Intel SC450NXの取扱説明書

24ページ 0.16 mb
ダウンロード

ページに移動 of 24

Summary
  • Intel SC450NX - page 1

    SC450NX MP Server Rack/Pedestal Kit Installation Guide Order Number: 711917-001a ...

  • Intel SC450NX - page 2

    Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document. Intel makes no commitment to update nor to keep current the information ...

  • Intel SC450NX - page 3

    Copyright  1998, Intel Corporation. All Rights Reserved. ...

  • Intel SC450NX - page 4

    ...

  • Intel SC450NX - page 5

    v Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server. • Turn off all peripheral devices connected to the server. • Turn off the server using the push-button on/off power switch on the front panel of the server, and unplug the AC power cord fro ...

  • Intel SC450NX - page 6

    vi CAUTIONS E LECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION : ESD can damage disk drives, add-in boards, and other components. This server can withstand normal levels of environmental ESD while hot -swapping SCSI hard disk drives. However, we recommend doing all procedures in this manual only at an ESD-protected workstation. If one is not availab ...

  • Intel SC450NX - page 7

    vii Equipment Rack Precautions WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of any o ...

  • Intel SC450NX - page 8

    viii ...

  • Intel SC450NX - page 9

    ix Contents Safety Guidelines Server Precautions ............................................................................................................... v Equipment Rack Precautions .............................................................................................. vii Introduction Tools You Need ................................. ...

  • Intel SC450NX - page 10

    x ...

  • Intel SC450NX - page 11

    11 Introduction The SC450NX MP server is designed to either stand upright (pedestal mode) or be mounted in a rack (rack mode). Figures 1 and 2 on page 12 show examples of these configurations. Before operation, you must purchase an adapter kit to configure the server for one of the two modes. If you have already created a pedestal server but now wa ...

  • Intel SC450NX - page 12

    12 Table 1 . SC450NX MP Server Physical Specifications Specification Pedestal Mode Rack Mode Height 48.26 cm (19 inches) 7u Width 31.12cm (12.25 inches) 19 inch rack Depth 63.5cm (25 inches) 25 inches Weight 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum configuration 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum ...

  • Intel SC450NX - page 13

    13 Configuring for Rack Mount Before starting, please read “ Safety Guidelines ” on page v . Prepare the Slide Assemblies See Figure 3 . 1. Remove the slide assemblies from the kit. 2. Orient a slide assembly so that the smallest outer bar is facing down. 3. Fully extend the telescoping slide assembly until the center bar hits the safety latch ...

  • Intel SC450NX - page 14

    14 Prepare the Server Before you can install the server in the 19-inch equipment rack, you must install a bezel, handles, and the small bars of the slide assemblies onto the sides of the server. Attaching the Bezel Frame and Door To be installed in a rack, the server needs a bezel frame with rectangular cutouts where the chassis handles fit. 1. Att ...

  • Intel SC450NX - page 15

    15 Attach the Small Bar of the Slide Assembly to the Server See Figure 4 . 1. Remove four screws from the kit. 2. While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server. 3. Align the first hole in the right-angle end of the bar with the first threaded hole ...

  • Intel SC450NX - page 16

    16 Prepare the Equipment Rack Before you can install the server in the 19-inch equipment rack, you must attach the center bar and large outer bar assemblies to the vertical rails of the rack. Attach the Right-angle Extension Brackets to the Equipment Rack / NOTE Mounting holes in the vertical rails of equipment racks are commonly spaced in a 5/8 x ...

  • Intel SC450NX - page 17

    17 Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack See Figure 6 . 1. Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack. 2. Press the flat side of the outer bar into the U -s ...

  • Intel SC450NX - page 18

    18 Install the Server in the Rack WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of an ...

  • Intel SC450NX - page 19

    19 1 Small outer bar 2 Center bar 3 Large outer bar 4 Safety latch Figure 7 . Installing the Server in the Rack ...

  • Intel SC450NX - page 20

    20 ...

  • Intel SC450NX - page 21

    21 Configuring for Pedestal Mount Install Chassis Feet See Figure 8 . 1. Remove two system feet and two screws from the kit. 2. Each system foot has one screw hole and, on the opposite end, two slots that fit two tabs extending from the chassis wall. Orient the chassis foot to align these features with their corresponding parts of the chassis wall. ...

  • Intel SC450NX - page 22

    22 Install Bezel Frame and Door 1. Attach the bezel frame by inserting the tabs at the corner of the frame into their corresponding rectangular slots on the chassis. 2. Attach the bezel door: with the door all the way open (left, as it stands upright in a pedestal mount), align the tabs on the door with their corresponding hinge loops on the chassi ...

  • Intel SC450NX - page 23

    23 Changing from Pedestal to Rack To change your server from pedestal mode to rack mode, you must complete two basic steps: removing the components of the pedestal mount, then configuring the server for a rack mount. Because configuring for a rack mount was described in an earlier section (page 13 ), this section covers only a few details unique to ...

  • Intel SC450NX - page 24

    24 Exchange the Bezel Frame To be installed in a rack, the server needs a new bezel frame with rectangular cutouts where the chassis handles fit. You need to remove the old bezel frame and install the new one from the rack kit. 1. Remove the bezel door: with the door open all the way (to the left), lift it upward to release it from its hinges on th ...

メーカー Intel カテゴリー Life Jacket

Intel SC450NXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SC450NXの取扱説明書
- Intelの製品カード
- パンフレット
- またはIntel SC450NXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Intel SC450NXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Intel SC450NXの取り付け説明書、サービスマニュアル、簡易説明書、またはIntel SC450NXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Intel SC450NXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Intel SC450NXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIntel SC450NXを使用するのを助ける技術的文書のことです。説明書は通常、全てのIntel SC450NXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Intelの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Intel SC450NXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIntel SC450NXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Intel SC450NXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Intel SC450NXデバイスの基本機能を使うにあたってのヒント。 Intel SC450NXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Intel SC450NXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIntel SC450NXのメーカー/サービスへの連絡先に関する情報。

Intel SC450NXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIntel SC450NXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIntel SC450NXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)