    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: JAN08.0201 © 2008 Zephyr Corporation T wister AK8000AS T ornado I AK8100AS READ AND SA VE THESE INSTRUCTIONS ...

  • Zephyr AK8100AS - page 2

    www .zephyronline.com ...

  • Zephyr AK8100AS - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK8100AS - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK8100AS - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr AK8100AS - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK8000AS AND AK8100AS P ARTS SUPPLIED AK8000AS and AK8100AS 1 - Power Pack 1 - Metal mesh fi lter (AK8000AS), 1 - Decorative mesh fi lter (AK8100AS) 2 - Halogen light bulbs (pre-installed) 1 - Single internal blower (pre-installed) 1 - Hardware package HARDW ARE P ACKAGE CONTENTS P ARTS NOT SUPPLI ...

  • Zephyr AK8100AS - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ...

  • Zephyr AK8100AS - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow effi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Also use calculation (on page 5) to compute total ava ...

  • Zephyr AK8100AS - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK8100AS - page 10

    8 www .zephyronline.com Installation – Specifi cations top front bottom side 4-1/8” 5-3/8” 3-3/4” 10-5/8” 5-7/8” 1-1/16” 10-1/2” 1 1-13/16” 26-9/16” 27-9/16” 27-9/16” 25-3/4” 9-3/8” 8-1 1/16” 1 1-3/16” 1 1-3/16” 10-5/16” 1-5/16” 15” 18-15/16” 10-5/16” 1-1/8” C/L ...

  • Zephyr AK8100AS - page 11

    9 ELECTRICAL W ARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK8100AS - page 12

    10 www .zephyronline.com Installation – Installing the Power Pack 1. Install optional AK08xxAS Stainless Steel Liner . Review manual included with liner for more details. 2. If no liner is used cut out an opening in the bottom of the cabinet by following the dimensions in FIG 1 . 3. Lift Power Pack into opening and ensure locking clip has locked ...

  • Zephyr AK8100AS - page 13

    11 0 I I I I II Blower On/Off Speed Selection 1 Lights Bright/Dim/Off 2 0 I I I Features & Controls – Slide Controls BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. LIGHTS BRIGHT/DIM/OFF 0 is off, I is dim, and II is bright. 1 2 ...

  • Zephyr AK8100AS - page 14

    Maintenance – Cleaning and Installing Filters 12 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier s ...

  • Zephyr AK8100AS - page 15

    Maintenance – AK8000AS Recirculating Kit 13 DUCTLESS RECIRCULA TING (AK8000AS ONL Y): Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the power pack functions in air “purifying” mode rather than exhausting the air . Fumes and exhaust from cooking is drawn and fi ...

  • Zephyr AK8100AS - page 16

    14 www .zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, ...

  • Zephyr AK8100AS - page 17

    T roubleshooting 15 TROUBLESHOOTING PROCEDURES FOR TWISTER AND TORNADO 1 Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power connection ...

  • Zephyr AK8100AS - page 18

    16 www .zephyronline.com DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Metal Mesh Filter (each) 50200022 Decorative Mesh Filter (each) 50200024 Optional Accessories Liner ,30” AK0800AS Liner ,36” AK0836AS Recirculating Kit (AK8000AS ONL Y) ZRC-0100 T o order parts, visit us online at http://store.zephyronline. ...

  • Zephyr AK8100AS - page 19

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

メーカー Zephyr カテゴリー Ventilation Hood

Zephyr AK8100ASのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AK8100ASの取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr AK8100ASの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr AK8100ASの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr AK8100ASの取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr AK8100ASのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr AK8100ASの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr AK8100ASデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr AK8100ASを使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr AK8100ASユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr AK8100ASの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr AK8100ASの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr AK8100ASに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr AK8100ASデバイスの基本機能を使うにあたってのヒント。 Zephyr AK8100ASのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr AK8100ASに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr AK8100ASのメーカー/サービスへの連絡先に関する情報。

Zephyr AK8100ASについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr AK8100ASの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr AK8100ASで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)