ZONEKIT2ZCAR WeatherMaker® Two-Zone Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. TABLE OF CONTENTS PAGE Safety Considerations .....................................................................1 Installation Consideration ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 2
Step 2—Wiring To prevent personal injury or possible equipment damage, disconnect the power supply before routing wire. All wiring must comply with local, state, and national codes. NOTE: Use No. 18 AWG color-coded, insulated (35°C min) wire. If thermostats are to be located more than 100 ft from the WeatherMaker Two-Zone Center as measured alon ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 3
2. Properly seal joint using duct tape, mastic, or other approved method. Do not allow mastic to come in contact with actuator. 3. Insulate damper using 1-1/2-in. to 2-in. insulation. (Check your local codes.) (See Fig. 7.) NOTE: All zone dampers and ductwork must be properly sup- ported according to local codes or SMACNA standards. NOTE: There sho ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 4
Step 5—Install Barometric Bypass Damper NOTE: The barometric bypass damper is a critical part of the WeatherMaker Two-Zone System for control of minimum airflow and noise reduction. It is recommended that the bypass be installed. The bypass should be installed according to local codes and SMACNA standards. Be sure the bypass is properly supported ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 5
In automatic changeover, the zoning system works on a first come first serve basis. If 1 zone is calling for heating and the other for cooling, the zone which sent its demand to the I/O center first will operate the equipment in that mode until that zone is satisfied. Step 5—Duct Temperature Optimizer (DTO) For Monitoring Leaving Air Temperature ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 6
Fig. 12—WeatherMaker Two-Zone Circuit Board with Standard Thermostat Wiring A97293 3 Thermostat Zone 2 Y 2 Y 1 R W 1 W 2 C G Thermostat Zone 1 Y 2 Y 1 R W 1 W 2 C Sensors HP Duct Equipment R c B O Y 2 Y 1 W 1 W 2 G R h 24 VAC Power 24 v CL OP C Zone 1 Damper Zone 2 Damper CL OP C G B D 4 F A E C K J I H L M N 2 3 1 ZONE 1? ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 7
NOTE: An HP temperature sensor must be used with a heat pump application using electric strip heat. This is necessary in case the DTO is set to the Off position. Timeguard The WeatherMaker Two-Zone provides equipment protection with an internal 5-minute timeguard delay. This delay is present upon initial power up. There is also a 5-minute timeguard ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 8
timer will start counting down 15, 14, 13...0 minutes. Once the timer expires the control will allow a new mode to restart the equipment. The internal time, as well as the cooling 5-minute timeguard can be cleared by using the comprotec override feature. CARE AND MAINTENANCE For continuing optimum performance and to minimize possible equipment fail ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 9
TROUBLESHOOTING This section contains information to assist you in troubleshooting problems and errors associated with the WeatherMaker Two-Zone system. See Table 2. Step 1—System Diagram, Jumpers, and Switches NOTE: For correct control board operation, it must have either a sensor attached or a 10k resistor in place at the duct and HP inputs. 1 ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 10
I Red LED—Displays ON when fan is energized. J Red LED—Displays ON when first-stage cooling is energized. K Red LED—Displays ON when second-stage cooling is energized. L Red LED—Displays ON when reversing valve is ener- gized. M Red LED—Displays ON when first-stage heat is energized. N Red LED—Displays ON when second-stage heat is energ ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 11
Table 3 shows a temperature/ohm/voltage relationship to help aid in troubleshooting the WeatherMaker Two-Zone System. This table will evaluate both the Duct/HP temperature sensor operation. Use a digital multimeter to perform the following: To verify a sensor is good, disconnect both leads from the I/O board and measure the resistance through the s ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 12
→ Fig. 17—Typical Fan Coil With Single-Speed Air Conditioner A97298 SINGLE-SPEED AIR CONDITIONER TYPICAL FAN COIL C Y G W2 W3 C R Y/Y2 O L E RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM See notes 1 and 3 * * * * * Y1 * * → Fig. 15—Single-Stage Furnace With Single-Speed Air Conditioner A97296 SINGLE-SPEED AIR COND ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 13
→ Fig. 21—Typical Fan Coil With 2-Speed Air Conditioner A97302 2-SPEED AIR CONDITIONER TYPICAL FAN COIL R G R C W2 Y/Y2 E W3 L O Y1 C Y2 Y1 RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM See notes 1, 2, and 3 * * * * * → Fig. 19—Single-Stage Furnace With 2-Speed Air Conditioner A97300 2-SPEED AIR CONDITIONER SINGLE ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 14
→ Fig. 23—Single-Stage Furnace With Single-Speed Heat Pump A97304 SINGLE-STAGE FURNACE TWO-ZONE SYSTEM INTERFACE CONTROL R GF RF WF R GT E HP O HP OT Y HP C W2 Y O RH G W2 W1 Y1 Y2 O B RC G R W C SINGLE-SPEED HEAT PUMP YT E T C Y 2 1 3 OUTDOOR THERMOST A T (KHAO T0301FST) See notes 4, 5, 6, a ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 15
→ Fig. 27—Single-Stage Furnace With 2-Speed Heat Pump A97308 2-SPEED HEAT PUMP SINGLE-STAGE FURNACE R G R C W Y C Y2 W3 RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM W2 Y1 O See notes 2, 5, 6, 7, 9, 10, and 11 → Fig. 25—Typical Fan Coil With Single-Speed Heat Pump A97306 SINGLE-SPEED HEAT PUMP TWO-ZONE SYSTEM TYPI ...
-
Carrier WEATHERMAKER ZONEKIT2ZCAR - page 16
→ Fig. 29—Typical Fan Coil With 2-Speed Heat Pump A97310 RH G W2 W1 Y1 Y2 O B RC 2-SPEED HEAT PUMP TYPICAL FAN COIL C G W2 Y/Y2 R C W3 L E Y1 R W2 O W3 Y1 Y2 O TWO-ZONE SYSTEM See notes 1, 2, 3, 9, and 11 * * * * * → Fig. 30—FK4C Fan Coil With 2-Speed Heat Pump A97311 FK4C FAN COIL R R G W1 C DH W2 Y1 Y/Y2 O ...