N-Tron 100 Seriesの取扱説明書

18ページ 0.65 mb
ダウンロード

ページに移動 of 18

Summary
  • N-Tron 100 Series - page 1

    5/17/2007 1 100 Serie s Media Conve rter & Industri al Ethernet Switche s User Manual & Install ation Guide ...

  • N-Tron 100 Series - page 2

    5/17/2007 2 Industrial Medi a Converter Installation Guide 102MC-XX 102MCE-XX-YY 104TX 105TX 108TX Where: XX = ST or SC a nd YY = -15, -40, or -80 ...

  • N-Tron 100 Series - page 3

    5/17/2007 3 Copyright, © N-TRON Corp., 2 007 820 S. Universit y Blvd., Suite 4E Mobile, AL USA 36609 All rights reserved. Repr oduction, adaptation, or translation without prior written permission from N-TRON Corp. is prohibited, ex cept as allowed under cop yright laws. Ethernet is a registered trademark of Xerox Corporation. All other product na ...

  • N-Tron 100 Series - page 4

    5/17/2007 4 GENERAL SAFETY WARNIN GS WARNING: Do not operate the equipment i n the presen ce o f flamm able gasses or fumes. Operating electrical equipment in such an environment constit utes a definite safety hazard. WARNING: If the equi pment is used in the manner not specified b y N-TRON Corp., t he protection provided by the equipment ma y be i ...

  • N-Tron 100 Series - page 5

    5/17/2007 5 HAZARDOUS LOCAT ION INSTAL LATION REQUIREMENTS 1. This equipment is suitable for use in Class I, Di v 2, Groups A, B, C, and D, or uncl assified or non- hazardous locations. 2. WARNING: Explos ion Hazard - Substitut ion of components may impair suitabilit y for Class I, Division 2. 3. WARNING: Explosion hazard, do not disconnect while t ...

  • N-Tron 100 Series - page 6

    5/17/2007 6 100 Series Indus trial Ethernet Switches The 100 Series Unmana ged Industrial Ethernet Swit ches support high speed la yer 2 switching between ports. This series of swit ches are housed in a ru ggedized aluminum enclosure, and provid e Categor y-5 compliant 10/100-BaseT connections for high perform ance network design, and hub/repe ater ...

  • N-Tron 100 Series - page 7

    5/17/2007 7 PACKAGE CONTENT S Please make sure the Serial ov er Ethernet package contains the foll owing items: 1. 100 Series Media Converter or Ethern et Switch 2. Instruction Sheet Contact your carrier if an y items are damaged. UNPACKING Remove all the equipment from the packaging, and s tore the packaging in a safe place. File an y damage claim ...

  • N-Tron 100 Series - page 8

    5/17/2007 8 DIN-Rail Mounting Install the unit in a standard D IN rail. Recess the uni t to allow at least 2” of horizont al clearance for CAT5e cable bend radius. To inst all the unit to 35mm ind ustrial D I N rail, place the top ed ge of the includ ed mounting bracket on the back of the unit against the D IN rail at a 15° angle as sho wn. Rota ...

  • N-Tron 100 Series - page 9

    5/17/2007 9 FRONT PANEL 102MC/MCE From Top to Bottom: SPD Speed LED LNK/ACT Link/Activity LED RJ45 Ports Auto sensing 10/100 BaseT Connection Green LED lights when Power is connected NOTE: The RJ 45 data port has two LED’s located at the left side of t he connector. The top LED indi cates Activity (ACT), and the l ower LED indicates Link (LNK) st ...

  • N-Tron 100 Series - page 10

    5/17/2007 10 APPLYING POWER (To p View) Unscrew & Remove the DC Voltage Input Plug fr om the top header. Install the DC Power Ca bles into the Plug (observing polarit y on unit). Plug the Voltage Input Pl ug back into the top header. Tightening torque for the termin al block power plug is 0.22 N m/0.162 Pound Foot . All LED’s will flash ON Mo ...

  • N-Tron 100 Series - page 11

    5/17/2007 11 N-TRON SWITCH GR OUNDING TECHNIQ UES FOR 100 SERIE S The grounding phil osophy of an y control s ystem is an integral part of the design. N-Tron s witches are designed to be grounded, but the user has been given the flexibilit y to float the switch when required. The best noise immunit y and emissi ons (i.e. CE) are obtained when the N ...

  • N-Tron 100 Series - page 12

    5/17/2007 12 CONNECTING THE UNIT For th e 100 BaseFX Fiber Optic port, remove th e dust cap(s) fr om the fiber optic connector and connect the fiber optic cables. The T X port on the l ocal unit should be connected to the RX port of the far end device, and the RX port should be co nnected to the TX port of the far end device. For 10Base-T ports, pl ...

  • N-Tron 100 Series - page 13

    5/17/2007 13 FCC STATEMENT This product complies with P art 15 of the FCC-A Rules. Operation is subject to the following condi tions: (1) This device ma y not cause harmful Interference (2) This device m ust accept an y interference r eceived, including inter ference that may cause undesired operation. NOTE: This equipment has been tested and found ...

  • N-Tron 100 Series - page 14

    5/17/2007 14 Regulatory Approvals: Safety: UL Listed per ANS I/ISA-12.12.01-2000 (US and C anada) This apparatus is suitable for use in Class I, Div 2, Groups A, B, C, an d D UL Temperature Ratings: 102MC/MC E - T5 104TX, 105TX, and 108TX - T4A EMI: EN61000-6-4, EN55011 - Class A FCC Title 47, Part 15, S ubpart B - Class A ICES-003 – Class A EMS: ...

  • N-Tron 100 Series - page 15

    5/17/2007 15 102MC/MCE - KEY SPECI FICATIONS Physical Height: 2.90” (max.) Width: 1.50” (max. ) Depth Including Din-Rail Clip: 4.82” (max.) Weight: 0.60 lbs. Electrical Input Voltage: 10-30 VDC (Regulated ) Input Current: 1 40mA max. @ 24VDC (Steady State) Inrush Current: 8.5Amp/0.7 ms max . @ 24VDC Input Ripple: Less than 100 mV Input Wire S ...

  • N-Tron 100 Series - page 16

    5/17/2007 16 104TX/105TX - KEY SPECI FICATIONS Physical Height: 2.9” (max.) Width: 1.50” (max. ) Depth: 4.25” (max.) Weight: 0.60 lbs. Electrical Input Voltage: 10-30 VDC (Regulated ) Input Current: 215 mA max. @ 2 4VDC (Steady State) Inrush Current: 7.8 Amp/0.7ms m ax. @ 24VDC Input Ripple: Less than 100 mV Input Wire Size: 16-28 AW G Enviro ...

  • N-Tron 100 Series - page 17

    5/17/2007 17 108TX - KEY SPECI FICATIONS Physical Height: 3.5” (8.89 cm) Width: 1.50” (3.81 cm) Depth Including DIN Rail Cli p: 4.22” (10.7 cm) Weight: 0.64 lbs. (0.29 kg) DIN Rail 35 mm Electrical Input Voltage: 10-30 VDC (Regulated) Input Current: 250 mA max. @ 2 4VDC (Steady State) Inrush Current: 8.1 Amp/0.7ms max . @ 24VDC Input Ripple: ...

  • N-Tron 100 Series - page 18

    5/17/2007 18 N-TRON Limited Warrant y N-TRON, Co rp. warrants to the end u ser t hat this hardware pro duct will b e free from defects in workmanship and materials, und er nor mal use and service, for the ap plicable warranty perio d from th e date of purchase from N- TRON o r it s autho rized r eseller. If a produ ct does not o perate as warranted ...

メーカー N-Tron カテゴリー Switch

N-Tron 100 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 100 Seriesの取扱説明書
- N-Tronの製品カード
- パンフレット
- またはN-Tron 100 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、N-Tron 100 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、N-Tron 100 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはN-Tron 100 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、N-Tron 100 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

N-Tron 100 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがN-Tron 100 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのN-Tron 100 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

N-Tronの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. N-Tron 100 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははN-Tron 100 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。N-Tron 100 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. N-Tron 100 Seriesデバイスの基本機能を使うにあたってのヒント。 N-Tron 100 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。N-Tron 100 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるN-Tron 100 Seriesのメーカー/サービスへの連絡先に関する情報。

N-Tron 100 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもN-Tron 100 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがN-Tron 100 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)