (V R7) 1. Rotate the rotary switch to DCA Function. 2. Connect the output of a DCA calibrator to V and COM input terminals of the meter. 3. Output DCA 5.000A from the calibrator. 4. Adjust VR7 until the display shows 5.000A ± 0.001A. 5. Turn off the output of the calibrator an d disconnect the meter from the calib rator. (F) ...

メーカー Milwaukee カテゴリー Home Safety Product

Milwaukee 2216-20のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2216-20の取扱説明書
- Milwaukeeの製品カード
- パンフレット
- またはMilwaukee 2216-20の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Milwaukee 2216-20の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Milwaukee 2216-20の取り付け説明書、サービスマニュアル、簡易説明書、またはMilwaukee 2216-20のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Milwaukee 2216-20の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Milwaukee 2216-20デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMilwaukee 2216-20を使用するのを助ける技術的文書のことです。説明書は通常、全てのMilwaukee 2216-20ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Milwaukeeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Milwaukee 2216-20の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMilwaukee 2216-20の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Milwaukee 2216-20に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Milwaukee 2216-20デバイスの基本機能を使うにあたってのヒント。 Milwaukee 2216-20のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Milwaukee 2216-20に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMilwaukee 2216-20のメーカー/サービスへの連絡先に関する情報。

Milwaukee 2216-20についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMilwaukee 2216-20の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMilwaukee 2216-20で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)