Manual Scytek electronic 1000RS-DBP

32 pages 0.35 mb
Download

Go to site of 32

Summary
  • Scytek electronic 1000RS-DBP - page 1

    ASTRA 4000RS/1000RS-DBP G55 SERIES VEHICLE SECURITY SYSTEM WITH REMOTE START PRODUCT MANUAL ...

  • Scytek electronic 1000RS-DBP - page 2

    L i m i t e d L i f e t i m e W a r r a n t y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will rep air or replace at its option, and free of charge for the first twelve (12) months, any part that proves defective in material or workmanship under normal i ...

  • Scytek electronic 1000RS-DBP - page 3

    1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P age 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . . ...

  • Scytek electronic 1000RS-DBP - page 4

    The ScyT ek ASTRA is a combination vehicle securit y and remote starting system. With proper installation this system will provide superior protection and performance f or many years to come. The ASTRA/G55 built-in remote start f eature is designed to offer maximum con v enience by remote starting your vehicle’ s engine, turning on the heater/air ...

  • Scytek electronic 1000RS-DBP - page 5

    Standard Remote Transmitter Description The ASTRA/G55 comes equipped with the 5-button R emote T ransmit ters used to control system operations. Button 1 Arms the system and when held for 5 seconds, activ ates the system’ s P anic f eature. Button 1 also locks the doors when the system is in V alet Mode. Button 2 Disarms the system. Button 2 also ...

  • Scytek electronic 1000RS-DBP - page 6

    Adding/Replacing Transmitters T o replace lost or stolen tr ansmitters or to add additional transmit ters into the system, have all desired transmit ters ready and follow the steps below . Note : Up to 4 one-wa y transmitters can be progr ammed to operate the system. An y previously stored transmit ter codes will be erased if they are not progr amm ...

  • Scytek electronic 1000RS-DBP - page 7

    Page 4 - ASTRA/G55 2-way LCD Remote Transmitter Description The Astra 4000RS-2W -1 is supplied one 2-way LCD remote transmitter , offering increased r ange and confirmation of any activ ated features. Button 1 Arms the system and when held for 5 seconds, activ ates the system’ s P anic f eature. Button 1 also locks the doors when the system is in ...

  • Scytek electronic 1000RS-DBP - page 8

    ASTRA/G55 - Page 5 LCD Transmitter Battery Replacement Y our Astr a Remote T r ansmitter uses a 1.5 volt AAA alkaline battery , which will require replacement in time. Depending on the amount of use, the battery may last up to three months bef ore it needs replacement. When the battery needs replacing, the system’ s operating range will decrease, ...

  • Scytek electronic 1000RS-DBP - page 9

    Page 6 - ASTRA/G55 4. When the desired time is display ed, press Button 5 to store. · The r emote will pla y a melody to indicate the alarm clock has been set. T o disable the automatic start / auto activ ate function: 1. Press and hold Buttons 2 and 3 until the remote beeps four times. · The fan and clock will be shown indicating automatic start ...

  • Scytek electronic 1000RS-DBP - page 10

    ASTRA/G55 - Page 7 The PSV or passive function allows the passiv e arming mode to be enabled or with the transmit ter . Note: This feature may not be a vailable on all systems. T o enable or disable the passive arming mode: 1. Press and hold Button 5 until the display shows PSV . · The transmit ter wi ll beep f our times. 2. Release But ton 5. · ...

  • Scytek electronic 1000RS-DBP - page 11

    Page 8 - ASTRA/G55 Remote Arming The system monitors 5 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the S ystem: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking lights will flas ...

  • Scytek electronic 1000RS-DBP - page 12

    ASTRA/G55 - Page 9 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 8 times. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes = door 6 ...

  • Scytek electronic 1000RS-DBP - page 13

    Page 10 - ASTRA/G55 Panic Mode In the event of an emergency the tr ansmitter’s remote P anic feature can be used to instantly trigger the alarm. T o activ ate the Panic Mode: 1. Press and hold Button 1 for fiv e seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock* allowing access to the vehicle. 2. Press B ...

  • Scytek electronic 1000RS-DBP - page 14

    ASTRA/G55 - Page 11 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 6 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, press But ...

  • Scytek electronic 1000RS-DBP - page 15

    Page 12 - ASTRA/G55 Remote Starting T o R emote Start the System: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will flash 4 times and turn on. · The Siren will chirp 4 times. · The engine will start and run for the dur ation of its programmed Run Time.* · The heater or air condi ...

  • Scytek electronic 1000RS-DBP - page 16

    ASTRA/G55 - Page 13 Automatic Start Mode The Automatic Start Mode allows the vehicle to automatically start the vehicle ev ery one or two hours and run for the preset Run Time. T o turn on Auto Starting: 1. T urn Ignition switch Off and w ait for 3 seconds. 2. T urn Ignition switch On and Off three times ending with I gnition in Off position 3. Pre ...

  • Scytek electronic 1000RS-DBP - page 17

    Page 14 - ASTRA/G55 E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking f eature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disabled to prot ...

  • Scytek electronic 1000RS-DBP - page 18

    ASTRA/G55 - Page 15 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit T wo 5-Button R emote T ransmitters (4000RS) One 5-Button & One LCD T wo-W ay T ransmitter (4000RS-2W -1) Siren Shock Sensor Harnesses • 6- Wire starter harness/Relay Module ? ...

  • Scytek electronic 1000RS-DBP - page 19

    Page 16 - ASTRA/G55 Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the oper ation of any vehicle components such as f oot pedals, steering colum ...

  • Scytek electronic 1000RS-DBP - page 20

    ASTRA/G55 - Page 17 S y s t e m W i r i n g 6-Wire Starter Harness Pin 1 RED - A : Main P ower Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 30 Amp supply . R emo v e the f use until the installation is complete and all wiring is checked. Pin 2 RED - B : Main P ower Input B (+). Connect to the batt ...

  • Scytek electronic 1000RS-DBP - page 21

    Page 18 - ASTRA/G55 Pin 13 GRAY : Auxiliary 1 Output (-) 500 mA. Connect to a relay for an optional f eature such as trunk release, etc. This output may be progr ammed for momentary , timed, or latched operation. Pin 14 GREEN/WHITE : Brak e Input (+). Connect to the wire that shows +12V when pressing the brake. The Green/white wire is a safety shut ...

  • Scytek electronic 1000RS-DBP - page 22

    ASTRA/G55 - Page 19 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper f or the correct polarity output as described below , then reassemble the main unit case. Parking Light Output. Selec ...

  • Scytek electronic 1000RS-DBP - page 23

    Page 20 - ASTRA/G55 Entering System Programming The system programming is compatible with both the L CD transmitter or the standard AM tr ansmitter . T o enter S ystem Programming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide three chirps, indicating that you ha ve entered Programming. 3. Pres ...

  • Scytek electronic 1000RS-DBP - page 24

    Branch Feature Button 1 (default) Button 2 Button 3 1. Arm Mode Manual Arming P assive Arming 2. Auto Rearming Mode Disabled Enabled 3. Arming Chirps Siren Chirps On Silent Siren & Horn Chirps On 4. W arn-Away P ager Report Enabled Disabled 5. Extended P arking Lights On Off 6. Ignition Door Locking On Off Set Override Code 7 . Ignition Door Un ...

  • Scytek electronic 1000RS-DBP - page 25

    Page 22 - ASTRA/G55 locking and unlocking. Program to 3 seconds f or v ehicles equipped with v acuum door locking systems. 0.1 seconds for vehicles that roll windows up or down when lock/unlock output is at 1 second. 10. Passive Door Locking. Selects whether or not the system will automatically lock the doors during P assive Arming. 11. Ignore Open ...

  • Scytek electronic 1000RS-DBP - page 26

    ASTRA/G55 - Page 23 RPM Learn. Start the engine, enter Br anch 21 and press Button 1 to learn the v ehicle’ s tach signal. The siren will chirp and the LED will flash once to confirm learning of the tach signal and entering T ach Monitor Mode. The siren will chirp f our times and the LED will flash four times if the tach signal was not learned, e ...

  • Scytek electronic 1000RS-DBP - page 27

    ASTRA/G55 - Page 24 R e l a y D i a g r a m s P ositive Dome Light Activ ation Negative Dome Light Activ ation P ositive Horn Honk Negative Horn Honk Negative Glow Plug Starter Defeat/Anti-Grind ...

  • Scytek electronic 1000RS-DBP - page 28

    Page 25 - ASTRA/G55 Negative T rigger P ositive T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages. D o o r L o c k D i a g r a m s Green Blue ...

  • Scytek electronic 1000RS-DBP - page 29

    ASTRA/G55 - Page 26 T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negative T rigger T wo Stage P ositive T rigger(using inv erter) The ASTRA/G55 can be wired for the P assenger Unlock output feature, allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door . Pre ...

  • Scytek electronic 1000RS-DBP - page 30

    Page 27 - ASTRA/G55 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators Aux 1 output (gray wire) Aux 1 output (gray wire) ...

  • Scytek electronic 1000RS-DBP - page 31

    ASTRA/G55 - Page 28 FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interf erence that may cause undesired operation T e c h n i c a l I n f o r m a t i o n S ...

  • Scytek electronic 1000RS-DBP - page 32

    ScyTek Electronics 11627 Cantara Street North Hollywood, CA 91605 www .scytek.net © ScyT ek Electronics 2010 ASTRA/G55- 6/10/10 W i r i n g D i a g r a m Violet - Starter Out 25 Amp. (+) Red - +12V Battery Input #1 Red - +12V Battery Input #2 Brown - Ignition 2 Output 25 Amp. (+) Yellow- Ignition 1 Out 25 Amp. (+) Orange- Accessory Out 25 Amp. (+) ...

Manufacturer Scytek electronic Category Automobile Alarm

Documents that we receive from a manufacturer of a Scytek electronic 1000RS-DBP can be divided into several groups. They are, among others:
- Scytek electronic technical drawings
- 1000RS-DBP manuals
- Scytek electronic product data sheets
- information booklets
- or energy labels Scytek electronic 1000RS-DBP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Scytek electronic 1000RS-DBP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Scytek electronic 1000RS-DBP, service manual, brief instructions and user manuals Scytek electronic 1000RS-DBP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Scytek electronic 1000RS-DBP.

A complete manual for the device Scytek electronic 1000RS-DBP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Scytek electronic 1000RS-DBP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Scytek electronic 1000RS-DBP.

A complete Scytek electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Scytek electronic 1000RS-DBP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Scytek electronic 1000RS-DBP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Scytek electronic 1000RS-DBP, that we can find in the current document
3. Tips how to use the basic functions of the device Scytek electronic 1000RS-DBP - which should help us in our first steps of using Scytek electronic 1000RS-DBP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Scytek electronic 1000RS-DBP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Scytek electronic 1000RS-DBP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Scytek electronic 1000RS-DBP?

Use the form below

If you did not solve your problem by using a manual Scytek electronic 1000RS-DBP, ask a question using the form below. If a user had a similar problem with Scytek electronic 1000RS-DBP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

Анжела

CLOSE DRAWER