Robertshaw 8625の取扱説明書

12ページ 0.32 mb
ダウンロード

ページに移動 of 12

Summary
  • Robertshaw 8625 - page 1

    1 Application The Robertshaw 8625 is a multi-stage thermostat designed to control 24 V AC heat pump systems. Features • Large back lit display . • Four preprogrammed E NERGY S TA R ® setpoints for each day of the week. • Adjustable 1 st stage temperature differential: 1.0°F to 3.0°F (0.5°C to 1.5°C). • Adjustable 2 nd stage temperature ...

  • Robertshaw 8625 - page 2

    IMPORT ANT SAFETY INFORMA TION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • DO NOT CONNECT TO 120 V AC. This is a 24 V AC low-voltage thermostat. Do not install on voltages hi ...

  • Robertshaw 8625 - page 3

    IMPORT ANT SAFETY INFORMA TION WARNING: In heat pump applications, do not connect anything to the W1 terminal. When switched to HP mode, W1 is connected internally to Y1 on the thermostat. Connect AUX heat to the W2/E terminal. 1. T urn off power to heating and cooling system. 2. Remove cover of old thermostat to expose wires. Do not disconnect wir ...

  • Robertshaw 8625 - page 4

    6. Mark placement of mounting holes (see Figure 3). Set base aside. 7. Drill the marked holes using a 3/16” (5mm) drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening (see Figure 3). 10. Secure base to wall with ...

  • Robertshaw 8625 - page 5

    Wiring Diagrams The following is just a sample of the most common types of HV AC systems. Refer to your system’ s installation manual for wiring information. 5 Hot Heating Control Cooling Control Transformer T H E R M O S T A T W1 C R Y1 G O B 24 VAC 120 VAC Hot Heating Control Fan Control Transformer 24 VAC 120 VAC Hot Heating Control Transforme ...

  • Robertshaw 8625 - page 6

    6 T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V AL VE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAMAGE THE THERMOST A T AND VOID YOUR W ARRANTY . CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERA TURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY . 1. Place the ...

  • Robertshaw 8625 - page 7

    Programming Guide SETTING TIME OF DA Y AND DA Y OF WEEK 1. Press SELECT until the cursor is over SET CLOCK. Press SET . The HOURS segment will be blinking. Use the or button to adjust the time. NOTE: The AM or PM indicator will change as the HOURS display rolls through a 24 hour cycle. 2. Press SET . The MINUTES segment will be blinking. Use the or ...

  • Robertshaw 8625 - page 8

    6. After pressing SET for the 4th event, the day of the week along the top will switch to SA T SUN and AM1 will be displayed. Repeat steps 2-4 to program the weekend settings. 7. With the weekend settings programmed, place the HEA T -OFF-COOL switch in the COOL position. Repeat steps 2-6 to program the cooling settings. CUSTOMIZING THE THERMOST A T ...

  • Robertshaw 8625 - page 9

    6. Press SET . The display will switch to the differential setting for 2 nd stage heating and cooling. 7. The display will read diF2 . Press the or button to adjust the differential up or down. 8. Press SET . The display will switch to the differential delay . 9. The display will read dL Y2 . The differential delay is the length of time (in minutes ...

  • Robertshaw 8625 - page 10

    Another way to select a temporary hold is: 1. Press SELECT until the cursor is over TEMP HOLD. Press SET . The temperature will be blinking. Use the or button to change the temperature. 2. Press SET . T o cancel a temporary hold, press SELECT until the cursor is above RUN/SET PROG. Press SET . Vacation Hold Y ou can set your thermostat to hold a de ...

  • Robertshaw 8625 - page 11

    T roubleshooting Symptom Remedy Thermostat does not turn Check wiring. on system. (See Installing Item 8625 Thermostat ) Thermostat turns on and off too Increase temperature differential. frequently . (See Programming Guide ) System fan does not operate Move the Electric/Gas switch to properly . either gas or electric, to match system. (See Install ...

  • Robertshaw 8625 - page 12

    12 ©2004 Climate Controls Americas 110-1101 Climate Controls Americas 191 E. North Avenue Carol Stream, Illinois 60188 United States of America TWO-YEAR LIMITED W ARRANTY Climate Controls Americas warrants to the original contractor installer or to the original consumer user , each new Robertshaw thermo- stat to be free from defects in materials a ...

メーカー Robertshaw カテゴリー Thermostat

Robertshaw 8625のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 8625の取扱説明書
- Robertshawの製品カード
- パンフレット
- またはRobertshaw 8625の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Robertshaw 8625の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Robertshaw 8625の取り付け説明書、サービスマニュアル、簡易説明書、またはRobertshaw 8625のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Robertshaw 8625の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Robertshaw 8625デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRobertshaw 8625を使用するのを助ける技術的文書のことです。説明書は通常、全てのRobertshaw 8625ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Robertshawの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Robertshaw 8625の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRobertshaw 8625の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Robertshaw 8625に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Robertshaw 8625デバイスの基本機能を使うにあたってのヒント。 Robertshaw 8625のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Robertshaw 8625に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRobertshaw 8625のメーカー/サービスへの連絡先に関する情報。

Robertshaw 8625についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRobertshaw 8625の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRobertshaw 8625で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)