    1 WARNINGS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. ...

  • United States Stove VF30IL - page 2

    2 TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION.............................................................3-4 PRODUCT FEATURES...........................................................................................4 SPECIFICATIONS......................................................................................................5 CONTENTS.. ...

  • United States Stove VF30IL - page 3

    3 CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly. The installation must conform with local codes or, in the absence of local codes, with the National ...

  • United States Stove VF30IL - page 4

    4 IMPORTANT SAFETY INFORMATION Outside air ducts in the fireplace shall be permanently closed at the time of appliance installation. Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Fireplace screen must be closed during operation of the heater. This vent-free gas heater is intended to ...

  • United States Stove VF30IL - page 5

    5 SPECIFICATIONS Natural Gas Manifold Pressure Setting 4" w.c. Gas Inlet Pressure Maximum 10-1/2" w.c. Minimum 5" w.c. Gas Rate Number Model Number Type Max BTU/Hr Min BTU/Hr of Burners VF30IN Manual 30,000 16,000 1 Propane / LPG Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. Manifold ...

  • United States Stove VF30IL - page 6

    6 UNIT DIMENSIONS MINIMUM AND MAXIMUM SIZE OF FIREPLACE DI ME N S I ON MI NI MU M MA X I MU M A 26" 44" B 22- 1/ 4" 32" C 13- 1/ 4" 24" ...

  • United States Stove VF30IL - page 7

    7 ITEMS REQUIRED FOR INSTALLATION ITEMS REQUIRED FOR INSTALLATION Ensure that the following items are available before proceeding with installation: • External regulator (for propane/LPG only) • Manual shutoff valve • Piping which complies with local codes • Sediment trap • Pipe sealant approved for use with • Pipe wrench propane/LPG (r ...

  • United States Stove VF30IL - page 8

    8 Providing adequate ventilation The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction; 2. Unconfined Space; 3. Confined Space. The information on pages 7 throug ...

  • United States Stove VF30IL - page 9

    9 Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install the firebox plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height) ...

  • United States Stove VF30IL - page 10

    10 B. Vent room directly to the outdoors. See Ventilation Air from Outdoors , page 11. C. Install a lower BTU/Hr firebox, if lower BTU/Hr size makes room unconfined. If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation. WARNING If the are ...

  • United States Stove VF30IL - page 11

    11 WARNING Maintain these clearances to ensure adequate space around air opening for proper operation. Minimum clearances to combustibles: Sides of heater...........................8" MIN Front of heater.........................60" MIN Top of heater............................50" MIN Top to Mantel...........................18" M ...

  • United States Stove VF30IL - page 12

    12 INSTALLING TOP SURROUND & BRASS TRIM INSTALLING TOP SURROUND N OTE : YOU WILL NEED A FLATHEAD SCREW - DRIVER AND A 3/8" NUT - DRIVER TO ATTACH THE SURROUND AND BRASS TRIM . The top surround is shipped unassembled for shipping purposes only. To install the top surround place the surround on top of the unit and line up the holes. Attach t ...

  • United States Stove VF30IL - page 13

    13 PREPARING FIREPLACE WARNING: IF THIS APPLIANCE IS INSTALLED IN A FACTORY-BUILT FIREPLACE, DO NOT BLOCK OR RESTRICT ANY OF THE GRILLES ON THE FACTORY-BUILT FIREPLACE. THE GRILLES ALLOW AIR CIRCULATION WHICH PREVENTS THE FACTORY-BUILT FIREPLACE FROM OVERHEATING. BLOCKING OR RESTRICTING THE AIR CIRCULATION CAN CAUSE A FIRE HAZARD. Preparing Firepla ...

  • United States Stove VF30IL - page 14

    14 GAS CONNECTION A qualified gas appliance installer must connect the fireplace to the gas supply. Consult all local codes. Use new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas volume to heater. Excessive pres ...

  • United States Stove VF30IL - page 15

    15 The heater regulator controls the burner pressure which should be checked at the pressure test point located on the right side of the main control and is accessible from the side of the gas log assembly (see FIGURE 6). The pressure should be checked with the heater burning and the control set to high (HI). The pressure regulator is preset and lo ...

  • United States Stove VF30IL - page 16

    16 WIRING BLOWER ASSEMBLY To locate the blower, open the lower access door and locate the blower cover as shown in FIGURE 7. The blower is located directly behind the blower cover. The blower comes partially pre-wired into the junction box. To complete wiring, run the house power supply into the heater through one of the knockouts located on either ...

  • United States Stove VF30IL - page 17

    17 LOGS AND LOG STOP ASSEMBLY LOG POSITIONING This unit is supplied with a set of four ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers. PROPER INSTALLATION SEQUENCE: 1. ...

  • United States Stove VF30IL - page 18

    18 OPERATING INSTRUCTIONS Avoid any drafts that alter the burner flame patterns. Do not allow fans to blow directly into the heater. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur. This unvented gas heater is intended to be smokeless. If log ...

