Bryant TSTATの取扱説明書

16ページ 0.13 mb
ダウンロード

ページに移動 of 16

Summary
  • Bryant TSTAT - page 1

    NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. INDEX Page SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION ..........................................................................1 INSTALLATION CONSIDERATIONS ............. ...

  • Bryant TSTAT - page 2

    • Close to or in a frequently used room, preferably on an inside partitioning wall. • On a section of wall without pipes or duct work. Thermostat should NOT be mounted: • Close to a window, on an outside wall, or next to a door leading to the outside. • Exposed to direct light and heat from a lamp, sun, fireplace, or other temperature-radia ...

  • Bryant TSTAT - page 3

    On power up, all display segments will light for 5 sec. For the next 5 sec, a 2-digit code appears on large display which identifies thermostat configuration: 1. AC—for 1-speed air conditioner 2. HP—for 1-speed heat pump 3. A2—for 2-speed air conditioner 4. H2—for 2-speed heat pump 5. HS—for intelligent heat staging with FK, FV Fan Coil a ...

  • Bryant TSTAT - page 4

    1. Enter configuration mode if not already there. See above. Use up and down buttons to make small (now flashing) display indicate 03. 2. Press SET TIME/TEMP button once to flash current selection of F or C. Factory default is F. 3. Use up and down buttons to move between F and C on large display. 4. Press SET TIME/TEMP button again to flash upper ...

  • Bryant TSTAT - page 5

    TO TEST HEATING: Press MODE button until HEAT icon under it turns on. Press up button until HEAT set point (LOWER right 2 digit display with HEAT now flashing under it) is 2° or 3° (not more) above room temperature. This will create a Heat Stage 1 demand. A small triangle to the left of this HEAT icon will flash or come on continually. Flashing m ...

  • Bryant TSTAT - page 6

    → TABLE 2—PROGRAMMABLE THERMOSTAT QUICK REFERENCE THERMOSTAT OUTPUT TSTAT Model Outdoor Unit AC/HP Configuration (Switch C) Staging Configuration (Switch D) 24v Hot Common Fan Heat Stage 1 Heat Stage 2 Heat Stage 3 Heat Stage 4 Cool Stage 1 Cool Stage 2 Reversing Valve AC01-B AC EITHER EITHER R C G W/W1 N/A N/A N/A Y/Y2 N/A N/A HP01-B HP OFF EI ...

  • Bryant TSTAT - page 7

    → Fig. 2—Single-Speed Air Conditioner with Single- Stage Furnace—Model AC Thermostat A98485 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 N/A N/A R G W/W1 Y/Y2 O/W2 Y1/W2 R G W Y 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL AC THERMOSTAT SINGLE-STAGE FURNACE SINGLE-SPEED AIR CONDITIONER See note 1 SUGGESTED DIP SWITCH SETTINGS O ...

  • Bryant TSTAT - page 8

    → Fig. 7—Single-Speed Heat Pump with Typical Fan Coil—Model HP Thermostat A98490 24 VAC HOT FA N RVS COOLING COOL /HEAT STAGE 1 HEAT STAGE 2 N/ A R G W/W1 Y/Y2 O/W2 Y1/W2 R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL HP THERMOSTAT TYPICAL FAN COIL SINGLE-SPEED HEAT PUMP See notes 3, 7, and 8 Y W2 * W3 E R O W2 SUGGESTED ...

  • Bryant TSTAT - page 9

    → Fig. 11—Two-Speed Heat Pump with Single-Stage Furnace —Model 2S Thermostat A98494 COOL/HEAT STAGE 1 RVS COOLING HEAT STAGE 3 COOL/HEAT STAGE 2 FAN 24 VAC HOT R W/W1 Y/Y2 O/W2 Y1/W2 G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y Y2 C W2 MODEL 2S THERMOSTAT SINGLE-STAGE FURNACE TWO-SPEED HEAT PUMP See notes 3, 9, and 11 R Y1 O R W3 ...

  • Bryant TSTAT - page 10

    → Fig. 15—Single-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV) —Model AC Thermostat A98498 24 VAC HOT HEAT STAGE 1 N/A FAN N/A COOL STAGE 1 R R 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C G G C MODEL AC THERMOSTAT EASY SELECT TERMINAL BOARD J1 JUMPER J2 JUMPER SINGLE-SPEED AIR CONDITIONER See notes 1 and 8 DH Y1 O Y1/W ...

  • Bryant TSTAT - page 11

    → Fig. 19—Single-Speed Packaged Air Conditioner with Single-Stage Gas Furnace (588A, 589A) A98502 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 N/A N/A R G W/W1 Y/Y2 Y1/W2 O/W2 B S1 S2 MODEL AC THERMOSTAT RED GRN WHT YEL BRN See notes 1 and 11 C 24 VAC COMM N/A SPLICE BOX SUGGESTED DIP SWITCH SETTINGS ON ABC D OUTDOOR SENSOR CONNECTION → Fig. 17? ...

  • Bryant TSTAT - page 12

    → Fig. 23—Single-Speed Packaged Heat Pump with 2-Stage Electric Heat (665A, 657A, 664A) A98506 R G Y/Y2 Y1/W2 B S1 S2 MODEL HP THERMOSTAT SPLICE BOX VIO ORN WHT RED (TRAN) BRN WHT BRN See notes 3, 10, 11, and 12 C O/W2 W/W1 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION HEATER CONTROL BOX YEL GRN RED RED PNK HEAT STAGE 2 COOL/HEAT STAGE 1 RVS COOLIN ...

  • Bryant TSTAT - page 13

    → WIRING DIAGRAM NOTES 1. The AC model thermostat can only control 1-stage cool and 1-stage heat. Dip Switch-C on has no controlling function and can either be ON or OFF. 2. HP and 2S model thermostat MUST have Dip Switch-C ON when installed in air conditioner applications. If required, second-stage heat is controlled by O/W2. Refer to indoor equ ...

  • Bryant TSTAT - page 14

    → OPERATIONAL INFORMATION FIVE-MINUTE COMPRESSOR TIMEGUARD This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and the INCREASE TEMPERATURE button. FIFTEEN-MINUTE CYCLE TIMER This timer prevents the start of a heating or cooli ...

  • Bryant TSTAT - page 15

    A98508 PROGRAMMABLE THERMOSTAT CONFIGURATION RECORD Date Owner/Operator A) Hardware Configuration  Switch A Zoning Selection. (OFF = Disable, ON = Enable)  Switch B Smart Recovery. (OFF = Enable, ON = Disable)  Switch C Heat Pump Operation. (OFF = Enable, ON = Disable)  Switch D Intelligent Heat Staging. (OFF = D ...

  • Bryant TSTAT - page 16

    SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, us ...

メーカー Bryant カテゴリー Thermostat

Bryant TSTATのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TSTATの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant TSTATの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant TSTATの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant TSTATの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant TSTATのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant TSTATの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant TSTATデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant TSTATを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant TSTATユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant TSTATの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant TSTATの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant TSTATに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant TSTATデバイスの基本機能を使うにあたってのヒント。 Bryant TSTATのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant TSTATに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant TSTATのメーカー/サービスへの連絡先に関する情報。

Bryant TSTATについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant TSTATの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant TSTATで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください