Scytek electronic 1000RS-DBPの取扱説明書

32ページ 0.35 mb
ダウンロード

ページに移動 of 32

Summary
  • Scytek electronic 1000RS-DBP - page 1

    ASTRA 4000RS/1000RS-DBP G55 SERIES VEHICLE SECURITY SYSTEM WITH REMOTE START PRODUCT MANUAL ...

  • Scytek electronic 1000RS-DBP - page 2

    L i m i t e d L i f e t i m e W a r r a n t y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will rep air or replace at its option, and free of charge for the first twelve (12) months, any part that proves defective in material or workmanship under normal i ...

  • Scytek electronic 1000RS-DBP - page 3

    1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P age 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . . ...

  • Scytek electronic 1000RS-DBP - page 4

    The ScyT ek ASTRA is a combination vehicle securit y and remote starting system. With proper installation this system will provide superior protection and performance f or many years to come. The ASTRA/G55 built-in remote start f eature is designed to offer maximum con v enience by remote starting your vehicle’ s engine, turning on the heater/air ...

  • Scytek electronic 1000RS-DBP - page 5

    Standard Remote Transmitter Description The ASTRA/G55 comes equipped with the 5-button R emote T ransmit ters used to control system operations. Button 1 Arms the system and when held for 5 seconds, activ ates the system’ s P anic f eature. Button 1 also locks the doors when the system is in V alet Mode. Button 2 Disarms the system. Button 2 also ...

  • Scytek electronic 1000RS-DBP - page 6

    Adding/Replacing Transmitters T o replace lost or stolen tr ansmitters or to add additional transmit ters into the system, have all desired transmit ters ready and follow the steps below . Note : Up to 4 one-wa y transmitters can be progr ammed to operate the system. An y previously stored transmit ter codes will be erased if they are not progr amm ...

  • Scytek electronic 1000RS-DBP - page 7

    Page 4 - ASTRA/G55 2-way LCD Remote Transmitter Description The Astra 4000RS-2W -1 is supplied one 2-way LCD remote transmitter , offering increased r ange and confirmation of any activ ated features. Button 1 Arms the system and when held for 5 seconds, activ ates the system’ s P anic f eature. Button 1 also locks the doors when the system is in ...

  • Scytek electronic 1000RS-DBP - page 8

    ASTRA/G55 - Page 5 LCD Transmitter Battery Replacement Y our Astr a Remote T r ansmitter uses a 1.5 volt AAA alkaline battery , which will require replacement in time. Depending on the amount of use, the battery may last up to three months bef ore it needs replacement. When the battery needs replacing, the system’ s operating range will decrease, ...

  • Scytek electronic 1000RS-DBP - page 9

    Page 6 - ASTRA/G55 4. When the desired time is display ed, press Button 5 to store. · The r emote will pla y a melody to indicate the alarm clock has been set. T o disable the automatic start / auto activ ate function: 1. Press and hold Buttons 2 and 3 until the remote beeps four times. · The fan and clock will be shown indicating automatic start ...

  • Scytek electronic 1000RS-DBP - page 10

    ASTRA/G55 - Page 7 The PSV or passive function allows the passiv e arming mode to be enabled or with the transmit ter . Note: This feature may not be a vailable on all systems. T o enable or disable the passive arming mode: 1. Press and hold Button 5 until the display shows PSV . · The transmit ter wi ll beep f our times. 2. Release But ton 5. · ...

  • Scytek electronic 1000RS-DBP - page 11

    Page 8 - ASTRA/G55 Remote Arming The system monitors 5 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the S ystem: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking lights will flas ...

  • Scytek electronic 1000RS-DBP - page 12

    ASTRA/G55 - Page 9 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 8 times. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes = door 6 ...

  • Scytek electronic 1000RS-DBP - page 13

    Page 10 - ASTRA/G55 Panic Mode In the event of an emergency the tr ansmitter’s remote P anic feature can be used to instantly trigger the alarm. T o activ ate the Panic Mode: 1. Press and hold Button 1 for fiv e seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock* allowing access to the vehicle. 2. Press B ...

  • Scytek electronic 1000RS-DBP - page 14

    ASTRA/G55 - Page 11 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 6 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, press But ...

  • Scytek electronic 1000RS-DBP - page 15

    Page 12 - ASTRA/G55 Remote Starting T o R emote Start the System: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will flash 4 times and turn on. · The Siren will chirp 4 times. · The engine will start and run for the dur ation of its programmed Run Time.* · The heater or air condi ...

  • Scytek electronic 1000RS-DBP - page 16

    ASTRA/G55 - Page 13 Automatic Start Mode The Automatic Start Mode allows the vehicle to automatically start the vehicle ev ery one or two hours and run for the preset Run Time. T o turn on Auto Starting: 1. T urn Ignition switch Off and w ait for 3 seconds. 2. T urn Ignition switch On and Off three times ending with I gnition in Off position 3. Pre ...

  • Scytek electronic 1000RS-DBP - page 17

    Page 14 - ASTRA/G55 E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking f eature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disabled to prot ...

  • Scytek electronic 1000RS-DBP - page 18

    ASTRA/G55 - Page 15 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit T wo 5-Button R emote T ransmitters (4000RS) One 5-Button & One LCD T wo-W ay T ransmitter (4000RS-2W -1) Siren Shock Sensor Harnesses • 6- Wire starter harness/Relay Module ? ...

  • Scytek electronic 1000RS-DBP - page 19

    Page 16 - ASTRA/G55 Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the oper ation of any vehicle components such as f oot pedals, steering colum ...

  • Scytek electronic 1000RS-DBP - page 20

    ASTRA/G55 - Page 17 S y s t e m W i r i n g 6-Wire Starter Harness Pin 1 RED - A : Main P ower Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 30 Amp supply . R emo v e the f use until the installation is complete and all wiring is checked. Pin 2 RED - B : Main P ower Input B (+). Connect to the batt ...

  • Scytek electronic 1000RS-DBP - page 21

    Page 18 - ASTRA/G55 Pin 13 GRAY : Auxiliary 1 Output (-) 500 mA. Connect to a relay for an optional f eature such as trunk release, etc. This output may be progr ammed for momentary , timed, or latched operation. Pin 14 GREEN/WHITE : Brak e Input (+). Connect to the wire that shows +12V when pressing the brake. The Green/white wire is a safety shut ...

  • Scytek electronic 1000RS-DBP - page 22

    ASTRA/G55 - Page 19 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper f or the correct polarity output as described below , then reassemble the main unit case. Parking Light Output. Selec ...

  • Scytek electronic 1000RS-DBP - page 23

    Page 20 - ASTRA/G55 Entering System Programming The system programming is compatible with both the L CD transmitter or the standard AM tr ansmitter . T o enter S ystem Programming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide three chirps, indicating that you ha ve entered Programming. 3. Pres ...

  • Scytek electronic 1000RS-DBP - page 24

    Branch Feature Button 1 (default) Button 2 Button 3 1. Arm Mode Manual Arming P assive Arming 2. Auto Rearming Mode Disabled Enabled 3. Arming Chirps Siren Chirps On Silent Siren & Horn Chirps On 4. W arn-Away P ager Report Enabled Disabled 5. Extended P arking Lights On Off 6. Ignition Door Locking On Off Set Override Code 7 . Ignition Door Un ...

  • Scytek electronic 1000RS-DBP - page 25

    Page 22 - ASTRA/G55 locking and unlocking. Program to 3 seconds f or v ehicles equipped with v acuum door locking systems. 0.1 seconds for vehicles that roll windows up or down when lock/unlock output is at 1 second. 10. Passive Door Locking. Selects whether or not the system will automatically lock the doors during P assive Arming. 11. Ignore Open ...

  • Scytek electronic 1000RS-DBP - page 26

    ASTRA/G55 - Page 23 RPM Learn. Start the engine, enter Br anch 21 and press Button 1 to learn the v ehicle’ s tach signal. The siren will chirp and the LED will flash once to confirm learning of the tach signal and entering T ach Monitor Mode. The siren will chirp f our times and the LED will flash four times if the tach signal was not learned, e ...

  • Scytek electronic 1000RS-DBP - page 27

    ASTRA/G55 - Page 24 R e l a y D i a g r a m s P ositive Dome Light Activ ation Negative Dome Light Activ ation P ositive Horn Honk Negative Horn Honk Negative Glow Plug Starter Defeat/Anti-Grind ...

  • Scytek electronic 1000RS-DBP - page 28

    Page 25 - ASTRA/G55 Negative T rigger P ositive T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages. D o o r L o c k D i a g r a m s Green Blue ...

  • Scytek electronic 1000RS-DBP - page 29

    ASTRA/G55 - Page 26 T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negative T rigger T wo Stage P ositive T rigger(using inv erter) The ASTRA/G55 can be wired for the P assenger Unlock output feature, allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door . Pre ...

  • Scytek electronic 1000RS-DBP - page 30

    Page 27 - ASTRA/G55 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators Aux 1 output (gray wire) Aux 1 output (gray wire) ...

  • Scytek electronic 1000RS-DBP - page 31

    ASTRA/G55 - Page 28 FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interf erence that may cause undesired operation T e c h n i c a l I n f o r m a t i o n S ...

  • Scytek electronic 1000RS-DBP - page 32

    ScyTek Electronics 11627 Cantara Street North Hollywood, CA 91605 www .scytek.net © ScyT ek Electronics 2010 ASTRA/G55- 6/10/10 W i r i n g D i a g r a m Violet - Starter Out 25 Amp. (+) Red - +12V Battery Input #1 Red - +12V Battery Input #2 Brown - Ignition 2 Output 25 Amp. (+) Yellow- Ignition 1 Out 25 Amp. (+) Orange- Accessory Out 25 Amp. (+) ...

メーカー Scytek electronic カテゴリー Automobile Alarm

Scytek electronic 1000RS-DBPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1000RS-DBPの取扱説明書
- Scytek electronicの製品カード
- パンフレット
- またはScytek electronic 1000RS-DBPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Scytek electronic 1000RS-DBPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Scytek electronic 1000RS-DBPの取り付け説明書、サービスマニュアル、簡易説明書、またはScytek electronic 1000RS-DBPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Scytek electronic 1000RS-DBPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Scytek electronic 1000RS-DBPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがScytek electronic 1000RS-DBPを使用するのを助ける技術的文書のことです。説明書は通常、全てのScytek electronic 1000RS-DBPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Scytek electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Scytek electronic 1000RS-DBPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははScytek electronic 1000RS-DBPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Scytek electronic 1000RS-DBPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Scytek electronic 1000RS-DBPデバイスの基本機能を使うにあたってのヒント。 Scytek electronic 1000RS-DBPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Scytek electronic 1000RS-DBPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるScytek electronic 1000RS-DBPのメーカー/サービスへの連絡先に関する情報。

Scytek electronic 1000RS-DBPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもScytek electronic 1000RS-DBPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがScytek electronic 1000RS-DBPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

Анжела

CLOSE DRAWER