  • United States Stove VF30IL - page 19

    19 6. Push in the control (knob 1) all the way and rotate counter-clockwise to "PILOT". The piezo ignitor will light the pilot as the knob passes "IGN" traveling to the "PILOT". Con tinue to hold the control (knob 1) in for about ten (10) seconds after the pilot is lit. Release knob and it should pop back up. Pilot sho ...

  • United States Stove VF30IL - page 20

    20 OPERATING INSTRUCTIONS Wait 30 seconds before readjusting the heater when the control has been turned down to a lower setting. WARNING PILOT FLAME The pilot flame should always be present when the heater is in operation and should just touch the top of the thermocouple tip (FIGURE 9). If the pilot flame does not touch the thermocouple, then the ...

  • United States Stove VF30IL - page 21

    21 CLEANING / SERVICING Periodic Cleaning • Do not use cleaning fluid to clean logs or any part of heater. • Logs - Brush with soft bristle brush or vacuum with brush attachment. • Vacuum loose particles and dust from the front and rear burner, control, and piezo. • Inspect burner's and air intake hole. Remove lint or particles with va ...

  • United States Stove VF30IL - page 22

    22 HEATER ASSEMBLY REPLACEMENT PARTS ...

  • United States Stove VF30IL - page 23

    23 PARTS LIST FOR HEATER ASSEMBLY KEY PART # DESCRIPTION QTY. 1 24731 CABINET BOTTOM 1 2 24732 FIREBOX 1 3 24733 FIREBOX BOTTOM 1 4 24734 INNER TOP 1 5 24735 OUTER TOP 1 6 69184 BLOWER CHANNEL 1 7 24738 DIVIDER 1 8 80337 120 CRM BLOWER 1 9 24759 BLOWER BASE 1 10 24761 BLOWER COVER 1 N/S 89390A 3/8" RUBBER GROMMET 1 11 24739 FRONT BRACE 1 12 24 ...

  • United States Stove VF30IL - page 24

    24 BURNER & LOG ASSEMBLY ...

  • United States Stove VF30IL - page 25

    25 PARTS LIST FOR GAS LOG ASSEMBLY KE Y PA R T # D ESC R I PT I ON QT Y . 1 24751 B URNE R P L A T E 1 2 24752 C O N T R O L BR AC KET 1 3 81195 CO NT RO L V A L V E ( NA T URA L ) 1 81196 CO NT RO L V A L V E ( L. P. ) 1 4 83251 10- 24 x 1 SL RO D 2 5 83244 10- 2 4 KEP N U T 2 6 89831 BU R N ER / CO NT RO L FI TTI NG 1 7 24754 PI L O T BR AC KET 1 ...

  • United States Stove VF30IL - page 26

    26 TROUBLESHOOTING Turn off and let cool before servicing. Only a qualified service person should service and repair heater. NOTE: All troubleshooting items are listed in order of operation. REMEDY POSSIBLE CAUSE OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/Pilot. • Ignitor electrode positioned wrong • Ignitor elect ...

  • United States Stove VF30IL - page 27

    27 TROUBLESHOOTING, CONTINUED... ODS/Pilot lights, but flame goes out When control knob is released. (continued from page 25) One or both burner do not light after ODS/pilot is lit. Burner backfires during combustion. Slight smoke or odor during initial operation. Logs appear to smoke after initial operation. Heater produces a whistling noise when ...

  • United States Stove VF30IL - page 28

    28 OWNERS MANUAL HOW TO ORDER REPAIR PARTS OR "OPTIONS" UNITED STATES STOVE COMPANY 227 Industrial Park Rd., P.O. Box 151 South Pittsburg, TN 37380 (423) 837-2100 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U BEFORE INSTALLING YOUR HEATER, FILL IN THE SERIAL NUMBER IN THE SPACE PROVIDED ABOVE FOR YOUR RECORDS. 1. The PART NUMBER ...

メーカー United States Stove カテゴリー Gas Heater

United States Stove VF30ILのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VF30ILの取扱説明書
- United States Stoveの製品カード
- パンフレット
- またはUnited States Stove VF30ILの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、United States Stove VF30ILの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、United States Stove VF30ILの取り付け説明書、サービスマニュアル、簡易説明書、またはUnited States Stove VF30ILのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、United States Stove VF30ILの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

United States Stove VF30ILデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnited States Stove VF30ILを使用するのを助ける技術的文書のことです。説明書は通常、全てのUnited States Stove VF30ILユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

United States Stoveの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. United States Stove VF30ILの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnited States Stove VF30ILの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。United States Stove VF30ILに関してこのドキュメントで見つけることができる全てのヒントの目次
3. United States Stove VF30ILデバイスの基本機能を使うにあたってのヒント。 United States Stove VF30ILのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。United States Stove VF30ILに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnited States Stove VF30ILのメーカー/サービスへの連絡先に関する情報。

United States Stove VF30ILについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnited States Stove VF30ILの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnited States Stove VF30ILで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)