Omega Engineering LVCN700 Seriesの取扱説明書

10ページ 0.37 mb
ダウンロード

ページに移動 of 10

Summary
  • Omega Engineering LVCN700 Series - page 1

    http://www .omega.com e-mail: info@omega.com ® U ser’s Guide L VCN700 S er i es Multi-Point Ultrasonic Level Switch WARRANTY /DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OM EGA Warranty adds an additional one (1) month grace period to th ...

  • Omega Engineering LVCN700 Series - page 2

    Step One SPECIFICA TIONS Range: L VCN704: 2" to 4' (5 cm to 1.2m) L VCN709: 4" to 9.8' (10 cm to 3m) L VCN716: 4" to 16.4' (10 cm to 5m) L VCN126: 8" to 26.2' (20 cm to 8m) Repeatability: 0.25" (6 mm) Adjustability: Over entire range Hysteresis: L VCN704/709: 0.5" (1.2 cm) (single set point) L VCN71 ...

  • Omega Engineering LVCN700 Series - page 3

    INTR ODUCTION TECHNOLOGY Step Three A. Application: The general purpose ultrasonic level switch pro- vides non-contact level detection up to 26’ or 8m with 3 relays. Each relay can be configured on a single set point alarm, two latched set points for automatic fill or empty , two set points for out of bounds alarms or three set point (relays 1 an ...

  • Omega Engineering LVCN700 Series - page 4

    Step Four Step Five CALIBRA TION A. Introduction: The switch has two modes, the RUN and CAL modes. In the RUN mode, the switch is operational and the relay(s) will energize or de-ener gize at the calibrated set point distances. In the CAL mode, the relay set point distances and states may be target-cal- ibrated into memory . The switch arrives from ...

  • Omega Engineering LVCN700 Series - page 5

    Step Seven Step Six CALIBRA TION B. Calibration T ools: T o target calibrate the switch set points, you will need the appropriate power supply (95-250 V AC or 12-28 VDC for DC version), tape measurer , flat reflective target such as a wall, and optional Omega box insert for use as a product holder . C. Off T ank T arget Calibration: The switch’ s ...

  • Omega Engineering LVCN700 Series - page 6

    Step Eight PR OGRAMMING Step Nine PR OGRAMMING C. Programming a High and Low Level Out of Bounds Alarm: After having powered the switch with the appropriate supply voltage, entered the CAL mode, selected a relay channel and erased any previously input set points, follow the below procedure: 1. Stretch the tape measurer out to the appropriate distan ...

  • Omega Engineering LVCN700 Series - page 7

    Step T en PR OGRAMMING E. Programming A utomatic Empty: After having powered the switch with the appropriate supply voltage, entered the CAL mode, selected a relay channel and erased any previously input set points, follow the below procedure: 1. Stretch the tape measurer out to the appropriate distance in between the switch and target. 2. Position ...

  • Omega Engineering LVCN700 Series - page 8

    A. Fitting Selection: Check the switch part number to determine the required fitting mount size and thread type. The switch is commonly installed in tank adapters, flanges, brackets or stand pipes. 1. Adapter : Select a tank adapter fitting with minimal height so as to ensure that the installed transducer will not be substantially elevated into the ...

  • Omega Engineering LVCN700 Series - page 9

    Step Fourteen High Alarm VA C INPUT HOT NEUTRAL Motor Starter (Pump) RELA Y 1 RELA Y 2 RELA Y 3 L 1 L 2 POWER VA C Cal. Run High Low Select Low Alarm VA C INPUT NEUTRAL HOT High Alarm VDC INPUT HOT NEUTRAL Motor Starter (Pump) RELA Y 1 RELA Y 2 RELA Y 3 (+) (-) POWER VDC Cal. Run High Low Select Low Alarm VDC INPUT NEUTRAL HOT WIRING Step Fifteen T ...

  • Omega Engineering LVCN700 Series - page 10

    Relay 1 Relay 2 Energize De-Energize Energize De-Energize Backup Primary Stop Relay 1 Relay 2 Energize De-Energize Energize De-Energize Backup Primary Stop Duplexing Control Operation Alternating Control Operation OPERA TION Step Sixteen Relay X Energize De-Energize Start Stop A utomatic Empty Operation A utomatic Fill Operation Out of Bounds Opera ...

メーカー Omega Engineering カテゴリー Switch

Omega Engineering LVCN700 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LVCN700 Seriesの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering LVCN700 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering LVCN700 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering LVCN700 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering LVCN700 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering LVCN700 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering LVCN700 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering LVCN700 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering LVCN700 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering LVCN700 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering LVCN700 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering LVCN700 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering LVCN700 Seriesデバイスの基本機能を使うにあたってのヒント。 Omega Engineering LVCN700 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering LVCN700 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering LVCN700 Seriesのメーカー/サービスへの連絡先に関する情報。

Omega Engineering LVCN700 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering LVCN700 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering LVCN700 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)